Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Reconstr Microsurg ; 38(9): 694-702, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35292952

ABSTRACT

BACKGROUND: Nerve wrapping has been advocated to minimize scarring and adhesion following neurorrhaphy or neurolysis. A wrap should provide an enclosure that is snug enough to protect and support the affected nerve without strangulating the nerve. The degree to which resorbable wraps should be ": tightened" around the nerve is largely subjective with scant literature on the subject. The purpose of this study was to evaluate the effects of tightly fitting resorbable nerve wraps around intact rat sciatic nerves. METHODS: Twenty-four Sprague-Dawley rats underwent exposure and circumferential measurement of the right sciatic nerve. Porcine-derived extracellular matrix (ECM) wraps were trimmed and sutured to enclose the nerve with a tight (same as that of the nerve, n = 8) or loose (2.5x that of the nerve, n = 8) circumference. Sham-surgery control animals (n = 8) had no wrap treatment. Functional outcome was recorded biweekly by sciatic functional index (SFI) with walking track analysis and electrical stimulation. Animals were sacrificed at 12 weeks for histologic analyses. RESULTS: No withdrawal response could be evoked in the tight-wrap group until week 9, while significant improvement in SFI first occurred between weeks 5 and 7. By week 12, the tight-wrap group required 60% more current compared with baseline stimulation to produce a withdrawal response. They recovered 81% of SFI baseline values but also demonstrated significantly greater intraneural collagen content (p < 0.001) and lower axon density (p < 0.05) than in the loose-wrap and sham groups. The loose-wrap group had comparable functional and histologic outcomes to the sham control group. CONCLUSION: Resorbable ECM nerve wraps applied tightly around intact rat sciatic nerves caused significant functional impairment and histological changes characteristic of acute nerve compression. Significant but incomplete functional recovery was achieved by the tight-wrap group after 12 weeks, but such recovery may not apply in humans.


Subject(s)
Peripheral Nerve Injuries , Sciatic Nerve , Humans , Rats , Swine , Animals , Rats, Sprague-Dawley , Sciatic Nerve/surgery , Sciatic Nerve/pathology , Peripheral Nerve Injuries/pathology , Axons/pathology , Recovery of Function/physiology , Nerve Regeneration/physiology
2.
J Reconstr Microsurg ; 36(7): 501-506, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32303102

ABSTRACT

BACKGROUND: End-to-side (ETS) anastomoses are necessary for many procedures in microvascular surgery, such as free flap transfers. In training courses that use the rat model, the arterial end to venous side (AEVS) anastomosis is a common training exercise for ETS anastomoses. Surgeons-in-training often inadvertently twist the artery when completing the AEVS anastomosis; however, in the clinical setting, torsion is a reported risk factor for ETS anastomosis failure. The purpose of this study was to determine if torsion in an AEVS anastomosis would have a negative effect on patency in the rat model, accurately simulating the clinical scenario. METHODS: All AEVS anastomoses were completed in 15 Sprague-Dawley rats divided into three torsion cohorts: 0, 90, and 180 degrees. Torsion was created in the AEVS anastomosis by mismatching the first two sutures placed between the free femoral artery end and the venotomy. Patency was verified at 0, 2, and 4 hours postoperation via the oxygenated-deoxygenated test and transit-time ultrasound blood flow measurements. RESULTS: All AEVS anastomoses were patent 0, 2, and 4 hours postoperation according to both the oxygenated-deoxygenated test and transit-time ultrasound blood flow measurements. For the average blood flow measurements at 4 hours postoperation, the proximal measurements for 0, 90, and 180 degrees were -34.3, -18.7, and -13.8 mL/min respectively, and the distal measurements were 4.48, 3.46, and 2.90 mL/min, respectively. CONCLUSION: Torsion of 180 degrees does not affect early AEVS anastomosis patency in the rat model. This contrasts with the clinical setting, where torsion is reported to cause ETS anastomosis failure. Since AEVS anastomosis torsion is often difficult to appreciate visually, we suggested that microvascular surgery training instructors include a method to both detect and prevent AEVS anastomosis torsion, such as by marking the free femoral artery end with a marking pen or suture before beginning the anastomosis.


