1.
Ann Occup Hyg ; 58(2): 206-16, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24107745

ABSTRACT

National Institute for Occupational Safety and Health (NIOSH) certified particulate respirators need to be properly fit tested before use to ensure workers' respiratory protection. However, the effectiveness of American National Standards Institute-/Occupational Safety and Health Administration (ANSI-/OSHA)-accepted fit tests for particulate respirators in predicting actual workplace protection provided to workers is lacking. NIOSH addressed this issue by evaluating the fit of half-mask particulate filtering respirators as a component of a program designed to add total inward leakage (TIL) requirements for all respirators to Title 42 Code of Federal Regulations Part 84. Specifically, NIOSH undertook a validation study to evaluate the reproducibility of the TIL test procedure between two laboratories. A PortaCount® was used to measure the TIL of five N95 model filtering facepiece respirators (FFRs) on test subjects in two different laboratories. Concurrently, filter efficiency for four of the five N95 FFR models was measured using laboratory aerosol as well as polydisperse NaCl aerosol employed for NIOSH particulate respirator certification. Results showed that two N95 models passed the TIL tests at a rate of ~80-85% and ~86-94% in the two laboratories, respectively. However, the TIL passing rate for the other three N95 models was 0-5.7% in both laboratories combined. Good agreement (≥83%) of the TIL data between the two laboratories was obtained. The three models that had relatively lower filter efficiency for laboratory aerosol as well as for NaCl aerosol showed relatively low TIL passing rates in both laboratories. Of the four models tested for penetration, one model with relatively higher efficiency showed a higher passing rate for TIL tests in both laboratories indicating that filter efficiency might influence TIL. Further studies are needed to better understand the implications of the data in the workplace.


Subject(s)
Air Pollutants, Occupational/analysis , Equipment Failure , Filtration/instrumentation , Inhalation Exposure/prevention & control , Masks/standards , Materials Testing/methods , Respiratory Protective Devices/standards , Aerosols , Equipment Design/standards , Humans , Inhalation Exposure/analysis , National Institute for Occupational Safety and Health, U.S. , Occupational Exposure/prevention & control , Occupational Health , Particle Size , Reproducibility of Results , United States
2.
Ann Occup Hyg ; 57(4): 507-18, 2013 May.
Article in English | MEDLINE | ID: mdl-23258452

ABSTRACT

Previous studies have shown a sampling probe bias for measuring fit factors (FFs) in respirator facepieces. This study was conducted to evaluate three sampling probes for fit testing NIOSH-certified N95 filtering facepiece respirators (FFRs). Two phases of fit test experiments were conducted incorporating 'side-by-side' probe mounting: (i) flush probe versus deep probe and (ii) flush probe versus disc probe. Seven test subjects in Phase 1 and six subjects in Phase 2 were fit tested with one to three N95 FFR models for a total of 10 subject/FFR model combinations for each phase. For each experimental condition, induced faceseal leakage (IFSL) through an induced leak was measured using a PORTACOUNT® Plus model 8020A Respirator Fit Tester with a model 8095 N95-Companion™ accessory. For Phase 1, the mean IFSL of all flush probe measurements (3.6%) was significantly greater than (P < 0.05) the mean IFSL of all deep probe measurements (3.3%). For Phase 2, the mean IFSL of all flush probe measurements (8.5%) was not significantly greater than (P > 0.05) the mean IFSL of all disc probe measurements (8.3%). Results indicate that some leak site and subject/FFR model/leak site combination comparisons (flush probe versus deep probe or flush probe versus disc probe) were statistically different (P < 0.05). The overall mean IFSL for subject/FFR model/leak site combinations differed by 14 and 4% for the flush probe versus deep probe and the flush probe versus disc probe, respectively; however, from a practical standpoint, there is little difference between the flush probe tests compared with the deep probe or disc probe tests. Overall, IFSL measured using the flush probe is higher (resulting in a more conservative measure of faceseal leakage) compared with either the deep probe or disc probe. The more conservative results obtained using the flush probe provide support for its common usage for fit testing cup-shaped FFRs in the USA and potential use for fit testing FFRs in Europe.


Subject(s)
Filtration/instrumentation , Materials Testing/methods , Respiratory Protective Devices/standards , Adolescent , Adult , Equipment Design/standards , Female , Filtration/standards , Humans , Male , Middle Aged , National Institute for Occupational Safety and Health, U.S. , Occupational Exposure/analysis , United States , Young Adult