Knee ; 18(2): 83-7, 2011 Mar.
Article in English | MEDLINE | ID: mdl-20199864

ABSTRACT

Clinical studies to examine the effect of screw divergence have not been applied to the fixation of hamstring grafts. A few previous reports have addressed the correlations between the loss of pullout strength and divergence on hamstring tendon fixation in biomechanical tests. The purpose of this study was to examine the effect of interference screw divergence on the coronal plane when digital flexor tendons were fixed with an interference screw. Twenty fresh porcine hindlimb specimens were chosen. The grafts were fixed using titanium soft tissue interference screws. The hindlimbs were divided into two groups according to the insertion method of the screw. The screw was placed along the graft parallel to the long axis of the femoral tunnel in 10 specimens (parallel placement group), and the others were placed laterally at a 15° divergent angle from the bone tunnel on the coronal plane (divergence group). The cyclic-loading test was loaded for 1500cycles. Five specimens failed because of a pull-out of the tendon in divergence group. The number of specimens that failed before the completion of cycles in the divergence group was significantly greater than that in the parallel placement group. Although the residual displacement after 1500cycles for the divergence group was greater than that for the parallel placement group, no statistically significant difference was found between the groups. This study suggests that the screw placed laterally at a 15° divergent angle on the coronal plane decreases the fixation strength of the digital flexor tendons fixed with an interference screw.


Subject(s)
Anterior Cruciate Ligament/surgery , Bone Screws , Equipment Failure Analysis , Femur/surgery , Tendons/surgery , Animals , Biomechanical Phenomena , Hindlimb , Muscle, Skeletal , Swine , Tendons/transplantation , Weight-Bearing
2.
Arthroscopy ; 20 Suppl 2: 54-9, 2004 Jul.
Article in English | MEDLINE | ID: mdl-15243426

ABSTRACT

Magnetic resonance imaging (MRI) is an effective method to evaluate cystic lesions of the knee. Intra-articular ganglia of the knee joint was considered to be rare before the advent of MRI. However, because an MRI is often used to diagnose knee pathology, the reported prevalence of intra-articular ganglia has increased. We describe two cases of an intra-articular ganglion arising from the posterior joint capsule. Both cysts appeared to be arising from the posterior cruciate ligament by both MRI as well as arthroscopy through a lateral infrapatellar portal. However, arthroscopy through a posteromedial portal revealed the cysts to originate from the posterior joint capsule. It suggests that some of the ganglion arising from the posterior cruciate ligament reported in the literature might actually be from the posterior joint capsule. To prevent recurrence of a ganglion cyst, when preoperative MRI shows the mass to be located posterior to the cruciate ligaments, we recommend that the relationship of the ganglion cyst to the posterior joint capsule be evaluated at arthroscopy through the posteromedial or posterolateral portal.


Subject(s)
Ganglion Cysts/diagnosis , Joint Capsule/pathology , Joint Diseases/diagnosis , Knee Joint , Adult , Arthroscopy , Ganglion Cysts/therapy , Humans , Joint Diseases/therapy , Magnetic Resonance Imaging , Male , Suction