Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Pharmacotherapy ; 44(3): 249-257, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38131129

ABSTRACT

STUDY OBJECTIVE: Studies have demonstrated sodium-glucose cotransporter-2 (SGLT2) inhibitors are kidney protective; however, their ability to cause hemodynamic changes may predispose patients to acute kidney injury (AKI). An FDA warning recommends evaluating for factors that predispose patients to AKI before initiating a SGLT2 inhibitor. The primary objective of this study is to identify risk factors that may predispose persons with diabetes to AKI when initiating SGLT2 inhibitor therapy. DESIGN: Multicenter retrospective cohort chart review. DATA SOURCE: Study patients were identified through an electronic medical record generated report if they had type 2 diabetes and were prescribed a SGLT2 inhibitor from January 2013 to September 2019. PATIENTS: Patients were included if they were receiving care at Advocate Medical Group and were confirmed to have taken one of the four SGLT2 inhibitors available at the time of study approval, canagliflozin, dapagliflozin, empagliflozin, or ertugliflozin, for at least 7 days. Patients were excluded if they did not have a basic metabolic panel or comprehensive metabolic panel recorded 1 year prior to or 6 months after SGLT2 inhibitor therapy initiation. RESULTS: Data extraction from the electronic medical record identified 6425 patients receiving a SGLT2 inhibitor, of which 1962 met inclusion criteria and were included for analysis. Thirty-five (1.8%) patients experienced an AKI after SGLT2 inhibitor therapy initiation. There was no statistically significant difference between groups based on background medication use (p = 0.325). At baseline, patients experiencing an AKI after SGLT2 inhibitor initiation were more likely to be older in age (p = 0.010), have a higher serum potassium (p < 0.001), blood glucose (p = 0.018), SCr (p = 0.009) and UACR (p < 0.001), and a lower eGFR (p = 0.028) compared to those who did not experience AKI. CONCLUSIONS: The transient eGFR decline with SGLT2 inhibitor initiation should be expected and is generally not an indication to discontinue therapy. Future initiatives should be directed at increasing knowledge of monitoring recommendations for these agents.


Subject(s)
Acute Kidney Injury , Diabetes Mellitus, Type 2 , Sodium-Glucose Transporter 2 Inhibitors , Humans , Sodium-Glucose Transporter 2 Inhibitors/adverse effects , Retrospective Studies , Acute Kidney Injury/chemically induced , Acute Kidney Injury/epidemiology , Risk Factors , Blood Glucose , Sodium , Hypoglycemic Agents/adverse effects
2.
J Endovasc Ther ; 28(5): 796-803, 2021 10.
Article in English | MEDLINE | ID: mdl-34142900

ABSTRACT

OBJECTIVES: Intraprocedural deployment of endovascular devices during complex aortic repair with 2-dimensional (2D) x-ray fluoroscopic guidance poses challenges in terms of accurate delivery system positioning and increased risk of x-ray radiation exposure with prolonged fluoroscopy times, particularly in unfavorable anatomy. The objective of this study was to assess feasibility of using an augmented reality (AR) system to position and orient a modified aortic endograft delivery system in comparison with standard fluoroscopy. MATERIALS AND METHODS: The 3-dimensional guidance, navigation, and control (3D-GNC) prototype system was developed for eventual integration with the Intra-Operative Positioning System (IOPS, Centerline Biomedical, Cleveland, OH) to project spatially registered 3D holographic representations of the subject-specific aorta for intraoperative guidance and coupled with an electromagnetically (EM) tracked delivery system for intravascular navigation. Numerical feedback for controlling the endograft landing zone distance and ostial alignment was holographically projected on the operative field. Visualization of the holograms was provided via a commercially available AR headset. A Zenith Spiral-Z AAA limb stent-graft was modified with a scallop, 6 degree-of-freedom EM sensor for tracking, and radiopaque markers for fluoroscopic visualization. In vivo, 10 interventionalists independently positioned and oriented the delivery system to the ostia of renal or visceral branch vessels in anesthetized swine via open femoral artery access using 3D-GNC and standard fluoroscopic guidance. Procedure time, fluoroscopy time, cumulative air kerma, and contrast material volume were recorded for each technique. Positioning and orientation accuracy was determined by measuring the target landing-zone distance error (δLZE) and the scallop-ostium angular alignment error (θSOE) using contrast-enhanced cone beam computed tomography imaging after each positioning for each technique. Mean, standard deviation, and standard error are reported for the performance variables, and Student's t tests were used to evaluate statistically significant differences in performance mean values of 3D-GNC and fluoroscopy. RESULTS: Technical success for the use of 3D-GNC to orient and position the endovascular device at each renal-visceral branch ostium was 100%. 3D-GNC resulted in 56% decrease in procedure time in comparison with standard fluoroscopic guidance (p<0.001). The 3D-GNC system was used without fluoroscopy or contrast-dye administration. Positioning accuracy was comparable for both techniques (p=0.86), while overall orientation accuracy was improved with the 3D-GNC system by 41.5% (p=0.008). CONCLUSIONS: The holographic 3D-GNC system demonstrated improved accuracy of aortic stent-graft positioning with significant reductions in fluoroscopy time, contrast-dye administration, and procedure time.


Subject(s)
Endovascular Procedures , Animals , Aorta , Endovascular Procedures/adverse effects , Feasibility Studies , Fluoroscopy , Imaging, Three-Dimensional , Stents , Swine , Treatment Outcome , X-Rays
SELECTION OF CITATIONS
SEARCH DETAIL
...