1.
J Digit Imaging ; 36(5): 1987-1994, 2023 10.
Article in English | MEDLINE | ID: mdl-37349619

ABSTRACT

The purpose of this short report is to illustrate the implementation of a RIS function for balancing radiological activities and workloads between two different teams of radiologists from the same Diagnostic Department during emergency nights and holiday shifts. One group is from the main hospital, Arcispedale S.Maria Nuova di Reggio Emilia, and the other group belongs to the five minor hospitals in the district of Reggio Emilia.The implementation of a dedicated balancing function in the RIS system successfully allows the balancing of the radiological activity between two or more teams of different radiologists, while preserving the care continuity of care and the involved workers' experience and confidence in reporting.


Subject(s)
Emergency Service, Hospital , Workload , Humans , Diagnostic Imaging
2.
Phys Med Biol ; 65(11): 11NT02, 2020 06 11.
Article in English | MEDLINE | ID: mdl-32311679

ABSTRACT

This work aims to characterize the novel DRX Plus 3543C detector in terms of detective quantum efficiency (DQE) using both a mobile x-ray system called Carestream DRX Revolution Nano and a traditional x-ray system (Carestream DRX Evolution). We used the commercial system DRX Revolution Nano, equipped with a new x-ray source based on CNT technology and field emission (FE) as the electron emitter (cathode). An innovative aspect of this device is its intrinsic selection of the focal spot size. We tested the system using three IEC-specified beam qualities (RQA3, 5 and 7) in terms of modulation transfer function (MTF), normalized noise power spectra (NNPS) and DQE as defined in the IEC 62220-1-1:2015. We compared the results obtained using DRX Revolution Nano and DRX Evolution with correlation and with Bland-Altman plots to study their agreement. RQA3 MTF is slightly lower than the RQA5 and 7 curves between 0.5 and 2.5 cycles mm-1. We measured MTF values of about 0.6 at 1 lp mm-1 and about 0.28 lp mm-1 at 2 lp mm-1. The NNPS curves show a decreasing trend with the energy regarding the DRX Revolution Nano. On the other hand, the DRX Evolution NNPS curve at RQA3 is greater than the one at RQA5, but the one at RQA5 is less than the one at RQA7. The DQE(0) ranged between about 0.82 (DRX Evolution at RQA3) and 0.54 (DRX Evolution at RQA7). As expected, the squared Pearson's correlation coefficients between the two x-ray tubes were always in an optimal agreement, and Bland-Altman plots confirmed a substantial equivalence between the two physical characterizations of the wireless detector. In conclusion, we can show that the dynamic focal selection of the system equipped with CNT does not play a substantial role in image quality compared to a traditional system in terms of physical characterisation of the detector in our measurement conditions.


Subject(s)
Nanotubes, Carbon/chemistry , Radiation Dosimeters/standards , Radiography/methods , Radiography/instrumentation , Wireless Technology/instrumentation , X-Rays
3.
Biomed Phys Eng Express ; 6(2): 025008, 2020 02 18.
Article in English | MEDLINE | ID: mdl-33438634

ABSTRACT

The goal of this paper was the comparison of radiation dose and imaging quality before and after the Clarity IQ technology installation in a Philips AlluraXper FD20/20 angiography system using a Channelized Hotelling Observer model (CHO). The core characteristics of the Allura Clarity IQ technology are its real-time noise reduction algorithms (NRT) combined with state-of-the-art hardware; this technology allows to implement acquisition protocols able to significantly reduce patient entrance dose. To measure the system performances in terms of image quality we used a contrast detail phantom in a clinical scatter condition. A Leeds TO10 phantom has been imaged between two 10 cm thick homogeneous solid water slabs. Fluoroscopy images were acquired using a cerebral protocol at 3 dose levels (low, medium and high) with a field- of view (FOV) of 31 cm. Cineangiography images were acquired using a cerebral protocol at 2 fps. Thus, 4 acquisitions were obtained for the conventional technology and 4 acquisitions were taken after the Clarity IQ upgrade, for a total of 8 different image sets. A validated 40 Gabor channels CHO with an internal noise model compared the image sets. Human observers' studies were carried out to tune the internal noise parameter. We showed that the CHO did not detect any significant difference between any of the image sets acquired using the two technologies. Consequently, this x-ray imaging technology provides a non-inferior image quality with an average patient dose reduction of 57% and 28% respectively in cineangiography and fluoroscopy. The Clarity IQ installation has certainly allowed a considerable improvement in patient and staff safety, while maintaining the same image quality.


