ABSTRACT

This study is inspired by the widely used algorithm for real-time optical flow, the sparse Lucas-Kanade, by applying a feature extractor to decrease the computational requirement of optical flow based neural networks from real-world thermal aerial imagery. Although deep-learning-based algorithms have achieved state-of-the-art accuracy and have outperformed most traditional techniques, most of them cannot be implemented on a small multi-rotor UAV due to size and weight constraints on the platform. This challenge comes from the high computational cost of these techniques, with implementations requiring an integrated graphics processing unit with a powerful on-board computer to run in real time, resulting in a larger payload and consequently shorter flight time. For navigation applications that only require a 2D optical flow vector, a dense flow field computed from a deep learning neural network contains redundant information. A feature extractor based on the Shi-Tomasi technique was used to extract only appropriate features from thermal images to compute optical flow. The state-of-the-art RAFT-s model was trained with a full image and with our proposed alternative input, showing a substantial increase in speed while maintain its accuracy in the presence of high thermal contrast where features could be detected.

2.
J Imaging ; 8(4)2022 Apr 16.
Article in English | MEDLINE | ID: mdl-35448243

ABSTRACT

It is necessary to establish the relative performance of established optical flow approaches in airborne scenarios with thermal cameras. This study investigated the performance of a dense optical flow algorithm on 14 bit radiometric images of the ground. While sparse techniques that rely on feature matching techniques perform very well with airborne thermal data in high-contrast thermal conditions, these techniques suffer in low-contrast scenes, where there are fewer detectable and distinct features in the image. On the other hand, some dense optical flow algorithms are highly amenable to parallel processing approaches compared to those that rely on tracking and feature detection. A Long-Wave Infrared (LWIR) micro-sensor and a PX4Flow optical sensor were mounted looking downwards on a drone. We compared the optical flow signals of a representative dense optical flow technique, the Image Interpolation Algorithm (I2A), to the Lucas-Kanade (LK) algorithm in OpenCV and the visible light optical flow results from the PX4Flow in both X and Y displacements. The I2A to LK was found to be generally comparable in performance and better in cold-soaked environments while suffering from the aperture problem in some scenes.

3.
J Imaging ; 7(10)2021 Oct 19.
Article in English | MEDLINE | ID: mdl-34677303

ABSTRACT

Limited navigation capabilities of many current robots and UAVs restricts their applications in GPS denied areas. Large aircraft with complex navigation systems rely on a variety of sensors including radio frequency aids and high performance inertial systems rendering them somewhat resistant to GPS denial. The rapid development of computer vision has seen cameras incorporated into small drones. Vision-based systems, consisting of one or more cameras, could arguably satisfy both size and weight constraints faced by UAVs. A new generation of thermal sensors is available that are lighter, smaller and widely available. Thermal sensors are a solution to enable navigation in difficult environments, including in low-light, dust or smoke. The purpose of this paper is to present a comprehensive literature review of thermal sensors integrated into navigation systems. Furthermore, the physics and characteristics of thermal sensors will also be presented to provide insight into challenges when integrating thermal sensors in place of conventional visual spectrum sensors.

4.
J Imaging ; 7(2)2021 Feb 05.
Article in English | MEDLINE | ID: mdl-34460627

ABSTRACT

The World Health Organization (WHO) has declared COVID-19 a pandemic. We review and reduce the clinical literature on diagnosis of COVID-19 through symptoms that might be remotely detected as of early May 2020. Vital signs associated with respiratory distress and fever, coughing, and visible infections have been reported. Fever screening by temperature monitoring is currently popular. However, improved noncontact detection is sought. Vital signs including heart rate and respiratory rate are affected by the condition. Cough, fatigue, and visible infections are also reported as common symptoms. There are non-contact methods for measuring vital signs remotely that have been shown to have acceptable accuracy, reliability, and practicality in some settings. Each has its pros and cons and may perform well in some challenges but be inadequate in others. Our review shows that visible spectrum and thermal spectrum cameras offer the best options for truly noncontact sensing of those studied to date, thermal cameras due to their potential to measure all likely symptoms on a single camera, especially temperature, and video cameras due to their availability, cost, adaptability, and compatibility. Substantial supply chain disruptions during the pandemic and the widespread nature of the problem means that cost-effectiveness and availability are important considerations.