Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Am Anim Hosp Assoc ; 52(2): 95-101, 2016.
Article in English | MEDLINE | ID: mdl-26808435

ABSTRACT

Nosocomial infections are a growing concern in veterinary hospitals, and identifying fomites is imperative to reducing the risk of pathogen transmission. In veterinary medicine, shaving of hair is necessary prior to many procedures. Contaminated clipper blades have been cited as potential fomites involved in the transmission of pathogens in veterinary and human medicine. The primary goal of this study was to evaluate bacterial contamination of clipper blades in veterinary practices. A secondary goal was to assess whether there was an association between bacterial contamination of clipper blades and clipper blade cleaning solutions, clipper blade cleaning protocols, clipper blade storage, and type of practice. Sixty clipper blades from 60 different practices were cultured. Information regarding blade cleaning solutions, protocols, and storage was collected from each practice. Fifty-one percent (31/60) of clipper blades sampled were contaminated with bacteria. Category of cleaning solutions had a significant association with bacterial contamination (P < 0.02). Cleaning frequency (P = 0.55), storage location (P = 0.26), and practice type (P = 0.06) had no significant association with bacterial contamination. This study documented bacterial contamination of clipper blades in veterinary practices, and clipper blades should be considered potential fomites.


Subject(s)
Bacteria/isolation & purification , Equipment Contamination , Veterinary Medicine/instrumentation , Animals , Cats , Dogs
2.
Vet Dermatol ; 17(2): 147-50, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16515658

ABSTRACT

The objective of this study was to evaluate the relative efficacy of otoscope cone cleaning and disinfection methods commonly used in veterinary practices. Using sterile technique, 60 new gas-sterilized 4-mm otoscope cones were inoculated with a broth culture of 1.5 billion Pseudomonas aeruginosa bacteria per mL then allowed to dry for 10 min. Six study groups of 10 cones each were created. Group 1 served as positive control and received no cleaning or disinfection. Group 2 cones were wiped with sterile cotton-tipped applicators and gauze then rinsed with water. Group 3 cones were wiped with 70% isopropyl alcohol. Group 4 cones were scrubbed in a speculum cleaner with Cetylcide II solution (Cetylite Industries, Inc., Pennsauken, NJ). Groups 5 and 6 cones were soaked for 20 min in Cetylcide II and chlorhexidine gluconate 2% solutions, respectively. Using sterile technique and after 10-15 min drying time, the cones were swabbed in a consistent pattern, and samples were submitted for quantitative culture. Culture results showed no growth from cones soaked in Cetylcide II or chlorhexidine solutions. Two of the 10 cones wiped with alcohol, 3/10 cones wiped then rinsed with water, and 3/10 cones scrubbed with the speculum cleaner showed growth of P. aeruginosa. All (10/10) cones in the control group showed heavy growth of P. aeruginosa. These results show that P. aeruginosa can survive on otoscope cones cleaned and disinfected by several commonly used methods. Further study is needed to determine practical and optimal cleaning and disinfection methods for otoscope cones.


Subject(s)
Disinfection/methods , Otitis Media/veterinary , Otoscopes/veterinary , Animals , California , Case-Control Studies , Equipment Contamination , Humans , Otitis Media/diagnosis , Otoscopes/microbiology , Pilot Projects , Practice Patterns, Physicians'/statistics & numerical data , Pseudomonas aeruginosa/isolation & purification , Veterinary Medicine
SELECTION OF CITATIONS
SEARCH DETAIL
...