1.
J Water Health ; 14(1): 121-31, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26837836

ABSTRACT

The purpose of this equivalence study was to compare an alternative method, Colilert-18 Quanti-Tray (ISO 9308-2) with the European bathing water directive (2006/7/EC) reference method, the miniaturised most probable number (MMPN) method (ISO 9308-3), for the analysis of Escherichia coli. Six laboratories analysed a total of 263 bathing water samples in Finland. The comparison was carried out according to ISO 17994:2004. The recovery of E. coli using the Colilert-18 method was 7.0% and 8.6% lower than that of the MMPN method after 48 hours and 72 hours of incubation, respectively. The confirmation rate of presumptive E. coli-positive wells in the Colilert-18 and MMPN methods was high (97.8% and 98.0%, respectively). However, the testing of presumptive E. coli-negative but coliform bacteria-positive (yellow but not fluorescent) Colilert-18 wells revealed 7.3% false negative results. There were more false negatives in the naturally contaminated waters than in the samples spiked with waste water. The difference between the recovery of Colilert-18 and the MMPN method was considered not significant, and subsequently the methods are considered as equivalent for bathing water quality monitoring in Finland. Future bathing water method equivalence verification studies may use the data reported herein. The laboratories should make sure that any wells showing even minor fluorescence will be determined as positive for E. coli.


Subject(s)
Baths , Environmental Monitoring/methods , Escherichia coli/isolation & purification , Water Microbiology , Water Quality , Colony Count, Microbial
2.
Water Res ; 36(10): 2627-35, 2002 May.
Article in English | MEDLINE | ID: mdl-12153030

ABSTRACT

The aim of this study was to investigate endotoxin concentrations in cyanobacterial water blooms and strains, and to assess the removal of endotoxins during drinking water treatment. Endotoxin concentrations were measured from 151 hepatotoxic, neurotoxic and non-toxic cyanobacterial water blooms by using Limulus amebocyte lysate (LAL) assay, and the results were compared to bacterial data. Endotoxin activities ranged from 20 to 3.8 x 10(4) endotoxin units (EU) per ml. Endotoxicity of the samples correlated with phycobiliprotein concentration that was used to assess cyanobacterial abundance, heterotrophic plate count, and Aeromonas spp. but it did not correlate with the number of coliforms or streptococci. The high endotoxin concentrations occasionally detected in the water bloom samples were probably due to Gram negative bacteria that existed together with cyanobacteria since the 26 axenic cyanobacterial strains from different genera that were studied showed very low endotoxin activity. No differences in endotoxin activity were detected between hepatotoxic, neurotoxic and non-toxic strains. Removal of endotoxins during drinking water treatment was studied at nine waterworks that previously had been associated with high numbers of cyanobacteria and that used different processes for water purification. Endotoxin concentration in raw waters ranged from 18 to 356 EU ml(-1). The treatment processes reduced 59-97% of the endotoxin activity; in the treated water the concentration ranged from 3 to 15 EU ml(-1). The most significant reduction occurred at the early stages of water treatment, during coagulation, settling and sand filtration. Activated carbon filtration either increased or had no effect on endotoxin concentration. Ozonation and chlorination had little effect on the endotoxin concentrations.


Subject(s)
Cyanobacteria , Endotoxins/analysis , Endotoxins/isolation & purification , Eutrophication , Water Purification , Water Supply , Environmental Monitoring , Filtration , Silicon Dioxide