Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
Forensic Sci Int ; 291: 44-52, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30138750

ABSTRACT

Most traditional techniques to recover latent fingermarks from metallic surfaces do not consider the metal surface properties and instead focus on the fingermark chemistry. The scanning Kelvin probe (SKP) technique is a non-contact, non-destructive method, used under ambient conditions, which can be utilised to recover latent prints from metallic surfaces and does not require any enhancement techniques or prevent subsequent forensic analysis. Where a fingermark ridge contacted the metal, the contact potential difference (CPD) contrast between the background surface and the fingermark contact area was 10-50mV. Measurements were performed on the untreated brass, nickel-coated brass and copper metal surfaces and compared to traditional forensic enhancement techniques such as Vacuum Metal Deposition (VMD) using Au-Zn and Au-Ag. Using VMD, the CPD change ranged from 0 to 150mV between the dissimilar metal surfaces affected by the fingermark. In general, SKP worked best without additional enhancement techniques. Scanning Electron Microscope (SEM) scans were used to identify the fingermark contact areas through a sodium, chlorine and oxygen electron probe micro-analyzer (EPMA). The fingermark was observed in the backscattered electron image as the carbon deposits scattered the electrons less than the surrounding metal surface. The fingermark is shown clearly in a Cathodoluminescence scan on the copper sample as it blocks the photon emission at band gap (2.17eV) from the underlying copper oxide (Cu2O) surface. For the first time, SEM, EPMA and Cathodoluminescence techniques were compared to SKP data. Visible and latent fingermarks were tested with latent, eccrinous fingermarks more easily imaged by SKP. Results obtained were very encouraging and suggest that the scanning Kelvin probe technique, which does not need vacuum, could have a place as a first stage analysis tool in serious crime investigation.


Subject(s)
Dermatoglyphics , Metals, Heavy , Microscopy, Electron, Scanning , Microscopy/methods , Forensic Medicine/instrumentation , Forensic Medicine/methods , Humans , Microscopy/instrumentation , Surface Properties
2.
Forensic Sci Int ; 273: 88-95, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28249217

ABSTRACT

This paper describes the use of atomic force microscopy (AFM) to investigate the interactions between explosives crystals and different surfaces. Crystals of TNT, PETN and RDX were mounted onto tipless AFM cantilevers and repeatedly brought into contact with a range of surfaces (n=15), including textile and non-textile surfaces. The adhesion force during each contact was measured, and the results are presented in this work. The results suggest that explosives crystals display a higher adhesion to smoother, non-textile surfaces, particularly glass. This finding may be of use for forensic explosives investigators when deciding the best types of debris to target for explosives recovery.

3.
Talanta ; 164: 716-726, 2017 Mar 01.
Article in English | MEDLINE | ID: mdl-28107996

ABSTRACT

Explosives residues in soils may be a useful source of evidence following the detonation of an improvised explosive device (IED), such as a vehicle-borne IED. Soil samples collected from the vicinity of an explosion scene will often be stored for some time prior to analysis, yet explosives residues in soil samples are susceptible to rapid degradation or transformation. Although some research has assessed the use of different storage temperatures with a view to reducing explosives' degradation over time, further research examining the degradation of explosives in soil when stored under a variety of storage conditions is crucial to determine the optimal sample collection and storage procedures for soil containing explosives residues. In this work, three different soils were spiked with solutions of TNT, RDX and PETN and stored either at room temperature, refrigerated or frozen. Samples were extracted over 6 weeks, with additional samples gamma-irradiated or nitrogen purged prior to storage. Experimental results indicate that TNT underwent very rapid degradation at room temperature, attributed to microbial action, whereas PETN and RDX proved to be more stable. Gamma irradiation and nitrogen purging proved of some benefit for mitigating TNT degradation, with lower storage temperatures ultimately proving the most effective method of mitigating degradation.

