Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
J Cardiovasc Comput Tomogr ; 13(2): 92-98, 2019.
Article in English | MEDLINE | ID: mdl-30665879

ABSTRACT

BACKGROUND: To investigate whether aortic valve calcification (AVC) scoring performed with different workstation platforms generates comparable and thus software-independent results. METHODS: In this IRB-approved retrospective study, we included 100 consecutive patients with symptomatic aortic stenosis undergoing CT prior to transcatheter aortic valve implantation. Two independent observers performed AVC scoring on non-enhanced images with commercially available software platforms of four vendors (GE, Philips, Siemens, 3mensio). Gender-specific Agatston score cut-off values were applied according to current recommendations to assign patients to different likelihood categories of aortic stenosis (unlikely to very likely). Comparative analysis of Agatston scores between the four platforms were performed by using Kruskal-Wallis analysis, Spearman rank correlation, linear regression analysis, and Bland-Altman analysis. Differences in category assignment were compared using Fisher's exact test and Cohen's kappa. RESULTS: For both observers, each workstation platform produced slightly different numeric AVC Agatston scores, however, without statistical significance (p = 0.96 and p = 0.98). Excellent correlation was found between platforms, with r = 0.991-0.996 (Spearman) and r2 = 0.981-0.992 (regression analysis) for both observers. Bland-Altman analyses revealed small mean differences with narrow limits of agreement between platforms (mean differences: 6 ±â€¯128 to 100 ±â€¯179), for inter-observer (mean differences: 1 ±â€¯43 to 12 ±â€¯70), and intra-observer variability (mean differences: 9 ±â€¯42 to 20 ±â€¯96). Observer 1 assigned 11 (kappa: 0.85-0.97) and observer 2 assigned 10 patients (kappa: 0.88-0.95) to different likelihood groups of severe aortic stenosis with at least one platform. Overall, there was no significant difference of likelihood assignment between platforms (p = 0.98 and p = 1.0, respectively). CONCLUSION: While absolute values differ slightly, common commercially available software platforms produce comparable results for AVC scoring, which indicates software-independence of the method.


Subject(s)
Aortic Valve Stenosis/diagnostic imaging , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Calcinosis/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Software , Tomography, X-Ray Computed , Aged , Aged, 80 and over , Female , Humans , Male , Observer Variation , Predictive Value of Tests , Reproducibility of Results , Retrospective Studies , Severity of Illness Index
2.
J Am Coll Cardiol ; 66(19): 2075-2088, 2015.
Article in English | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1063629

ABSTRACT

BACKGROUND:Cardiac biomarker release signifying myocardial injury post-transcatheter aortic valve replacement (TAVR) is common, yet its clinical impact within a large TAVR cohort receiving differing types of valve and procedural approaches is unknown.OBJECTIVES:This study sought to determine the incidence, clinical impact, and factors associated with cardiac biomarker elevation post TAVR.METHODS:This multicenter study included 1,131 consecutive patients undergoing TAVR with balloon-expandable (58%) or self-expandable (42%) valves. Transfemoral and transapical (TA) approaches were selected in 73.1% and 20.3% of patients, respectively. Creatine kinase-myocardial band (CK-MB) measurements were obtained at baseline and at several time points within the initial 72 h post TAVR. Echocardiography was performed at baseline and at 6- to 12-month follow-up.RESULTS:Overall, 66% of the TAVR population demonstrated some degree of myocardial injury as determined by a rise in CK-MB levels (peak value: 1.6-fold [interquartile range (IQR): 0.9 to 2.8-fold]). A TA approach and major procedural complications were independently associated with higher peak of CK-MB levels (p < 0.01 for all), which translated into impaired systolic left ventricular function at 6 to 12 months post TAVR (p < 0.01). A greater rise in CK-MB levels independently associated with an increased 30-day, late (median of 21 [IQR: 8 to 36] months) overall and cardiovascular mortality (p < 0.001 for all)...


