Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 97
Filter
1.
Talanta ; 257: 124366, 2023 May 15.
Article in English | MEDLINE | ID: mdl-36863294

ABSTRACT

Food allergies are hypersensitivity immune responses triggered by (traces of) allergenic compounds in foods and drinks. The recent trend towards plant-based and lactose-free diets has driven an increased consumption of plant-based milks (PBMs) with the risk of cross-contamination of various allergenic plant-based proteins during the food manufacturing process. Conventional allergen screening is usually performed in the laboratory, but portable biosensors for on-site screening of food allergens at the production site could improve quality control and food safety. Here, we developed a portable smartphone imaging surface plasmon resonance (iSPR) biosensor composed of a 3D-printed microfluidic SPR chip for the detection of total hazelnut protein (THP) in commercial PBMs and compared its instrumentation and analytical performance with a conventional benchtop SPR. The smartphone iSPR shows similar characteristic sensorgrams compared with the benchtop SPR and enables the detection of trace levels of THP in spiked PBMs with the lowest tested concentration of 0.625 µg/mL THP. The smartphone iSPR achieved LoDs of 0.53, 0.16, 0.14, 0.06, and 0.04 µg/mL THP in 10x-diluted soy, oat, rice, coconut, and almond PBMs, respectively, with good correlation with the conventional benchtop SPR system (R2 0.950-0.991). The portability and miniaturized characteristics of the smartphone iSPR biosensor platform make it promising for the future on-site detection of food allergens by food producers.


Subject(s)
Biosensing Techniques , Food Hypersensitivity , Humans , Surface Plasmon Resonance/methods , Allergens , Smartphone , Biosensing Techniques/methods , Limit of Detection , Food Hypersensitivity/diagnosis
2.
Anal Chem ; 95(2): 1395-1401, 2023 01 17.
Article in English | MEDLINE | ID: mdl-36547121

ABSTRACT

Despite mass spectrometry (MS) being proven powerful for the characterization of synthetic polymers, its potential for the analysis of single particle microplastics (MPs) is yet to be fully disclosed. To date, MPs are regarded as ubiquitous contaminants, but the limited availability of techniques that enable full characterizations of MPs results in a lack of systematic data regarding their occurrence. In this study, an atmospheric solid analysis probe (ASAP) coupled to a compact quadrupole MS is proposed for the chemical analysis of single particle microplastics, while maintaining full compatibility with complementary staining and image analysis approaches. A two-stage ASAP probe temperature program was optimized for the removal of additives and surface contaminants followed by the actual polymer characterization. The method showed specific mass spectra for a wide range of single particle MPs, including polyolefins, polyaromatics, polyacrylates, (bio)polyesters, polyamides, polycarbonates, and polyacrylonitriles. The single particle size detection limits for polystyrene MPs were found to be 30 and 5 µm in full scan and selected ion recording mode, respectively. Moreover, results are presented of a multimodal microplastic analysis approach in which filtered particles are first characterized by staining and fluorescence microscopy, followed by simple probe picking of individual particles for subsequent analysis by ASAP-MS. The method provides a full characterization of MP contamination, including particle number, particle size, particle shape, and chemical identity. The applicability of the developed multimodal method was successfully demonstrated by the analysis of MPs in bioplastic bottled water.


Subject(s)
Microplastics , Water Pollutants, Chemical , Microplastics/analysis , Plastics/chemistry , Gas Chromatography-Mass Spectrometry , Water Pollutants, Chemical/analysis , Mass Spectrometry , Environmental Monitoring
3.
J Am Soc Mass Spectrom ; 33(11): 2038-2045, 2022 Nov 02.
Article in English | MEDLINE | ID: mdl-36223493

ABSTRACT

The lack of chromatographic separation in ambient and direct mass spectrometry (MS) ionization techniques jeopardizes the overall selectivity of the developed methods. Incorporating a biosensing element at the ionization source could compensate for that inherent lack of selectivity. Thus, a simplified immunoaffinity-direct MS technique was developed, immunoaffinity blade spray (iBS), featuring a conductive polystyrene blade material. In iBS, the generic coating used in conventional coated blade spray is replaced with a layer of highly specific monoclonal antibodies (mAbs), while the stainless steel is replaced with conductive polystyrene to allow for simple ELISA platelike hydrophobic immobilization of mAbs. Because of its high relevance for climate change-induced food safety issues, the mycotoxin deoxynivalenol (DON) was chosen as a model substance. Following a rapid extraction from wheat flour, DON is immuno-captured, and the blade is positioned in front of the MS for direct iBS-MS/MS analysis. The method's applicability was demonstrated by analyzing spiked and incurred wheat flour samples, omitting the need for time-consuming chromatographic separation. Apart from DON, cross-reacting DON conjugates could be successfully analyzed as well. The direct iBS-MS/MS method is generic and adaptable to detecting any analyte in sample extracts, provided that specific mAbs are available.


