Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Front Immunol ; 13: 975533, 2022.
Article in English | MEDLINE | ID: mdl-36248883

ABSTRACT

Background: COVID-19 has caused a global pandemic and the death toll is increasing. With the coronavirus continuously mutating, Omicron has replaced Delta as the most widely reported variant in the world. Studies have shown that the plasma of some vaccinated people does not neutralize the Omicron variant. However, further studies are needed to determine whether plasma neutralizes Omicron after one- or two-dose vaccine in patients who have recovered from infection with the original strain. Methods: The pseudovirus neutralization assays were performed on 64 plasma samples of convalescent COVID-19 patients, which were divided into pre-vaccination group, one-dose vaccinated group and two-dose vaccinated group. Results: In the three groups, there were significant reductions of sera neutralizing activity from WT to Delta variant (B.1.617.2), and from WT to Omicron variant (B.1.1.529) (ps<0.001), but the difference between Delta and Omicron variants were not significant (p>0.05). The average neutralization of the Omicron variant showed a significant difference between pre-vaccination and two-dose vaccinated convalescent individuals (p<0.01). Conclusions: Among the 64 plasma samples of COVID-19 convalescents, whether vaccinated or not, Omicron (B.1.1.529) escaped the neutralizing antibodies, with a significantly decreased neutralization activity compared to WT. And two-dose of vaccine could significantly raise the average neutralization of Omicron in convalescent individuals.


Subject(s)
COVID-19 , Viral Vaccines , Antibodies, Neutralizing , Antibodies, Viral , COVID-19/prevention & control , Humans , Neutralization Tests , SARS-CoV-2
2.
J Clin Virol ; 130: 104576, 2020 09.
Article in English | MEDLINE | ID: mdl-32763810

ABSTRACT

BACKGROUND: The unsatisfactory accuracy and capacity of real time RT-PCR depends on several unavoidable reasons, which cannot meet the demands for COVID-19 diagnosis. METHODS: 206 serum samples were collected from patients who were treated in the General Hospital of the Central Theater Command of the PLA between January 18 and April 4, 2020. 270 serum samples from healthy blood donors were used as control. IgM and total antibodies (Ab) against SARS-CoV-2 were detected by Chemiluminescence Microparticle Immunoassay (CMIA). RESULTS: Among the 206 patients, the positive rate of IgM and Ab were 149/206 (72.3 %) and 187/206 (90.8 %), respectively. And the specificity of IgM and Ab detection were 99.3 % and 98.9 %, respectively. The sensitivity of CMIA for Ab detection was significantly higher than that of IgM. An increase of the positive rate and S/CO value for detecting IgM and Ab accompanied with the increasing of days post-disease onset (d.p.o.) were observed. The positive rate of Ab detected by CMIA increased rapidly after 7 d.p.o., while that of IgM was obviously increased after 14 d.p.o.. In addition, the age and gender of these patients did not affect the seroconversion and titer of antibodies during the whole course. The disease-severity of patients had no effect on the seroconversion of antibodies. However, the critical patients possessed a much higher antibody titers than the no-critical cases after 14 d.p.o.. CONCLUSIONS: The CMIA can provide important complementation to nucleic acid assay and help to enhance the accuracy and capacity of diagnosis of SARS-CoV-2 infection.


Subject(s)
Antibodies, Viral/blood , Clinical Laboratory Techniques/methods , Coronavirus Infections/diagnosis , Immunoassay/methods , Pneumonia, Viral/diagnosis , Adult , Aged , Betacoronavirus , COVID-19 , COVID-19 Testing , COVID-19 Vaccines , Coronavirus Infections/immunology , Female , Humans , Immunoglobulin G/blood , Immunoglobulin M/blood , Luminescent Measurements , Male , Middle Aged , Pandemics , Pneumonia, Viral/immunology , SARS-CoV-2 , Sensitivity and Specificity , Seroconversion
3.
Microbes Infect ; 22(4-5): 206-211, 2020.
Article in English | MEDLINE | ID: mdl-32425648

