Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Article in English | MEDLINE | ID: mdl-38744354

ABSTRACT

Left ventricular assist devices (LVADs) are excellent therapies for advanced heart failure patients either bridged to transplant or for lifetime use. LVADs also allow for reverse remodeling of the failing heart that is often associated with functional improvement. Indeed, growing enthusiasm exists to better understand this population of patients, whereby the LVAD is used as an adjunct to mediate myocardial recovery. When patients achieve benchmarks suggesting that they no longer need LVAD support, questions related to the discontinuation of LVAD therapy become front and center. The purpose of this review is to provide a surgical perspective on the practical and technical issues surrounding LVAD deactivation.

2.
Ann Thorac Surg ; 117(2): 466-472, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37271443

ABSTRACT

BACKGROUND: In academic surgery publications, self-reporting of conflicts of interest (COI) has often proved to be inaccurate. Here, we review the accuracy of COI disclosures for studies related to the use of robotic technology in cardiothoracic surgery and evaluate factors associated with increased discrepancies. METHODS: A literature search identified robotic surgery-related studies with at least 1 American author published between January 2015 and December 2020 from 3 major American cardiothoracic surgery journals (The Journal of Thoracic and Cardiovascular Surgery, The Annals of Thoracic Surgery, and Annals of Cardiothoracic Surgery). Industry payments from Intuitive Surgical (Intuitive) were collected with use of the Centers for Medicare and Medicaid Open Payments database. COI discrepancies were identified by comparing author declaration statements with payments found for the year of publication and the year prior (24-month period). RESULTS: A total of 144 studies (764 authors) were identified. At least 1 author of 112 studies (78%) had received payments from Intuitive. At least 1 author of 98 studies (68%) had received an undeclared payment from Intuitive. Authors who accurately disclosed payments received significantly higher median payments compared with authors who did not ($16,511 [interquartile range, $6389-$159,035] vs $1762 [interquartile range, $338-$7500]; P < .0001). Last authors were significantly more likely to have a COI discrepancy compared with middle and first authors (P = .018; P = .0015). CONCLUSIONS: Most studies investigating the use of robotic technology in cardiothoracic surgery did not accurately declare COI with Intuitive. This study highlights the need for improved accuracy of reporting industry sponsorship by publishing authors.


Subject(s)
Robotic Surgical Procedures , Aged , Humans , United States , Conflict of Interest , Medicare , Disclosure , Industry
3.
J Surg Res ; 292: 222-233, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37657140

ABSTRACT

INTRODUCTION: Heart transplantation is the treatment of choice for end-stage heart failure. There is a mismatch between the number of donor hearts available and the number of patients awaiting transplantation. Expanding the donor pool is critically important. The use of hearts donated following circulatory death is one approach to increasing the number of available donor hearts. MATERIALS AND METHODS: A systematic review was performed according to the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines utilizing Pubmed/MEDLINE and Embase. Articles including adult human studies and preclinical animal studies of heart transplantation following donation after circulatory death were included. Studies of pediatric populations or including organs other than heart were excluded. RESULTS: Clinical experience and preclinical studies are reviewed. Clinical experience with direct procurement, normothermic regional perfusion, and machine perfusion are included. Preclinical studies addressing organ function assessment and enhancement of performance of marginal organs through preischemic, procurement, preservation, and reperfusion maneuvers are included. Articles addressing the ethical considerations of thoracic transplantation following circulatory death are also reviewed. CONCLUSIONS: Heart transplantation utilizing organs procured following circulatory death is a promising method to increase the donor pool and offer life-saving transplantation to patients on the waitlist living with end-stage heart failure. There is robust ongoing preclinical and clinical research to optimize this technique and improve organ yield. There are also ongoing ethical considerations that must be addressed by consensus before wide adoption of this approach.

4.
Thorac Surg Clin ; 30(3): 259-267, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32593359

ABSTRACT

Enhanced recovery pathways (ERPs), used across multiple surgical subspecialties, is a multidisciplinary delivery of perioperative care designed to lessen the psychological stress of patients undergoing surgery. Thoracic ERP has been implemented but is not widespread, and variations exist between programs. Evidence of the benefit of thoracic ERP is emerging. This article presents common components of a thoracic surgery ERP and reviews contemporary outcomes.


Subject(s)
Perioperative Care , Rehabilitation/methods , Thoracic Surgical Procedures/rehabilitation , Antibiotic Prophylaxis , Atrial Fibrillation/prevention & control , Early Ambulation , Humans , Nutrition Therapy , Postoperative Complications/prevention & control , Venous Thrombosis/prevention & control
5.
Am J Transplant ; 19(2): 597-600, 2019 02.
Article in English | MEDLINE | ID: mdl-30063120

ABSTRACT

Pulmonary masses occasionally occur after lung transplantation and vary in etiology, which includes malignant and benign conditions, such as infection. Here, we report a case of a patient presenting with a lung mass 3 years after lung transplant. To our knowledge, this is the first described case of pulmonary malakoplakia due to Rhodococcus equi infection in an allograft post-lung transplantation. This case outlines the challenges of differentiating benign from malignant masses after transplantation.


Subject(s)
Actinomycetales Infections/complications , Lung Diseases/diagnosis , Lung Neoplasms/diagnosis , Lung Transplantation/adverse effects , Malacoplakia/diagnosis , Postoperative Complications , Rhodococcus equi/isolation & purification , Actinomycetales Infections/epidemiology , Actinomycetales Infections/microbiology , Aged , Diagnosis, Differential , Humans , Lung Diseases/etiology , Lung Neoplasms/etiology , Malacoplakia/etiology , Male , Prognosis
SELECTION OF CITATIONS
SEARCH DETAIL
...