Subject(s)
Biomarkers , Creatine Kinase , Carotid Stenosis , Transcatheter Aortic Valve Replacement
3.
Neth Heart J ; 22(3): 115-21, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24338787

ABSTRACT

AIMS: Heart failure (HF) management is complicated by difficulties in clinical assessment. Biomarkers may help guide HF management, but the correspondence between clinical evaluation and biomarker serum levels has hardly been studied. We investigated the correlation between biomarkers and clinical signs and symptoms, the influence of patient characteristics and comorbidities on New York Heart Association (NYHA) classification and the effect of using biomarkers on clinical evaluation. METHODS AND RESULTS: This post-hoc analysis comprised 622 patients (77 ± 8 years, 76 % NYHA class ≥3, 80 % LVEF ≤45 %) participating in TIME-CHF, randomising patients to either NT-proBNP-guided or symptom-guided therapy. Biomarker measurements and clinical evaluation were performed at baseline and after 1, 3, 6, 12 and 18 months. NT-proBNP, GDF-15, hs-TnT and to a lesser extent hs-CRP and cystatin-C were weakly correlated to NYHA, oedema, jugular vein distension and orthopnoea (ρ-range: 0.12-0.33; p < 0.01). NT-proBNP correlated more strongly to NYHA class in the NT-proBNP-guided group compared with the symptom-guided group. NYHA class was significantly influenced by age, body mass index, anaemia, and the presence of two or more comorbidities. CONCLUSION: In HF, biomarkers correlate only weakly with clinical signs and symptoms. NYHA classification is influenced by several comorbidities and patient characteristics. Clinical judgement seems to be influenced by a clinician's awareness of NT-proBNP concentrations.

4.
Anaesthesist ; 60(12): 1095-108, 2011 Dec.
Article in German | MEDLINE | ID: mdl-22179072

ABSTRACT

Surgical replacement of aortic valves is the gold standard for therapy of high grade aortic valve stenosis. However, the changes in demography confront the responsible medical discipline with an increasingly higher risk profile of patients which necessitates the development of new less invasive alternative forms of treatment for the surgical therapy of aortic valve stenosis. This developmental process has progressed from mini-thoracotomy to transcatheter aortic valve implantation (TAVI). The TAVI procedure is a new therapeutic option for treatment of patients with high grade aortic valve stenosis and high perioperative morbidity and mortality risks with conventional aortic valve replacement. Because TAVI can be carried out while the heart is still beating and without a sternotomy or heart-lung maschine, this procedure is particularly suitable for elderly multimorbid patients and/or patients with previous cardiac surgery. The initial results of large prospective multicenter studies underline the value of TAVI in the modern treatment of high risk patients with symptomatic aortic valve stenosis. In addition to an understanding of the surgical procedure, anesthetists must have precise knowledge of the perioperative anesthesia management and possible complications of the procedure.


Subject(s)
Anesthesia , Aortic Valve/surgery , Cardiac Catheterization , Catheterization/methods , Heart Valve Prosthesis Implantation/methods , Anticoagulants/therapeutic use , Aortic Valve Stenosis/surgery , Echocardiography, Transesophageal , Heart Valve Prosthesis , Hemodynamics/physiology , Humans , Monitoring, Intraoperative , Multicenter Studies as Topic , Postoperative Complications/prevention & control , Postoperative Complications/therapy , Prospective Studies , Prosthesis Design , Risk Assessment , Thoracotomy
5.
Circulation ; 122(13): 1319-27, 2010 Sep 28.
Article in English | MEDLINE | ID: mdl-20837893

