Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
PLoS One ; 19(5): e0303740, 2024.
Article in English | MEDLINE | ID: mdl-38748639

ABSTRACT

Acute kidney injury (AKI) is a sudden loss of renal function with a high mortality rate and inflammation is thought to be the underlying cause. The phenylpropanoid components acteoside (ACT) and isoacteoside (ISO), which were isolated from Cistanche deserticola Y.C.Ma, have been reported to have preventive effects against kidney disorders. This study aimed to investigate the anti-inflammatory properties and protective mechanisms of ACT and ISO. In this investigation, kidney function was assessed using a semi-automatic biochemical analyzer, histopathology was examined using Hematoxylin-Eosin staining and immunohistochemistry, and the concentration of inflammatory cytokines was assessed using an enzyme-linked immunosorbent assay (ELISA) test. In addition, using Western blot and q-PCR, the expression of proteins and genes connected to the NF-κB signaling pathway in mice with lipopolysaccharide (LPS)-induced AKI was found. The findings showed that under AKI intervention in LPS group, ACT group and ISO group, the expression of Rela (Rela gene is responsible for the expression of NFκB p65 protein) and Tlr4 mRNA was considerably elevated (P<0.01), which led to a significant improvement in the expression of MyD88, TLR4, Iκ-Bɑ and NF-κB p65 protein (P<0.001). The levels of Alb, Crea and BUN (P<0.001) increased along with the release of downstream inflammatory factors such as IL-1ß, IL-6, Cys-C, SOD1 and TNF-α (P<0.001). More importantly, the study showed that ISO had a more favorable impact on LPS-induced AKI mice than ACT. In conclusion, by inhibiting NF-κB signaling pathway, ACT and ISO could relieve renal failure and inflammation in AKI, offering a fresh possibility for the therapeutic management of the condition.


Subject(s)
Acute Kidney Injury , Glucosides , Inflammation , Lipopolysaccharides , NF-kappa B , Phenols , Signal Transduction , Animals , Acute Kidney Injury/chemically induced , Acute Kidney Injury/drug therapy , Acute Kidney Injury/metabolism , Acute Kidney Injury/pathology , Signal Transduction/drug effects , Glucosides/pharmacology , Glucosides/therapeutic use , Mice , NF-kappa B/metabolism , Male , Phenols/pharmacology , Inflammation/drug therapy , Inflammation/pathology , Inflammation/metabolism , Kidney/drug effects , Kidney/pathology , Kidney/metabolism , Toll-Like Receptor 4/metabolism , Toll-Like Receptor 4/genetics , Cytokines/metabolism , Transcription Factor RelA/metabolism
2.
Zhongguo Zhong Yao Za Zhi ; 47(5): 1286-1292, 2022 Mar.
Article in Chinese | MEDLINE | ID: mdl-35343156

ABSTRACT

This study discovered that the resolution of 3,5-O-dicaffeoylquinic acid(isochlorogenic acid A) in the content determination method of Chrysanthemi Flos in Chinese Pharmacopoeia(ChP)(2020 edition) was poor, which affected accurate quantification. We tested the method in ChP with chromatographic columns of seven brands to clarify the problems in the existing method, optimized the chromatographic conditions by adjusting the mobile phase composition and elution ratio and replacing the chromatographic column packing, and carried out the reproducibility assay for the new method. The two methods were compared for the content determination results of Chrysanthemi Flos prepared from six different varieties. As evaluated by the resolution based on different chromatographic columns of seven brands, the existing method failed to separate isochlorogenic acid A and isochlorogenic acid D well. The peaks of the two components were not completely separated on three chromatographic columns, and isochlorogenic acid A and isochlorogenic acid D generated a co-effluent peak in the other four columns. Isochlorogenic acid A and isochlorogenic acid D could be completely separated under the optimized chromatographic conditions. The difference in the peak areas of isochlorogenic acid A+isochlorogenic acid D obtained by the optimized method and the method in ChP was not significant, with deviation less than 3.0%, which further proved that the result measured by the method in ChP was the co-effluent of isochlorogenic acid A and isochlorogenic acid D. The optimized method can ensure the accurate quantification of isochlorogenic acid A. The existing content determination method of Chrysanthemi Flos has the problem of poor resolution. It is recommended to revise the chromatographic conditions for the content determination method of Chrysanthemi Flos to improve the resolution of isochlorogenic acid A and ensure its accurate quantification.


Subject(s)
Drugs, Chinese Herbal , China , Chromatography, High Pressure Liquid/methods , Drugs, Chinese Herbal/chemistry , Flowers/chemistry , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...