ABSTRACT

In this study, we aimed to evaluate the diagnostic value of serological assay for SARS-CoV-2. A newly-developed ELISA assay for IgM and IgG antibodies against N protein of SARS-CoV-2 was used to screen the serums of 238 admitted hospital patients between February 6 and February 14, 2020 with confirmed or suspected SARS-CoV-2. SARS-CoV-2 RNA was detected on pharyngeal swab specimens using real time RT-PCR. 194 (81.5%) of the serums were detected to be antibody (IgM and/or IgG) positive, significantly higher than the positive rate of viral RNA (64.3%). There was no difference in the positive rate of antibodies between the confirmed patients (83.0%, 127/153) and the suspected patients (78.8%, 67/85), whose nucleic acid tests were negative. The antibody positive rates were very low in the first five days after initial onset of symptoms, and then rapidly increased as the disease progressed. After 10 days, the antibody positive rates jumped from below 50% to over 80%. However, the positive rates of viral RNA maintained above 60% in the first 11 days after initial onset of symptoms, and then rapidly decreased. Overall, the suspected patients were most likely infected by SARS-CoV-2. Before the 11th day after initial onset of symptoms, nucleic acid test is key for confirmation of viral infection. The combination of serological assay can greatly improve the diagnostic efficacy. After the 11th day post-disease onset, the diagnosis for viral infection should be majorly dependent on serological assay.


Subject(s)
Antibodies, Viral/blood , Betacoronavirus , Coronavirus Infections/diagnosis , Coronavirus Infections/virology , Inpatients , Pneumonia, Viral/diagnosis , Pneumonia, Viral/virology , Serologic Tests , Adult , Aged , COVID-19 , Enzyme-Linked Immunosorbent Assay , Female , Humans , Immunoglobulin G/blood , Immunoglobulin M/blood , Male , Middle Aged , Pandemics , RNA, Viral/blood , SARS-CoV-2
4.
J Clin Microbiol ; 58(6)2020 05 26.
Article in English | MEDLINE | ID: mdl-32229605

ABSTRACT

At present, PCR-based nucleic acid detection cannot meet the demands for coronavirus infectious disease (COVID-19) diagnosis. Two hundred fourteen confirmed COVID-19 patients who were hospitalized in the General Hospital of Central Theater Command of the People's Liberation Army between 18 January and 26 February 2020 were recruited. Two enzyme-linked immunosorbent assay (ELISA) kits based on recombinant severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleocapsid protein (rN) and spike protein (rS) were used for detecting IgM and IgG antibodies, and their diagnostic feasibility was evaluated. Among the 214 patients, 146 (68.2%) and 150 (70.1%) were successfully diagnosed with the rN-based IgM and IgG ELISAs, respectively; 165 (77.1%) and 159 (74.3%) were successfully diagnosed with the rS-based IgM and IgG ELISAs, respectively. The positive rates of the rN-based and rS-based ELISAs for antibody (IgM and/or IgG) detection were 80.4% and 82.2%, respectively. The sensitivity of the rS-based ELISA for IgM detection was significantly higher than that of the rN-based ELISA. We observed an increase in the positive rate for IgM and IgG with an increasing number of days post-disease onset (d.p.o.), but the positive rate of IgM dropped after 35 d.p.o. The positive rate of rN-based and rS-based IgM and IgG ELISAs was less than 60% during the early stage of the illness, 0 to 10 d.p.o., and that of IgM and IgG was obviously increased after 10 d.p.o. ELISA has a high sensitivity, especially for the detection of serum samples from patients after 10 d.p.o., so it could be an important supplementary method for COVID-19 diagnosis.


Subject(s)
Betacoronavirus/immunology , Clinical Laboratory Techniques/methods , Coronavirus Infections/immunology , Coronavirus Infections/virology , Enzyme-Linked Immunosorbent Assay/methods , Pneumonia, Viral/immunology , Pneumonia, Viral/virology , Spike Glycoprotein, Coronavirus/immunology , COVID-19 , COVID-19 Testing , Coronavirus Infections/diagnosis , Humans , Immunoglobulin G/blood , Immunoglobulin G/immunology , Immunoglobulin M/blood , Immunoglobulin M/immunology , Pandemics , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL
...