ABSTRACT

BACKGROUND: Although short- and medium-term outcomes after transcatheter aortic valve implantation are encouraging, long-term data on valve function and clinical outcomes are limited. METHODS AND RESULTS: Consecutive high-risk patients who had been declined as surgical candidates because of comorbidities but who underwent successful transcatheter aortic valve implantation with a balloon-expandable valve between January 2005 and December 2006 and survived past 30 days were assessed. Clinical, echocardiographic, and computed tomographic follow-up examinations were performed. Seventy patients who underwent successful procedures and survived longer than 30 days were evaluated at a minimum follow-up of 3 years. At a median follow-up of 3.7 years (interquartile range 3.4 to 4.3 years), survival was 57%. Survival at 1, 2, and 3 years was 81%, 74%, and 61%, respectively. Freedom from reoperation was 98.5% (1 patient with endocarditis). During this early procedural experience, 11 patients died within 30 days, and 8 procedures were unsuccessful. When these patients were included, overall survival was 51%. Transaortic pressure gradients increased from 10.0 mm Hg (interquartile range 8.0 to 12.0 mm Hg) immediately after the procedure to 12.1 mm Hg (interquartile range 8.6 to 16.0 mm Hg) after 3 years (P=0.03). Bioprosthetic valve area decreased from a mean of 1.7±0.4 cm(2) after the procedure to 1.4±0.3 cm(2) after 3 years (P<0.01). Aortic incompetence after implantation was trivial or mild in 84% of cases and remained unchanged or improved over time. There were no cases of structural valvular deterioration, stent fracture, deformation, or valve migration. CONCLUSIONS: Transcatheter aortic valve implantation demonstrates good medium- to long-term durability and preserved hemodynamic function, with no evidence of structural failure. The procedure appears to offer an adequate and lasting resolution of aortic stenosis in selected patients.


Subject(s)
Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation , Hemodynamics , Aged, 80 and over , Aortic Valve Stenosis/mortality , Cohort Studies , Follow-Up Studies , Heart Valve Prosthesis Implantation/adverse effects , Humans , Survival Rate , Time Factors , Tomography, X-Ray Computed , Treatment Outcome
6.
Clin Pharmacol Ther ; 87(6): 686-92, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20445533

ABSTRACT

Inhibition of the renin-angiotensin system (RAS) improves hemodynamics and may ameliorate oxidative stress in heart failure (HF). Through activation of nicotinamide adenine dinucleotide phosphate oxidase, angiotensin II induces superoxide, which is primarily cleared by cytosolic copper-zinc superoxide dismutase (Cu/Zn-SOD). We examined the interdependency of hemodynamics and levels of Cu/Zn-SOD and oxidized low-density lipoprotein (oxLDL) in HF patients, using a randomized, double-blinded, crossover design to compare (i) the outcomes of single-agent therapy with either benazepril or valsartan alone vs. the combination thereof and (ii) the outcome of single-agent treatment with benazepril vs. single-agent treatment with valsartan. After each treatment, arterial (ART) and coronary sinus (CS) blood samples were collected. Cu/Zn-SOD and oxLDL levels were higher in CS samples than in ART samples. Furthermore, patients under combined treatment exhibited the highest CS levels of Cu/Zn-SOD, whereas there was no significant difference between the groups on either benazepril or valsartan alone. This finding suggests an augmentation of the cardiac antioxidative potential under more complete RAS inhibition. Cu/Zn-SOD and oxLDL levels correlated with measures of afterload rather than preload, which in turn suggests a beneficial effect of afterload reduction on oxidative stress in HF.


Subject(s)
Benzazepines/pharmacology , Heart Failure/drug therapy , Renin-Angiotensin System/drug effects , Superoxide Dismutase/drug effects , Tetrazoles/pharmacology , Valine/analogs & derivatives , Adult , Aged , Angiotensin II Type 1 Receptor Blockers/administration & dosage , Angiotensin II Type 1 Receptor Blockers/pharmacology , Angiotensin-Converting Enzyme Inhibitors/administration & dosage , Angiotensin-Converting Enzyme Inhibitors/pharmacology , Benzazepines/administration & dosage , Cross-Over Studies , Double-Blind Method , Drug Therapy, Combination , Female , Heart Failure/physiopathology , Hemodynamics/drug effects , Humans , Lipoproteins, LDL/drug effects , Lipoproteins, LDL/metabolism , Male , Middle Aged , Oxidative Stress/drug effects , Superoxide Dismutase/metabolism , Tetrazoles/administration & dosage , Valine/administration & dosage , Valine/pharmacology , Valsartan
SELECTION OF CITATIONS