Subject(s)
Food Contamination , Tandem Mass Spectrometry , Antibodies, Monoclonal , Flour/analysis , Plastics , Polystyrenes , Tandem Mass Spectrometry/methods , Triticum/chemistry , Food Contamination/analysis
4.
Biosensors (Basel) ; 12(3)2022 Feb 22.
Article in English | MEDLINE | ID: mdl-35323408

ABSTRACT

The use of peptides in immunoassays can be favored over the use of the full protein when more cost effective or less toxic approaches are needed, or when access to the full protein is lacking. Due to restricted access to recombinant bovine somatotropin (rbST), a protein enhancing growth and lactating performances of livestock, which use has been banned in the EU, Canada and Australia (amongst others), we developed a peptide-based biorecognition assay on an imaging planar array analyzer. For this, we identified the rbST epitope that is responsible for binding to the rbST-targeting monoclonal antibody 4H12 (MAb 4H12) to be 115DLEEGILALMR125. This linear peptide was synthesized and coupled to microspheres, after which it was tested in a biorecognition competitive inhibition assay format. We observed IC50 values of approximately 0.11 µg mL-1, which are lower than observed for the full rbST protein (IC50 = 0.20 µg mL-1). Importantly, there was no binding with the scrambled peptide. Preliminary results of directly coupled peptides in a microsphere biorecognition assay for detection of rbST are presented. Real-life applicability for detection of somatotropins (STs) in injection preparations of bovine-, porcine- and equine ST are shown. This newly developed immunoassay strongly supports future developments of peptide-based immunoassays to circumvent the limited access to the full protein.


Subject(s)
Growth Hormone , Lactation , Animals , Cattle , Female , Growth Hormone/pharmacology , Horses , Immunoassay/methods , Microspheres , Recombinant Proteins , Swine
5.
Anal Bioanal Chem ; 414(11): 3459-3470, 2022 May.
Article in English | MEDLINE | ID: mdl-35220465

ABSTRACT

Due to the absence of chromatographic separation, ambient ionization mass spectrometry had the potential to improve the throughput of control laboratories in the last decades and will soon be an excellent approach for on-site use as well. In this study, an atmospheric solids analysis probe (ASAP) with a single quadrupole mass analyzer has been evaluated to identify anabolic steroid esters rapidly. Sample introduction, applied scan time, and probe temperature were optimized for sensitivity. The in-source fragmentations of seventeen selected steroid esters, commonly found in illicit samples, were determined by applying different cone voltages (12, 20, 30, and 40 V). A spectral library was created for these steroid esters based on the four stages of in-source fragmentation spectra. The applicability of this method was demonstrated for the rapid identification of steroid esters in oily injection solutions, providing test results in less than 2 min.


Subject(s)
Anabolic Agents , Esters , Anabolic Agents/analysis , Mass Spectrometry , Steroids/analysis , Testosterone Congeners
6.
Anal Chem ; 93(47): 15736-15743, 2021 11 30.
Article in English | MEDLINE | ID: mdl-34726384

