Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Prev Cardiol ; 30(5): 384-392, 2023 03 27.
Article in English | MEDLINE | ID: mdl-36562212

ABSTRACT

AIMS: Coronary atheroma volume is associated with risk of coronary events in coronary artery disease (CAD). Exercise training is a cornerstone in primary and secondary prevention of CAD, but the effect of exercise on coronary atheromatous plaques is largely unknown. We assessed the effect of 6 months supervised high-intensity interval training (HIIT) on coronary plaque geometry using intravascular ultrasound in patients with stable CAD following percutaneous coronary intervention (PCI). METHODS AND RESULTS: Sixty patients were randomized to two sessions of weekly supervised HIIT at 85-95% of peak heart rate (n = 30) or to follow contemporary preventive guidelines (control group, n = 30). The study endpoints were change in percent atheroma volume (PAV) and total atheroma volume (TAV) normalized for segment length (TAVnorm) at 6-month follow-up. The change in average PAV for matched coronary segments from baseline to follow-up showed a significant between-group difference (-1.4, 95% CI: -2.7 to -0.1, P = 0.036). There was a significant reduction in the HIIT group (-1.2, 95% CI: -2.1 to -0.2, P = 0.017) while not in the control group (0.2, 95% CI: -0.7 to 1.1, P = 0.616). TAVnorm was reduced (-9 mm3, 95% CI: -14.7 to -3.4, P = 0.002) after HIIT, with a significant between-group difference (-12.0 mm3, 95% CI: -19.9 to -4.2, P = 0.003). CONCLUSION: In patients with established CAD, a regression of atheroma volume was observed in those undergoing 6 months of supervised HIIT compared with patients following contemporary preventive guidelines. Our study indicates that HIIT counteracts atherosclerotic coronary disease progression and reduces atheroma volume in residual coronary atheromatous plaques following PCI.


Subject(s)
Coronary Artery Disease , High-Intensity Interval Training , Percutaneous Coronary Intervention , Plaque, Atherosclerotic , Humans , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Percutaneous Coronary Intervention/adverse effects , Disease Progression , Ultrasonography, Interventional/methods
2.
Sci Rep ; 12(1): 8239, 2022 05 17.
Article in English | MEDLINE | ID: mdl-35581305

ABSTRACT

This study evaluated acute cardiac stress after a high-intensity interval training session in patients with type 2 diabetes (T2D) versus healthy controls. High intensity aerobic exercise was performed by 4 × 4-min intervals (90-95% of maximal heart rate), followed by a ramp protocol to peak oxygen uptake. Echocardiography was performed before and 30 min after exercise. Holter electrocardiography monitored heart rhythms 24 h before, during, and 24 h after the exercise. Left atrial end-systolic volume, peak early diastolic mitral annular velocity, and the ratio of peak early to late diastolic mitral inflow velocity were reduced by approximately 18%, 15%, and 31%, respectively, after exercise across groups. Left ventricular end-diastolic wall thickness was the only echo parameter that significantly differed between groups in response to exercise. The T2D group had a rate of supraventricular extrasystoles per hour that was 265% greater than that of the controls before exercise, which remained higher after exercise. A single exhaustive exercise session impaired left ventricular diastolic function in both groups. The findings also indicated impaired right ventricular function in patients with T2D after exercise.ClinicalTrials.gov Identifier: NCT02998008.


Subject(s)
Diabetes Mellitus, Type 2 , Diastole/physiology , Exercise Test , Humans , Pilot Projects , Ventricular Function, Left/physiology
3.
J Am Heart Assoc ; 11(10): e024705, 2022 05 17.
Article in English | MEDLINE | ID: mdl-35574968

ABSTRACT

Background The effect of physical exercise on lipid content of coronary artery plaques is unknown. With near infrared spectroscopy we measured the effect of high intensity interval training (HIIT) on lipid content in coronary plaques in patients with stable coronary artery disease following percutaneous coronary intervention. Methods and Results In CENIT (Impact of Cardiac Exercise Training on Lipid Content in Coronary Atheromatous Plaques Evaluated by Near-Infrared Spectroscopy) 60 patients were randomized to 6 months supervised HIIT or to a control group. The primary end point was change in lipid content measured as maximum lipid core burden index at 4 mm (maxLCBI4mm). A predefined cutoff of maxLCBI4mm >100 was required for inclusion in the analysis. Forty-nine patients (HIIT=20, usual care=29) had maxLCBI4mm >100 at baseline. Change in maxLCBI4mm did not differ between groups (-1.2, 95% CI, -65.8 to 63.4, P=0.97). The estimated reduction in maxLCBI4mm was -47.7 (95% CI, -100.3 to 5.0, P=0.075) and -46.5 (95% CI, -87.5 to -5.4, P=0.027) after HIIT and in controls, respectively. A negative correlation was observed between change in peak oxygen uptake (VO2peak) and change in lipid content (Spearman's correlation -0.44, P=0.009). With an increase in VO2peak above 1 metabolic equivalent task, maxLCBI4mm was on average reduced by 142 (-8 to -262), whereas the change was -3.2 (154 to -255) with increased VO2peak below 1 metabolic equivalent task. Conclusions Six months of HIIT following percutaneous coronary intervention did not reduce lipid content in coronary plaques compared with usual care. A moderate negative correlation between increase in VO2peak and change in lipid content generates the hypothesis that exercise with a subsequent increase in fitness may reduce lipid content in coronary atheromatous plaques. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT02494947.


Subject(s)
Coronary Artery Disease , Plaque, Atherosclerotic , Coronary Artery Disease/metabolism , Coronary Artery Disease/therapy , Exercise , Humans , Lipids , Spectroscopy, Near-Infrared
4.
J Ultrasound Med ; 40(2): 341-350, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32710577

ABSTRACT

OBJECTIVES: Handheld ultrasound devices (HUDs) have previously been limited to grayscale imaging without options for left ventricle (LV) quantification. We aimed to study the feasibility and reliability of automatic measurements of mitral annular plane systolic excursion (MAPSE) by HUDs. METHODS: An algorithm that automatically measured MAPSE from live grayscale recordings was implemented in a HUD. Twenty patients at a university hospital were examined by either a cardiologist or a sonographer. Standard echocardiography using a high-end scanner was performed. The apical 4-chamber view was recorded 4 times by both echocardiography and the HUD. MAPSE was measured by M-mode and color tissue Doppler (cTD) during echocardiography and automatically by the HUD. RESULTS: The automatic method underestimated mean MAPSE ± SD versus M-mode (9.6 ± 2.2 versus 10.9 ± 2.6 mm; difference, 1.2 ± 1.4 mm, P < .005). The difference between the automatic and cTD measurements was not significant (0.8 ± 1.8 mm; P = .073). The intraclass correlation coefficients (ICCs) between automatic and M-mode measurements was 0.85, and 0.81 for cTD measurements. There was good agreement between the methods, and the intra- and inter-rater ICCs were excellent for all methods (≥0.86). CONCLUSIONS: In this novel study evaluating automatic quantification of LV longitudinal function by HUD, we showed the high feasibility and reliability of the method. Compared to M-mode imaging, the automatic method underestimated MAPSE by 8% to 10%, but the difference with cTD imaging was nonsignificant. We conclude that this study's method for automatic quantitative assessment of LV function can be integrated in HUDs.


Subject(s)
Ventricular Dysfunction, Left , Feasibility Studies , Humans , Mitral Valve/diagnostic imaging , Pilot Projects , Reproducibility of Results , Systole
SELECTION OF CITATIONS
SEARCH DETAIL
...