Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Orthop Res ; 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38967120

ABSTRACT

Small leucine-rich proteoglycans, such as decorin and biglycan, play pivotal roles in collagen fibrillogenesis during development, healing, and aging in tendon. Previous work has shown that the absence of decorin and biglycan affects fibril shape and mechanical properties during tendon healing. However, the roles of decorin and biglycan in the healing process of aged tendons are unclear. Therefore the objective of this study was to evaluate the differential roles of decorin and biglycan during healing of patellar tendon injury in aged mice. Aged (300 days old) female Dcn+/+/Bgn+/+ control (WT, n = 52), Dcnflox/flox (I-Dcn-/-, n = 36), Bgnflox/flox (I-Bgn-/-, n = 36), and compound Dcnflox/flox/Bgnflox/flox (I-Dcn-/-/Bgn-/-, n = 36) mice with a tamoxifen-inducible Cre were utilized. Targeted gene expression, collagen fibril diameter distributions, mechanical properties, and histological assays were employed to assess the effects of knockdown of decorin and/or biglycan at the time of injury. Knockdown resulted in alterations in fibril diameter distribution and scar area, but surprisingly did not lead to many differences in mechanical properties. Biglycan played a larger role in early healing stages, while decorin is more significant in later stages, particularly in scar remodeling. This study highlights some of the differential roles of biglycan and decorin in the regulation of fibril structure and scar area, as well as influencing gene expression during healing in aged mice.

2.
J Appl Physiol (1985) ; 136(1): 43-52, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-37969085

ABSTRACT

Tendon injury and healing involve intricate changes to tissue metabolism, biology, and inflammation. Current techniques often require animal euthanasia or tissue destruction, limiting assessment of dynamic changes in tendon, including treatment response, disease development, rupture risk, and healing progression. Microdialysis, a minimally invasive technique, offers potential for longitudinal assessment, yet it has not been applied to rat tendon models. Therefore, the objective of this study is to adapt a novel application of an in vivo assay, microdialysis, using acute injury as a model for extreme disruption of the tendon homeostasis. We hypothesize that microdialysis will be able to detect measurable differences in the healing responses of acute injury with high specificity and sensitivity. Overall results suggest that microdialysis is a promising in vivo technique for longitudinal assessment for this system with strong correlations between extracellular fluid (ECF) and dialysate concentrations and reasonable recovery rates considering the limitations of this model. Strong positive correlations were found between dialysate and extracellular fluid (ECF) concentration for each target molecule of interest including metabolites, inflammatory mediators, and collagen synthesis and degradation byproducts. These results suggest that microdialysis is capable of detecting changes in tendon healing following acute tendon injury with high specificity and sensitivity. In summary, this is the first study to apply microdialysis to a rat tendon model and assess its efficacy as a direct measurement of tendon metabolism, biology, and inflammation.NEW & NOTEWORTHY This study adapts a novel application of microdialysis to rat tendon models, offering a minimally invasive avenue for longitudinal tendon assessment. Successfully detecting changes in tendon healing after acute injury, it showcases strong correlations between extracellular fluid and dialysate concentrations. The results highlight the potential of microdialysis as a direct measure of tendon metabolism, biology, and inflammation, bypassing the need for animal euthanasia and tissue destruction.


Subject(s)
Achilles Tendon , Tendon Injuries , Rats , Animals , Achilles Tendon/metabolism , Microdialysis , Tendon Injuries/metabolism , Rupture/metabolism , Rupture/surgery , Dialysis Solutions , Inflammation/metabolism
3.
J Biomech ; 117: 110249, 2021 03 05.
Article in English | MEDLINE | ID: mdl-33486263

ABSTRACT

Rotator cuff tendon tears and tendinopathies are common injuries affecting a large portion of the population and can result in pain and joint dysfunction. Incidence of rotator cuff tears significantly increases with advancing age, and up to 90% of these tears involve the supraspinatus. Previous literature has shown that aging can lead to inferior mechanics, altered composition, and changes in structural properties of the supraspinatus. However, there is little known about changes in supraspinatus mechanical properties in context of other rotator cuff tendons. Alterations in tendon mechanical properties may indicate damage and an increased risk of rupture, and thus, the purpose of this study was to use a rat model to define age-related alterations in rotator cuff tendon mechanics to determine why the supraspinatus is more susceptible to tears due to aging than the infraspinatus, subscapularis, and teres minor. Fatigue, viscoelastic, and quasi-static properties were evaluated in juvenile, adult, aged, and geriatric rats. Aging ubiquitously and adversely affected all rotator cuff tendons tested, particularly leading to increased stiffness, decreased stress relaxation, and decreased fatigue secant and tangent moduli in geriatric animals, suggesting a common intrinsic mechanism due to aging in all rotator cuff tendons. This study demonstrates that aging has a significant effect on rotator cuff tendon mechanical properties, though the supraspinatus was not preferentially affected. Thus, we are unable to attribute the aging-associated increase in supraspinatus tears to its mechanical response alone.