Subject(s)
Algorithms , Angiography/standards , Image Processing, Computer-Assisted/standards , Observer Variation , Phantoms, Imaging , Quality Control , Tomography, X-Ray Computed/methods , Cineangiography/methods , Fluoroscopy/methods , Humans , Radiation Dosage
4.
Radiat Prot Dosimetry ; 181(3): 277-289, 2018 Oct 01.
Article in English | MEDLINE | ID: mdl-29462366

ABSTRACT

The aim of this article was to characterise the performance of four different digital breast tomosynthesis (DBT) systems in terms of dose and image quality parameters. One of them, GE Pristina, has never been tested before. Average glandular doses were measured both in DBT and 2D full field digital mammography mode. Several phantoms were employed to perform signal difference to noise ratio, slice sensitivity profile, slice to slice incrementation, chest wall offset, z-axis geometry, artefact spread function, low contrast detectability, contrast detail evaluations, image uniformity and in-plane MTF in chest wall-nipple and in tube-travel directions. There are many differences in DBT systems explored: the angular range, detector type, reconstruction algorithms, and the presence or not of the grid. Even if it is not simple to calculate a global figure of merit, the analysis of all the collected data can be useful in a contest of a quality assurance program to define a set of values that could be used as benchmarks.


Subject(s)
Breast/diagnostic imaging , Image Processing, Computer-Assisted/standards , Mammography/instrumentation , Mammography/standards , Algorithms , Female , Humans , Image Processing, Computer-Assisted/methods , Mammography/methods , Phantoms, Imaging , Radiographic Image Enhancement , Signal-To-Noise Ratio
5.
J Digit Imaging ; 27(6): 786-93, 2014 Dec.
Article in English | MEDLINE | ID: mdl-24965275

ABSTRACT

On X-ray modalities, the information concerning the dose delivered to the patient is usually available in image headers or in structured reports stored in the picture archiving and communication system (PACS). Sometimes this information is sent in the Modality Performed Procedure Step message. By saving the information inside the Radiological Information System, it can be linked to the patient and to his/her episode/request. A software, "Gray Detector," implementing different and complementary extraction methods was developed. Query/retrieve on images header, Modality Performed Procedure Step message analysis, or the combination of the two methods were used. In order to avoid erroneous dose-protocol association, every accession number is linked to its unique report code, allowing multiple-protocols exam recognition. The adoption of different methods to extract dosimetric information makes it possible to integrate any kind of modality in a vendor/version neutral way. Linking the dosimetric information received from a modality to the patient and to the unique report code solves, for example, common problems in computed tomography exams, where the dosimetric value related to multiple segments/studies on the modality can be associated by the technician who performs the exam only to one accession number corresponding to a single study/segment. Analyses of dosimetric indexes' dependence on modality type, patient age, technician, and radiologist were performed. Linking dosimetric information to radiological information system data allows a contextualization of the former and helps to optimize the image-quality/dose ratio, thereby making it possible to take a clinical decision that is "patient-centered."


Subject(s)
Electronic Health Records/statistics & numerical data , Radiation Dosage , Radiology Information Systems/statistics & numerical data , Software/statistics & numerical data , Systems Integration , Humans
6.
Radiol Med ; 116(7): 1039-49, 2011 Oct.
Article in English, Italian | MEDLINE | ID: mdl-21424564

ABSTRACT

PURPOSE: The aim of this study was to investigate the efficacy of a dedicated software tool for automated volume measurement of breast lesions in contrast-enhanced (CE) magnetic resonance mammography (MRM). MATERIAL AND METHODS: The size of 52 breast lesions with a known histopathological diagnosis (three benign, 49 malignant) was automatically evaluated using different techniques. The volume of all lesions was measured automatically (AVM) from CE 3D MRM examinations by means of a computer-aided detection (CAD) system and compared with the size estimates based on maximum diameter measurement (MDM) on MRM, ultrasonography (US), mammography and histopathology. RESULTS: Compared with histopathology as the reference method, AVM understimated lesion size by 4% on average. This result was similar to MDM (3% understimation, not significantly different) but significantly better than US and mammographic lesion measurements (24% and 33% size underestimation, respectively). CONCLUSIONS: AVM is as accurate as MDM but faster. Both methods are more accurate for size assessment of breast lesions compared with US and mammography.


Subject(s)
Breast Neoplasms/diagnosis , Carcinoma, Intraductal, Noninfiltrating/diagnosis , Carcinoma, Lobular/diagnosis , Diagnosis, Computer-Assisted , Magnetic Resonance Imaging , Mammography , Adult , Aged , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Carcinoma, Ductal, Breast/diagnosis , Carcinoma, Intraductal, Noninfiltrating/diagnostic imaging , Carcinoma, Intraductal, Noninfiltrating/pathology , Carcinoma, Lobular/diagnostic imaging , Carcinoma, Lobular/pathology , Contrast Media , Female , Humans , Mammography/methods , Middle Aged , Predictive Value of Tests , Retrospective Studies , Sensitivity and Specificity , Ultrasonography