ABSTRACT

Paramagnetic microspheres can be used in planar array fluorescence immunoassays for single or multiplex screening of food contaminants. However, no confirmation of the molecular identity is obtained. Coated blade spray (CBS) is a direct ionization mass spectrometry (MS) technique, and when combined with triple quadrupole MS/MS, it allows for rapid confirmation of food contaminants. The lack of chromatography in CBS, though, compromises the specificity of the measurement for unequivocal identification of contaminants, based on the European Union (EU) regulation. Therefore, a rapid and easy-to-use immuno-magnetic blade spray (iMBS) method was developed in which immuno-enriched paramagnetic microspheres replace the coating of CBS. The iMBS-MS/MS method was fully optimized, validated in-house following the EU 2021/808 regulation, and benchmarked against a commercial lateral flow immunoassay (LFIA) for on-site screening of DA. The applicability of iMBS-MS/MS was further demonstrated by analyzing incurred mussel samples. The combination of immunorecognition and MS/MS detection in iMBS-MS/MS enhances the measurement's selectivity, which is demonstrated by the rapid differentiation between the marine toxin domoic acid (DA) and its structural analog kainic acid (KA), which cannot be achieved with the LFIA alone. Interestingly, this first-ever reported iMBS-MS/MS method is generic and can be adapted to include any other immuno-captured food contaminant, provided that monoclonal antibodies are available, thus offering a complementary confirmatory analysis approach to multiplex immunoassay screening methods. Moreover, thanks to its speed of analysis, iMBS-MS/MS can bridge the logistics gap between future large-scale on-site testings using LFIAs and classical time-consuming confirmatory MS analysis performed in official control laboratories.


Subject(s)
Bivalvia , Tandem Mass Spectrometry , Animals , Kainic Acid/analogs & derivatives , Magnetic Phenomena , Microspheres
7.
Foods ; 10(6)2021 Jun 17.
Article in English | MEDLINE | ID: mdl-34204284

ABSTRACT

Standard methods for chemical food safety testing in official laboratories rely largely on liquid or gas chromatography coupled with mass spectrometry. Although these methods are considered the gold standard for quantitative confirmatory analysis, they require sampling, transferring the samples to a central laboratory to be tested by highly trained personnel, and the use of expensive equipment. Therefore, there is an increasing demand for portable and handheld devices to provide rapid, efficient, and on-site screening of food contaminants. Recent technological advancements in the field include smartphone-based, microfluidic chip-based, and paper-based devices integrated with electrochemical and optical biosensing platforms. Furthermore, the potential application of portable mass spectrometers in food testing might bring the confirmatory analysis from the laboratory to the field in the future. Although such systems open new promising possibilities for portable food testing, few of these devices are commercially available. To understand why barriers remain, portable food analyzers reported in the literature over the last ten years were reviewed. To this end, the analytical performance of these devices and the extent they match the World Health Organization benchmark for diagnostic tests, i.e., the Affordable, Sensitive, Specific, User-friendly, Rapid and Robust, Equipment-free, and Deliverable to end-users (ASSURED) criteria, was evaluated critically. A five-star scoring system was used to assess their potential to be implemented as food safety testing systems. The main findings highlight the need for concentrated efforts towards combining the best features of different technologies, to bridge technological gaps and meet commercialization requirements.

8.
Toxins (Basel) ; 13(6)2021 05 21.
Article in English | MEDLINE | ID: mdl-34064219

ABSTRACT

In recent years, conjugated mycotoxins have gained increasing interest in food safety, as their hydrolysis in human and animal intestines leads to an increase in toxicity. For the production of zearalenone (ZEN) glycosides reference standards, we applied Cunninghamellaelegans and Cunninghamella echinulata fungal strains. A sulphate-depleted medium was designed for the preferred production of ZEN glycosides. Both Cunninghamella strains were able to produce zearalenone-14-ß-D-glucopyranoside (Z14G), zearalenone-16-ß-D-glucopyranoside (Z16G) and zearalenone-14-sulphate (Z14S). In a rich medium, Cunninghamellaelegans preferably produced Z14S, while Cunninghamellaechinulata preferably produced Z14G. In the sulphate-depleted medium a dramatic change was observed for Cunninghamellaelegans, showing preferred production of Z14G and Z16G. From 2 mg of ZEN in sulphate-depleted medium, 1.94 mg of Z14G and 0.45 mg of Z16G were produced. Following preparative Liquid Chromatography-Mass Spectrometry (LC-MS) purification, both fractions were submitted to 1H and 13C NMR and High-Resolution Mass Spectrometry (HRMS). These analyses confirmed that the purified fractions were indeed Z14G and Z16G. In conclusion, the presented research shows that a single Cunninghamella strain can be an effective and efficient tool for the controlled biotransformation of ZEN glycosides and other ZEN metabolites. Additionally, the biotransformation method was extended to zearalanone, ß-zearalenol and other mycotoxins.