Subject(s)
Microsurgery , Veins , Anastomosis, Surgical , Animals , Femoral Artery/surgery , Rats , Rats, Sprague-Dawley , Vascular Patency , Veins/surgery
3.
J Reconstr Microsurg ; 36(7): 486-493, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32303103

ABSTRACT

BACKGROUND: Successful microvascular anastomosis depends on sutures that adequately oppose both cut vessel edges. Trainees tend to take oversized or uneven bite. To improve early microsurgical skill acquisition using the rat, this study tests the belief that such bites compromise early patency by applying exaggerated bites to end-to-end arterial anastomoses. METHODS: Twelve Sprague-Dawley rats were randomly assigned to one of the four bite techniques to be applied to both femoral arteries (mean diameter, 0.8 mm). Large (L) and standard (S) bites measured 1.0 and 0.2 mm from the edge, respectively. Eight simple interrupted anastomoses were performed per bite technique, each labeled according to every proximal end bite size, followed by every distal end bite size: LL, LS, SL, and SS. Anastomosis time and blood flow rates were recorded and analyzed statistically. After sacrifice 5 days postoperation, anastomosis sections of each technique were examined histologically. RESULTS: All 24 anastomoses (100%) maintained patency for 5 days. There was no statistical difference between all postoperative blood flow measurements at any given time. Anastomosis times using LL, LS, SL, and SS bite techniques were 41.6, 33.2, 34.8, and 25.5 minutes, respectively. Anastomosis time for the traditional bite technique (SS) was significantly shorter than all other bite techniques (p < 0.05). Histological examination of the harvested segments from each group revealed similar pathophysiological features. CONCLUSION: Oversized bites (1 mm), placed symmetrically and asymmetrically across the anastomosis, do not affect early patency in the rat femoral artery. A reduced reliance on conventional guidelines for suture bites appears acceptable during microarterial anastomoses if the goal is vessel patency. However, we believe clinical competence involves the ability to place small, even bites consistently and uniformly. During microsurgical training, the occasional large bite need not be replaced; however, the trainee should be encouraged to take standard bites.


Subject(s)
Femoral Artery , Suture Techniques , Anastomosis, Surgical , Animals , Femoral Artery/surgery , Microsurgery , Rats , Rats, Sprague-Dawley , Vascular Patency
4.
Ann Plast Surg ; 85(S1 Suppl 1): S129-S134, 2020 07.
Article in English | MEDLINE | ID: mdl-32205493

ABSTRACT

BACKGROUND: Lymphedema is a frequent complication after surgical treatments of cancer involving lymph node resection. However, research of lymphedema treatments, such as vascularized lymph node transfer, is limited by the absence of an adequate lymphedema animal model. The purpose of this study was to determine if we could create sustainable lower limb lymphedema in the rat with a combination of inguinal lymphadenectomy, circumferential skin and subcutaneous tissue excision, and radiotherapy. METHODS: Inguinal lymphadenectomies were completed in 15 Sprague-Dawley rats. In cohort A, 5 rats received a 0.5- to 1.0-cm wide excision of proximal thigh skin and subcutaneous tissue. This step was omitted for the 10 rats in cohort B. Cohort A then received a single radiation dose of 22.7 Gy, whereas cohort B received a cumulative dose of 40.5 Gy. Bioimpedance measurements were obtained monthly to assess lymphedema progression, and lymphatic drainage at 6 months postradiation was visualized via indocyanine green (ICG) lymphangiography. RESULTS: Two rats in cohort A developed visually appreciable lymphedema in the lower limb, with bioimpedance ratios of 0.684 and 0.542 and ankle circumference ratios of 1.294 and 1.061, respectively, consistent with lymphedema. Furthermore, ICG lymphangiography in these cohort A rats revealed impaired lower limb lymphatic drainage. In cohort B, however, bioimpedance and circumference ratios, and ICG lymphangiography, did not reveal abnormal lymphatic drainage. CONCLUSIONS: The combination of inguinal lymphadenectomy, circumferential skin and subcutaneous tissue excision, and radiotherapy can successfully create lower limb lymphedema in the rat. When soft tissue excision is omitted, lymphedema does not develop.


Subject(s)
Lymphatic Vessels , Lymphedema , Animals , Lower Extremity , Lymph Node Excision , Lymphedema/etiology , Lymphedema/surgery , Rats , Rats, Sprague-Dawley
SELECTION OF CITATIONS
SEARCH DETAIL
...