Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Analyst ; 127(8): 1045-9, 2002 Aug.
Article in English | MEDLINE | ID: mdl-12195944

ABSTRACT

A method was developed for the simultaneous determination of the following nine volatile sulfur compounds in gas samples: carbon disulfide, carbonyl sulfide, ethyl sulfide, ethyl methyl sulfide, hydrogen sulfide, isopropanethiol, methanethiol, methyl disulfide and methyl sulfide. The target compounds were preconcentrated by solid-phase microextraction (SPME) and determined by gas chromatography combined with mass spectrometry. Experimental design was employed to optimize the extraction time and temperature and concurrent detection of the nine compounds was achieved by using an SPME fiber coated with Carboxen-polydimethylsiloxane (75 microns). Detection limits ranged from 1 ppt (v/v) for carbon disulfide to 350 ppt (v/v) for hydrogen sulfide and calibration functions were linear up to 20 ppb (v/v) for all the compounds investigated.


Subject(s)
Sulfur Compounds/analysis , Water Pollutants, Chemical/analysis , Gas Chromatography-Mass Spectrometry/methods
2.
J Chromatogr A ; 963(1-2): 57-64, 2002 Jul 19.
Article in English | MEDLINE | ID: mdl-12188001

ABSTRACT

Procedures were assessed for quantifying nine volatile sulfur compounds found in complex gaseous samples collected at a biogas-production plant and a sewage treatment plant. The target compounds were extracted by solid-phase microextraction (using the 75-microm Carboxen-polydimethylsiloxane fiber coating) at 22 degrees C for 20 min, and analyzed by GC-MS. Detection limits ranged between 1 pptv (v/v) for carbon disulfide and 470 pptv (v/v) for hydrogen sulfide. High amounts of organic compounds were found during full-scan analysis of the samples and standard additions to individual sub-samples revealed that the analysis was subject to matrix effects. However, the functions obtained by standard additions were still linear and quantification was possible for all the compounds tested except hydrogen sulfide. No detectable losses were observed during storage in the sampling containers, made of Tedlar film, over a storage period of 20 h. However, water permeated through the walls and the relative humidity in the bag increased during storage until it reached the ambient level. Finally, it was shown that the drying agent, CaCl2, caused no detectable losses of any of the compounds.


Subject(s)
Gases/chemistry , Sulfur Compounds/analysis , Gas Chromatography-Mass Spectrometry/methods , Sensitivity and Specificity , Volatilization
SELECTION OF CITATIONS
SEARCH DETAIL
...