Subject(s)
Cunninghamella/metabolism , Glycosides/biosynthesis , Zearalenone/metabolism , Biotransformation , Chromatography, Liquid , Cunninghamella/chemistry , Magnetic Resonance Spectroscopy , Mass Spectrometry , Zearalenone/chemistry
9.
Anal Chem ; 93(23): 8122-8127, 2021 06 15.
Article in English | MEDLINE | ID: mdl-34077188

ABSTRACT

A hand-held laser diode thermal desorption electrospray ionization (LDTD-ESI) mass spectrometry (MS) method was developed for rapid screening of illegal substances in solid samples. To achieve that, a simple, inexpensive, battery-powered surgical laser diode at 940 nm was employed to ablate the solid samples. The potential of using a black polytetrafluoroethylene substrate to enhance the analytes' desorption to the gas phase was investigated and demonstrated. Among the optimized ESI parameters, the solvent (methanol/water, 50:50, v/v) and the flow rate (50 µL h-1) were critical to obtain the best sensitivity. The applicability was demonstrated for the rapid identification of selective androgen receptor modulators (SARMs) in pills and powders based on accurate mass measurements by time-of-flight MS. Also, the hand-held LDTD-ESI was combined with a transportable single quadrupole MS. The same SARMs samples were analyzed, and identifications were based on in-source cone voltage fragmentation patterns observed. These initial results demonstrate the applicability of the developed simplified LDTD-ESI MS method for future on-site testing of organic compounds in solid samples.


Subject(s)
Lasers, Semiconductor , Tandem Mass Spectrometry , Spectrometry, Mass, Electrospray Ionization
10.
Sensors (Basel) ; 21(5)2021 Mar 07.
Article in English | MEDLINE | ID: mdl-33800036

ABSTRACT

In current food safety monitoring, lateral flow immunoassays (LFIAs) are widely used for rapid food contaminant screening. Recent advances include smartphone readouts, offering semi-quantitative analysis of LFIAs with time, location, and data transfer in case of on-site testing. Following the screening, the next step in the EU regulations is confirmation by, e.g., liquid chromatography-tandem mass spectrometry (LC-MS/MS). In this work, using direct analysis in real time ambient ionization and triple quadrupole MS/MS (DART-QqQ-MS/MS), we achieved rapid confirmation of the identity of the substance(s) causing the LFIA result. In the workflow proposed, an individual performs the (on-site) smartphone LFIA screening, and when the result is suspect, an identification LFIA (ID-LFIA) strip is developed with the same sample extract. The ID-LFIA can be dissociated and rapidly analyzed in a control laboratory with DART-QqQ-MS/MS. The ID-LFIA consists of multiple lines of monoclonal antibodies against the mycotoxin deoxynivalenol, acting as a bioaffinity trap. The ID-LFIA/DART-QqQ-MS/MS approach has been developed and validated, along with the screening smartphone LFIA, and has demonstrated its applicability by analyzing incurred and spiked samples. The developed approach has been critically compared with our previous direct electrospray ionization MS method and was found to provide highly complementary information on the total deoxynivalenol contamination in the sample.


Subject(s)
Immunoassay , Smartphone , Tandem Mass Spectrometry , Chromatography, Liquid , Trichothecenes/analysis
11.
J Dairy Sci ; 104(4): 5069-5078, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33663857

ABSTRACT

The elimination of recombinant bovine somatotropin (rbST) and its induced antibodies through milk of 2 formulations is studied to propose a control strategy for its use or abuse. Two dairy cows were treated with alanine-rbST (Ala-rbST), which is identical to endogenous bovine somatotropin, and ten dairy cows were treated with methionine-rbST (Met-rbST), which differs by 1 amino acid from endogenous bovine somatotropin. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method able to measure rbST at a decision limit (CCα) of 0.8 ng/mL and 2.3 ng/mL for serum and milk, respectively. The results show that the administered Ala-rbST is transferred from blood to milk but that this is not the case for Met-rbST. This suggests a blood-milk barrier-related specificity for these compounds. In addition, rbST-induced antibodies were formed in animals treated with Ala-rbST and those treated with Met-rbST. In both treatments, the rbST-induced antibodies were transferred from blood to milk, showing no blood-milk barrier specificity for these antibodies. These elimination patterns show that, for enforcement purposes, the detection of rbST-induced antibodies in tank milk can serve to screen for rbST administration, and subsequent confirmatory serum analysis by LC-MS/MS is needed to identify whether Ala-rbST or Met-rbST has been used.


