Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
2.
Psychiatry Res ; 317: 114856, 2022 11.
Article in English | MEDLINE | ID: mdl-36155277

ABSTRACT

We examined the safety and efficacy of repetitive Transcranial Magnetic Stimulation (rTMS) of the right orbitofrontal cortex (OFC) in patients with refractory obsessive-compulsive disorder (OCD) and comorbid Major Depressive Disorder. All participants (n = 26) received excitatory stimulation of the left dorsolateral prefrontal cortex followed by inhibitory stimulation of bilateral supplementary motor area for 10 sessions. In 18 patients with poor early OCD response, treatment was augmented with OFC inhibitory stimulation after the tenth treatment session. Augmentation with OFC stimulation was well-tolerated, and associated with further alleviation of both OCD and depression symptoms, particularly in individuals with more severe illnesses.


Subject(s)
Depressive Disorder, Major , Motor Cortex , Obsessive-Compulsive Disorder , Humans , Transcranial Magnetic Stimulation , Depressive Disorder, Major/complications , Depressive Disorder, Major/therapy , Prefrontal Cortex , Obsessive-Compulsive Disorder/complications , Obsessive-Compulsive Disorder/therapy , Treatment Outcome
3.
Trop Med Infect Dis ; 6(3)2021 Sep 04.
Article in English | MEDLINE | ID: mdl-34564547

ABSTRACT

X-ray screening is an important tool in tuberculosis (TB) prevention and care, but access has historically been restricted by its immobile nature. As recent advancements have improved the portability of modern X-ray systems, this study represents an early evaluation of the safety, image quality and yield of using an ultra-portable X-ray system for active case finding (ACF). We reported operational and radiological performance characteristics and compared image quality between the ultra-portable and two reference systems. Image quality was rated by three human readers and by an artificial intelligence (AI) software. We deployed the ultra-portable X-ray alongside the reference system for community-based ACF and described TB care cascades for each system. The ultra-portable system operated within advertised specifications and radiologic tolerances, except on X-ray capture capacity, which was 58% lower than the reported maximum of 100 exposures per charge. The mean image quality rating from radiologists for the ultra-portable system was significantly lower than the reference (3.71 vs. 3.99, p < 0.001). However, we detected no significant differences in TB abnormality scores using the AI software (p = 0.571), nor in any of the steps along the TB care cascade during our ACF campaign. Despite some shortcomings, ultra-portable X-ray systems have significant potential to improve case detection and equitable access to high-quality TB care.

SELECTION OF CITATIONS
SEARCH DETAIL
...