Subject(s)
Rotator Cuff Injuries , Tendon Injuries , Animals , Rats , Rotator Cuff , Rupture , Tendons
4.
J Orthop Res ; 37(1): 94-103, 2019 01.
Article in English | MEDLINE | ID: mdl-30345583

ABSTRACT

Nicotine is harmful to many bodily systems; however, the effects of nicotine on intra-substance tendon healing remain largely unexplored. The purpose of this study was to examine the functional, structural, and biomechanical effects of nicotine on the healing of Achilles tendons in rats after an acute full-thickness injury. Sixty Sprague-Dawley rats were enrolled in this study. Half were exposed to 0.9% saline and half to 61 ng/mL of nicotine for 3 months via subcutaneous osmotic pumps. At 3 months, all rats underwent blunt full thickness transection of the left Achilles tendon and were immobilized for one week in plantarflexion. In-vivo assays were conducted prior to injury, at 21 days, and at 42 days post-injury and included the following: Functional limb assessment, passive joint mechanics, and vascular evaluation. Rats were sacrificed at 21 and 42 days for biomechanical testing and histologic evaluation. Rats exposed to nicotine demonstrated decreased vascularity, greater alteration in gait mechanics, and increased passive ROM of the ankle joint. Biomechanically, the nicotine tendons failed at lower maximum loads, were less stiff, had smaller cross-sectional areas and had altered viscoelastic properties. Histologically, nicotine tendons demonstrated decreased vessel density at the injury site. This study demonstrates that nicotine leads to worse functional outcomes and biomechanical properties in tendons. The decreased vascularity in the nicotine group may suggest an underlying mechanism for inferior tendon healing. Patients should be counseled that using nicotine products increase their risk of poor tendon healing and may predispose them to tendon re-rupture. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.


Subject(s)
Achilles Tendon/drug effects , Ganglionic Stimulants/adverse effects , Nicotine/adverse effects , Regeneration/drug effects , Tendon Injuries , Achilles Tendon/injuries , Achilles Tendon/pathology , Animals , Male , Rats, Sprague-Dawley
5.
Sci Rep ; 8(1): 10854, 2018 Jul 18.
Article in English | MEDLINE | ID: mdl-30022076

ABSTRACT

The extracellular matrix (ECM) is the primary biomechanical environment that interacts with tendon cells (tenocytes). Stresses applied via muscle contraction during skeletal movement transfer across structural hierarchies to the tenocyte nucleus in native uninjured tendons. Alterations to ECM structural and mechanical properties due to mechanical loading and tissue healing may affect this multiscale strain transfer and stress transmission through the ECM. This study explores the interface between dynamic loading and tendon healing across multiple length scales using living tendon explants. Results show that macroscale mechanical and structural properties are inferior following high magnitude dynamic loading (fatigue) in uninjured living tendon and that these effects propagate to the microscale. Although similar macroscale mechanical effects of dynamic loading are present in healing tendon compared to uninjured tendon, the microscale properties differed greatly during early healing. Regression analysis identified several variables (collagen and nuclear disorganization, cellularity, and F-actin) that directly predict nuclear deformation under loading. Finite element modeling predicted deficits in ECM stress transmission following fatigue loading and during healing. Together, this work identifies the multiscale response of tendon to dynamic loading and healing, and provides new insight into microenvironmental features that tenocytes may experience following injury and after cell delivery therapies.


Subject(s)
Extracellular Matrix/pathology , Stress, Mechanical , Tendon Injuries/pathology , Tendon Injuries/therapy , Tendons/physiology , Wound Healing , Animals , Female , Mice , Mice, Inbred C57BL , Plastic Surgery Procedures
6.
Ann Biomed Eng ; 45(8): 2025-2035, 2017 08.
Article in English | MEDLINE | ID: mdl-28409291

ABSTRACT

The objective of this study was to examine the ability of 3D implants with trabecular-bone-inspired porosity and micro-/nano-rough surfaces to enhance vertical bone ingrowth. Porous Ti-6Al-4V constructs were fabricated via laser-sintering and processed to obtain micro-/nano-rough surfaces. Male and female human osteoblasts were seeded on constructs to analyze cell morphology and response. Implants were then placed on rat calvaria for 10 weeks to assess vertical bone ingrowth, mechanical stability and osseointegration. All osteoblasts showed higher levels of osteocalcin, osteoprotegerin, vascular endothelial growth factor and bone morphogenetic protein 2 on porous constructs compared to solid laser-sintered controls. Porous implants placed in vivo resulted in an average of 3.1 ± 0.6 mm3 vertical bone growth and osseointegration within implant pores and had significantly higher pull-out strength values than solid implants. New bone formation and pull-out strength was not improved with the addition of demineralized bone matrix putty. Scanning electron images and histological results corroborated vertical bone growth. This study indicates that Ti-6Al-4V implants fabricated by additive manufacturing to have porosity based on trabecular bone and post-build processing to have micro-/nano-surface roughness can support vertical bone growth in vivo, and suggests that these implants may be used clinically to increase osseointegration in challenging patient cases.


Subject(s)
Bone Development/physiology , Osteoblasts/cytology , Osteoblasts/physiology , Osteogenesis/physiology , Titanium/chemistry , Alloys , Cells, Cultured , Equipment Failure Analysis , Female , Heating/methods , Humans , Lasers , Male , Materials Testing , Porosity , Powders , Prosthesis Design , Surface Properties , Titanium/radiation effects , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...