Subject(s)
Methionine , Milk , Alanine , Animals , Cattle , Chromatography, Liquid/veterinary , Female , Growth Hormone , Recombinant Proteins , Tandem Mass Spectrometry/veterinary
12.
Sci Rep ; 11(1): 4920, 2021 03 01.
Article in English | MEDLINE | ID: mdl-33649376

ABSTRACT

A novel, integrated, in vitro gastrointestinal (GI) system is presented to study oral bioavailability parameters of small molecules. Three compartments were combined into one hyphenated, flow-through set-up. In the first compartment, a compound was exposed dynamically to enzymatic digestion in three consecutive microreactors, mimicking the processes of the mouth, stomach, and intestine. The resulting solution (chyme) continued to the second compartment, a flow-through barrier model of the intestinal epithelium allowing absorption of the compound and metabolites thereof. The composition of the effluents from the barrier model were analysed either offline by electrospray-ionisation-mass spectrometry (ESI-MS), or online in the final compartment using chip-based ESI-MS. Two model drugs, omeprazole and verapamil, were used to test the integrated model. Omeprazole was shown to be broken down upon treatment with gastric acid, but reached the cell barrier unharmed when introduced to the system in a manner emulating an enteric-coated formulation. In contrast, verapamil was unaffected by digestion. Finally, a reduced uptake of verapamil was observed when verapamil was introduced to the system dissolved in apple juice, a simple food matrix. It is envisaged that this integrated, compartmentalised GI system has potential for enabling future research in the fields of pharmacology, toxicology, and nutrition.


Subject(s)
Gastrointestinal Tract/metabolism , Omeprazole/pharmacology , Verapamil/pharmacology , Biological Availability , Caco-2 Cells , Humans , Intestinal Absorption , Lab-On-A-Chip Devices
13.
Anal Chim Acta ; 1140: 190-198, 2020 Dec 15.
Article in English | MEDLINE | ID: mdl-33218481

ABSTRACT

While consumer-focused food analysis is upcoming, the need for multiple sample preparation and handling steps is limiting. On-site and consumer-friendly analysis paradoxically still requires laboratory-based and skill-intensive sample preparation methods. Here, we present a compact, inexpensive, and novel prototype immunosensor combining sample preparation and on-chip reagent storage for multiplex allergen lateral flow immunosensing. Our comprehensive approach paves the way for personalized consumer diagnostics. The prototype allows for handheld solid-liquid extraction, pipette-free on-chip dilution, and adjustment of sample concentrations into the appropriate assay dynamic working range. The disposable and interconnectable homogenizer unit allows for the extraction and 3D-sieve based filtration of allergenic proteins from solid bakery products in 1 min. The homogenizer interconnects with a 3D-printed unibody lab-on-a-chip (ULOC) microdevice, which is used to deliver precise volumes of sample extract to a reagent reservoir. The reagent reservoir is implemented for on-chip storage of carbon nanoparticle labeled antibodies and running buffer for dilution. The handheld prototype allows for total homogenization of solid samples, solid-liquid protein extraction, 3D-printed sieve based filtration, ULOC-enabled dilution, mixing, transport, and smartphone-based detection of hazelnut and peanut allergens in solid bakery products with limited operational complexity. The multiplex lateral flow immunoassay (LFIA) detects allergens as low as 0.1 ppm in real bakery products, and the system is already consumer-operable, demonstrating its potential for future citizen science approaches. The designed system is suitable for a wide range of analytical applications outside of food safety, provided an LFIA is available.