4.
Forensic Sci Int ; 264: 82-8, 2016 07.
Article in English | MEDLINE | ID: mdl-27037663

ABSTRACT

For most fires, forensic investigation takes place well after building materials have cooled and knowledge of the structural damage due to heat exposure can reveal the temperature reached during an incident. Recently, there have been significant changes in the types and hence characteristics of cementitious materials used in the United Arab Emirates. Few studies focus on the application of thermo-analytical, X-ray diffraction and petrographic techniques on newly developed structures and this work aims to address this deficiency by utilising a series of parametric laboratory-based tests to assess the effects of heat on hardened concrete. Specimens were made with a design mix typically used for low-rise residential homes and storage facilities. The key constituents were: Portland cement (PC), crushed gabbro stone and dune sand with water/cement ratios of 0.4-0.5. Portland cement substitutes included ground granulated blast-furnace slag (GGBS), and silica fume (SF) at replacement percentages of up to 50% and 4%, respectively. The concrete cubes of 100-mm size were produced and standard cured to 28 days and then exposed to heat inside an electric furnace with pre-determined temperature regimes of 150°C, 300°C, 600°C and 900°C. Petrographic examination was utilised to compare the discolouration of the cooled concrete. Data derived from thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC) are reported in order to assess the usefulness of these techniques in fire scene investigation to differentiate between these temperature regimes. The results from the TGA indicate that the majority of the percentage weight loss for all the mixtures occurred in the range 650-700°C, which corresponds to the decarbonation of calcium carbonate, mainly from the aggregates. The endothermic DSC peak at 70-120°C relates to the loss of evaporable water. Since both of these reactions are irreversible, this information can help fire investigators estimate the temperature history of concrete after exposure to fire. On the other hand, the portlandite in the cement matrix dehydroxylates at 450-550°C but then reforms as the concrete cools. The onset temperature for the dehydroxylation of the reformed mineral is always lower than in virgin samples and its enthalpy furthermore depends strongly on the thermal history of the portlandite. Thus, this feature can be used to establish the temperature to which the material was exposed to during a fire incident.

5.
Sci Justice ; 54(1): 71-80, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24438781

ABSTRACT

Hyperspectral imaging (HSI) is a useful technique in the examination of writing inks, including gel pen inks, which combines digital imaging with % reflectance spectroscopy. This facilitates the detection of subtle differences between chemically similar inks. This study analysed a variety of blue, red and black gel inks on white office paper using HSI. The potential of the technique for ink discrimination compared to other analytical methods of examination is highlighted. Discriminating powers of 1.00, 0.90 and 0.40 were achieved using HSI for red, blue and black gel inks respectively. The overall discriminating power of 0.76 for the technique combined with its non-destructive nature and minimal sampling requirements demonstrates promise for this type of application.

6.
Sci Justice ; 49(1): 1, 2009 Mar.
Article in English | MEDLINE | ID: mdl-19418920
7.
Forensic Sci Int ; 181(1-3): 1-9, 2008 Oct 25.
Article in English | MEDLINE | ID: mdl-18938051

ABSTRACT

The Electrostatic Detection Apparatus (ESDA) is a technique most commonly used for the visualisation of indented impressions on questioned documents. This work investigates some of the variables which are known to affect the results of ESDA and some variables which have, as yet, not been addressed. The investigation of variables included: examining the effects of different levels of indentation on different qualities of paper, chronological aging of cascade developer and the effects of repeated use of cascade developer on both the quality of results and the glass beads themselves, the effects of storage of cascade developer in a humidified environment and finally the effects of variation on the image development time. Results indicate that chronological aging of cascade developer does not have a negative effect on the quality of results and a 200 g portion of cascade developer will give good quality results for up to 30 traces before the quality will begin to deteriorate. Humidification of the cascade developer appears to have no advantages over storage in a normal environment and, in fact, the toner is lost sooner with humidification. The surface of the glass beads are affected through repeated use of cascade developer and appear to become visually smoother which may lead to a loss of attraction between them and the toner particles.

8.
Sci Justice ; 46(2): 63, 2006.
Article in English | MEDLINE | ID: mdl-17002207
9.
11.
Forensic Sci Int ; 91(2): 153-61, 1998 Jan 30.
Article in English | MEDLINE | ID: mdl-9549905

ABSTRACT

It is suggested that persons arrested and incarcerated for sexual offences are in some ways different than other inmates. This paper examines various characteristics of sexual offenders in an Irish prison and determines if perceived differences are statistically valid using some of the techniques available through offender profiling. Statistical differences (chi 2; P = 0.01) in some characteristics were found between other prisoners and sexual offenders.


Subject(s)
Data Interpretation, Statistical , Prisoners/statistics & numerical data , Sex Offenses/statistics & numerical data , Adolescent , Adult , Age Distribution , Criminal Psychology , Health Status , Humans , Ireland , Male , Marital Status , Middle Aged , Prisoners/psychology , Risk Factors , Sex Offenses/psychology , Socioeconomic Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...