1.
BMJ Case Rep ; 13(6)2020 Jun 21.
Article in English | MEDLINE | ID: mdl-32565435

ABSTRACT

We present a case of split and partially entwined sciatic nerve by a femoral prosthesis following closed reduction of a dislocated hip replacement. This complication is very rare and there are only few cases reported in the literature, with even less accompanied by supporting MRI. We present MRI features of a split and partially entwined sciatic nerve around a hip prosthesis.


Subject(s)
Arthroplasty, Replacement, Hip/adverse effects , Hip Prosthesis/adverse effects , Postoperative Complications/etiology , Prosthesis Failure/adverse effects , Sciatic Neuropathy/etiology , Aged , Arthroplasty, Replacement, Hip/methods , Female , Hip Dislocation/surgery , Humans , Magnetic Resonance Imaging , Medical Illustration , Sciatic Nerve