Subject(s)
Biosensing Techniques , Allergens , Immunoassay , Lab-On-A-Chip Devices , Smartphone
14.
Anal Chem ; 92(23): 15587-15595, 2020 12 01.
Article in English | MEDLINE | ID: mdl-33185097

ABSTRACT

Sandwich lateral flow immunoassays (LFIAs) are limited at high antigen concentrations by the hook effect, leading to a contradictory decrease in the test line (T) intensity and false-negative results. The hook effect is mainly associated with the loss of T, and research focuses on minimizing this effect. Nevertheless, the control line (C) intensity is also affected at higher analyte concentrations, undesirably influencing the T/C ratio in LFIA readers. The main aim of this work is to identify and understand these high antigen concentration effects in order to develop ubiquitous strategies to interpret and mitigate such effects. Four complementary experiments were performed: performance assessment of three different allergen LFIAs (two for hazelnut, one for peanut) over 0.075-3500 ppm, LFIAs with C only, surface plasmon resonance (SPR) binding experiments on the immobilized control antibody, and smartphone video recording of LFIAs during their development. As antigen concentrations increase, the C signal decreases before the T signal does, suggesting that distinct mechanisms underlie these intensity reductions. Reduced binding at the C occurred even in the absence of T, so the upfront T does not explain the loss of C. SPR confirmed that the C antibody favors binding with free labeled antibody compared with a labeled antibody-analyte complex, indicating that in antigen excess, binding is reduced at C before T. Finally, a smartphone-based video method was developed for dynamically monitoring the LFIA development in real time to distinguish between different concentration-dependent effects. Digitally analyzing the data allows clear differentiation of highly positive samples and false-negative samples and can indicate whether the LFIA is in the dynamic working range or at critically high concentrations. The aim of this work is to identify and understand such high antigen concentration effects in order to develop ubiquitous strategies to interpret and mitigate such effects.


Subject(s)
Allergens/analysis , Immunoassay/methods , Allergens/immunology , Antibodies, Immobilized/chemistry , Antibodies, Immobilized/immunology , Arachis/immunology , Corylus/immunology , Immunoassay/instrumentation , Limit of Detection , Smartphone , Surface Properties
15.
J Am Soc Mass Spectrom ; 31(11): 2243-2249, 2020 Nov 04.
Article in English | MEDLINE | ID: mdl-33086002

ABSTRACT

On-site testing in food analysis using mass spectrometry (MS) requires miniaturization of vacuum systems, mass analyzers, sample cleanup, and ionization sources. In this study, a simple coated blade spray (CBS) ion source was developed that enables high voltage generation on the blade by ubiquitous certified (micro-)USB On-The-Go devices like smartphones, tablets, and power banks. CBS is capable of performing both analyte enrichment by solid-phase microextraction (SPME) material coated on the metal substrate and direct-spray ionization. The USB-CBS device was used on two different MS systems, a transportable single-quadrupole and a benchtop triple-quadrupole tandem MS. Various characteristics of the USB-CBS device, including high voltage generation and angular positioning, were studied. The potential of the newly developed device for food safety applications is demonstrated by banned and regulated veterinary drugs such as ß-agonists and sulfonamide antibiotics, covering a wide range of molecular weights and polarities. The results highlight the potential of the developed, simplified, inexpensive (less than 10 USD), and universal vendor-independent USB-powered CBS ion source coupled with MS(/MS) systems for semiquantitative applications, in laboratories, and in future on-site food quality and safety testing. Apart from that, most likely on-site environmental, biomedical, and forensic testing will also benefit from this USB-CBS instrumental development that is compatible with any atmospheric inlet MS system.

16.
Anal Bioanal Chem ; 412(27): 7547-7558, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32860092

ABSTRACT

Lateral flow immunoassays (LFIAs) are widely used for rapid food safety screening analysis. Thanks to simplified protocols and smartphone readouts, LFIAs are expected to be increasingly used on-site, even by non-experts. As a typical follow-up in EU regulatory settings, suspect samples are sent to laboratories for confirmatory analysis by liquid chromatography-tandem mass spectrometry (LC-MS/MS). However, re-analysis by LC-MS/MS is laborious and time-consuming. In this work, an identification LFIA (ID-LFIA) approach followed by quadrupole-orbitrap MS or triple quadrupole MS/MS analysis is presented. As a proof of concept, a dedicated ID-LFIA strip was developed for the mycotoxin deoxynivalenol (DON) following its initial screening by a commercial smartphone LFIA. The ID-LFIA strip can be simply immersed in the same sample extract used for the smartphone LFIA screening, and next, DON is retrieved from the monoclonal antibody with a dissociation solution consisting of methanol/ammonia. The solution thus obtained was analyzed directly in MS in order to rapidly confirm the presence of DON and any cross-reacting species. The protocol developed is capable of coping with severe ion suppression caused by LFIA buffers and nitrocellulose substrate residues. Initial analysis of blank, spiked, and incurred samples showed that the newly developed ID-LFIA-MS method was able to confirm the presence or absence of mycotoxins in the samples previously analyzed by LFIA and also differentiate between DON and DON 3-glucoside yielding the positive screening result. The concept and technique developed are envisaged to complement on-site screening and confirmation of any low molecular weight contaminant in future food control frameworks. Graphical abstract.


