Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
IEEE Trans Neural Netw Learn Syst ; 33(7): 2853-2866, 2022 07.
Article in English | MEDLINE | ID: mdl-33434136

ABSTRACT

Real-time in situ image analytics impose stringent latency requirements on intelligent neural network inference operations. While conventional software-based implementations on the graphic processing unit (GPU)-accelerated platforms are flexible and have achieved very high inference throughput, they are not suitable for latency-sensitive applications where real-time feedback is needed. Here, we demonstrate that high-performance reconfigurable computing platforms based on field-programmable gate array (FPGA) processing can successfully bridge the gap between low-level hardware processing and high-level intelligent image analytics algorithm deployment within a unified system. The proposed design performs inference operations on a stream of individual images as they are produced and has a deeply pipelined hardware design that allows all layers of a quantized convolutional neural network (QCNN) to compute concurrently with partial image inputs. Using the case of label-free classification of human peripheral blood mononuclear cell (PBMC) subtypes as a proof-of-concept illustration, our system achieves an ultralow classification latency of 34.2 [Formula: see text] with over 95% end-to-end accuracy by using a QCNN, while the cells are imaged at throughput exceeding 29 200 cells/s. Our QCNN design is modular and is readily adaptable to other QCNNs with different latency and resource requirements.


Subject(s)
Leukocytes, Mononuclear , Neural Networks, Computer , Algorithms , Humans , Image Processing, Computer-Assisted/methods , Software
2.
BMC Bioinformatics ; 21(1): 45, 2020 Feb 05.
Article in English | MEDLINE | ID: mdl-32024475

ABSTRACT

BACKGROUND: Current popular variant calling pipelines rely on the mapping coordinates of each input read to a reference genome in order to detect variants. Since reads deriving from variant loci that diverge in sequence substantially from the reference are often assigned incorrect mapping coordinates, variant calling pipelines that rely on mapping coordinates can exhibit reduced sensitivity. RESULTS: In this work we present GeDi, a suffix array-based somatic single nucleotide variant (SNV) calling algorithm that does not rely on read mapping coordinates to detect SNVs and is therefore capable of reference-free and mapping-free SNV detection. GeDi executes with practical runtime and memory resource requirements, is capable of SNV detection at very low allele frequency (<1%), and detects SNVs with high sensitivity at complex variant loci, dramatically outperforming MuTect, a well-established pipeline. CONCLUSION: By designing novel suffix-array based SNV calling methods, we have developed a practical SNV calling software, GeDi, that can characterise SNVs at complex variant loci and at low allele frequency thus increasing the repertoire of detectable SNVs in tumour genomes. We expect GeDi to find use cases in targeted-deep sequencing analysis, and to serve as a replacement and improvement over previous suffix-array based SNV calling methods.


Subject(s)
Genetic Variation , Genome , Neoplasms/genetics , Software , Algorithms , Gene Frequency , High-Throughput Nucleotide Sequencing , Humans , Whole Genome Sequencing
3.
Sci Rep ; 7: 44608, 2017 03 17.
Article in English | MEDLINE | ID: mdl-28303936

ABSTRACT

Based on image encoding in a serial-temporal format, optical time-stretch imaging entails a stringent requirement of state-of-the-art fast data acquisition unit in order to preserve high image resolution at an ultrahigh frame rate - hampering the widespread utilities of such technology. Here, we propose a pixel super-resolution (pixel-SR) technique tailored for time-stretch imaging that preserves pixel resolution at a relaxed sampling rate. It harnesses the subpixel shifts between image frames inherently introduced by asynchronous digital sampling of the continuous time-stretch imaging process. Precise pixel registration is thus accomplished without any active opto-mechanical subpixel-shift control or other additional hardware. Here, we present the experimental pixel-SR image reconstruction pipeline that restores high-resolution time-stretch images of microparticles and biological cells (phytoplankton) at a relaxed sampling rate (≈2-5 GSa/s)-more than four times lower than the originally required readout rate (20 GSa/s) - is thus effective for high-throughput label-free, morphology-based cellular classification down to single-cell precision. Upon integration with the high-throughput image processing technology, this pixel-SR time-stretch imaging technique represents a cost-effective and practical solution for large scale cell-based phenotypic screening in biomedical diagnosis and machine vision for quality control in manufacturing.


Subject(s)
Image Processing, Computer-Assisted/methods , Nanoparticles/ultrastructure , Phytoplankton/ultrastructure , Algorithms , Flow Cytometry , Phantoms, Imaging , Water/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...