Subject(s)
Food Analysis/methods , Food Contamination/analysis , Spectrometry, Mass, Electrospray Ionization/methods , Trichothecenes/analysis , Beer/analysis , Collodion/chemistry , Equipment Design , Food Analysis/instrumentation , Hordeum/chemistry , Immunoassay/instrumentation , Immunoassay/methods , Spectrometry, Mass, Electrospray Ionization/instrumentation , Triticum/chemistry
17.
J Am Soc Mass Spectrom ; 31(2): 249-256, 2020 Feb 05.
Article in English | MEDLINE | ID: mdl-32031404

ABSTRACT

Identification and confirmation of known as well as unknown (bio)chemical entities in ambient mass spectrometry (MS) and MS imaging (MSI) mostly involve accurate mass determination, often in combination with MS/MS or MSn work flows. To further improve structural assignment, additional molecular information is required. Here we present an ambient hydrogen/deuterium exchange (HDX) laser ablation electrospray ionization (LAESI) MS method in which, apart from the accurate mass and MS/MS data, the number of exchangeable protons in (un)known molecules is obtained. While eventually presenting ambient HDX-LAESI-MSI, samples were not preincubated with deuterated solvents, but instead HDX occurred following fusion of ablated sample material with microdroplets generated by ESI of deuterated solvents. Therefore, the degree of HDX was first studied following ablation of nondeuterated sample solutions of melamine and monosaccharides. From these experiments, it was concluded that the set-up used could provide meaningful HDX data in support of molecular structure elucidation by significantly reducing the number of structure options from a measured elemental composition. This reduction was demonstrated with an unknown accurate m/z value obtained in the analysis of an orange slice, reducing the possible number of molecular structures having the same elemental composition by 87% due to the number of H/D exchanges observed. Next, deuterated and nondeuterated MS/MS experiments showed the number of exchangeable protons in the substructures from deuterated neutral losses in the product ion spectra, confirming the compound to be arginine. Finally, the potential of ambient HDX-LAESI-MSI was demonstrated by the imaging of (secondary) plant metabolites in a Phalaenopsis petal.


Subject(s)
Deuterium Exchange Measurement/methods , Monosaccharides/chemistry , Spectrometry, Mass, Electrospray Ionization/methods , Triazines/chemistry , Hydrogen/chemistry , Laser Therapy , Protons , Tandem Mass Spectrometry/methods
18.
Anal Bioanal Chem ; 412(5): 1111-1122, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31865418

ABSTRACT

In oral bioavailability studies, evaluation of the absorption and transport of drugs and food components across the intestinal barrier is crucial. Advances in the field of organ-on-a-chip technology have resulted in a dynamic gut-on-a-chip model that better mimics the in vivo microenvironment of the intestine. Despite a few recent integration attempts, ensuring a biologically relevant microenvironment while coupling with a fully online detection system still represents a major challenge. Herein, we designed an online technique to measure drug permeability and analyse unknown product formation across an intestinal epithelial layer of Caco-2 and HT29-MTX cells cultured on a flow-through Transwell system, while ensuring the quality and relevance of the biological model. Chip-based ultra-performance liquid chromatography quadrupole time-of-flight mass spectrometry (UPLC-QTOF-MS) was coupled to the dynamic Transwell system via a series of switching valves, thus allowing alternating measurements of the apical and basolateral sides of the in vitro model. Two trap columns were integrated for online sample pre-treatment and compatibility enhancement. Temporal analysis of the intestinal permeability was successfully demonstrated using verapamil as a model drug and ergotamine epimers as a model for natural toxins present in foods. Evidence was obtained that our newly developed dynamic system provided reliable results versus classical static in vitro models, and moreover, for the first time, epimer-specific transport is shown for ergotamine. Finally, initial experiments with the drug granisetron suggest that metabolic activity can be studied as well, thus highlighting the versatility of the bio-integrated online analysis system developed. Graphical abstract.


Subject(s)
Chromatography, Liquid/methods , Intestinal Mucosa/metabolism , Lab-On-A-Chip Devices , Models, Biological , Spectrometry, Mass, Electrospray Ionization/methods , Tandem Mass Spectrometry/methods , Administration, Oral , Biological Availability , Biotransformation , Caco-2 Cells , Ergotamine/administration & dosage , Ergotamine/pharmacokinetics , Granisetron/administration & dosage , Granisetron/pharmacokinetics , HT29 Cells , Humans , In Vitro Techniques , Limit of Detection , Permeability , Verapamil/administration & dosage , Verapamil/pharmacokinetics
19.
Biosensors (Basel) ; 9(4)2019 Dec 12.
Article in English | MEDLINE | ID: mdl-31842439

ABSTRACT

(1) Background: The lack of globally standardized allergen labeling legislation necessitates consumer-focused multiplexed testing devices. These should be easy to operate, fast, sensitive and robust. (2) Methods: Herein, we describe the development of three different formats for multiplexed food allergen detection, namely active and passive flow-through assays, and lateral flow immunoassays with different test line configurations. (3) Results: The fastest assay time was 1 min, whereas even the slowest assay was within 10 min. With the passive flow approach, the limits of detection (LOD) of 0.1 and 0.5 ppm for total hazelnut protein (THP) and total peanut protein (TPP) in spiked buffer were reached, or 1 and 5 ppm of THP and TPP spiked into matrix. In comparison, the active flow approach reached LODs of 0.05 ppm for both analytes in buffer and 0.5 and 1 ppm of THP and TPP spiked into matrix. The optimized LFIA configuration reached LODs of 0.1 and 0.5 ppm of THP and TPP spiked into buffer or 0.5 ppm for both analytes spiked into matrix. The optimized LFIA was validated by testing in 20 different blank and spiked matrices. Using device-independent color space for smartphone analysis, two different smartphone models were used for the analysis of optimized assays.


Subject(s)
Allergens/analysis , Biosensing Techniques , Food Hypersensitivity/diagnosis , Immunoassay , Smartphone , Food Hypersensitivity/immunology , Humans
20.
Rapid Commun Mass Spectrom ; 33(20): 1578-1588, 2019 Oct 30.
Article in English | MEDLINE | ID: mdl-31240795

ABSTRACT

RATIONALE: Retroactive analysis of previously tested urine samples has become an important sports anti-doping tool. Retroactive reprocessing of old data files acquired from a generic screening procedure can reveal detection of initially unknown substances, like illegal drugs and newly identified metabolites. METHODS: To be able to efficiently search through hundreds to thousands of liquid chromatography high-resolution full-scan Orbitrap mass spectrometry data files of anti-doping samples, a combination of MetAlign and HR_MS_Search software has been developed. MetAlign reduced the data size ca 100-fold making possible local storage of a massive volume of data. RESULTS: The newly developed HR_MS_Search module can search through the reduced data files for new compounds (mass or isotope pattern) defined by mass windows and retention time windows. A search for 33 analytes in 940 reduced data files lasted 10 s. The output of the automatic search was compared to the standard manual routine evaluation. The results of searching were evaluated in terms of false negatives and false positives. The newly banned b2-agonist higenamine and its metabolite coclaurine were successfully searched in reduced data files originating from a testing period for which these substances were not banned, as an example of retroactive analysis. CONCLUSIONS: The freeware MetAlign software and its automatic searching module HR_MS_Search facilitated the retroactive reprocessing of reduced full-scan high-resolution liquid chromatography/mass spectrometry screening data files and created a new tool in anti-doping laboratories' network.


Subject(s)
Adrenergic beta-Agonists/urine , Alkaloids/urine , Chromatography, Liquid/methods , Mass Spectrometry/methods , Tetrahydroisoquinolines/urine , Adrenergic beta-Agonists/metabolism , Alkaloids/metabolism , Doping in Sports/prevention & control , Humans , Isoquinolines/urine , Substance Abuse Detection , Tetrahydroisoquinolines/metabolism , Urinalysis
SELECTION OF CITATIONS
SEARCH DETAIL
...