Eur Urol Focus ; 6(1): 131-136, 2020 01 15.
Article in English | MEDLINE | ID: mdl-30293945

ABSTRACT

BACKGROUND: Although effective for benign prostatic hyperplasia (BPH), transurethral resection of the prostate (TURP) can be associated with side effects including prolonged recovery, storage and voiding symptoms, and a risk of acute urinary retention. OBJECTIVE: To test a new minimally invasive device for the treatment of lower urinary tract symptoms (LUTS) due to BPH, involving implantation of a C-shaped nitinol ring (ClearRing) in a circular incision in the prostatic tissue using an electrocuting blade over a dilatation balloon. DESIGN, SETTING, AND PARTICIPANTS: This was a multicenter single-arm clinical trial involving 29 men with severe symptomatic BPH. INTERVENTION: Implantation of a ClearRing device under regional anesthesia. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Effectiveness in alleviating LUTS was assessed in terms of International Prostate Symptom Score (IPSS) at baseline and 3, 6, and 12 mo after the procedure. To evaluate changes from baseline, a general estimating equation model was fitted to IPSS, the Quality of Life (QOL) scale, Benign Prostatic Hyperplasia Impact Index, maximum flow rate (Qmax), and postvoid residual volume. Statistical significance was defined as p<0.05. RESULTS AND LIMITATIONS: The average age was 71.4 yr, prostate size was 35-50cm3, and IPSS was 21.6. All procedures were successfully completed with one implant in 28 patients and two implants in one patient. No serious complications occurred. Patients experienced symptom relief by 3 mo that was sustained to 12 mo. Mean IPSS, QOL, and Qmax improved by 45%, 41%, and 40% by 3 mo, and 53%, 52%, and 49% by 12 mo, respectively (p<0.05). Adverse events were mild and transient. There were no reports of loss of antegrade ejaculation or any effects on erectile function. Implantation positioning failed in 11/29 patients, who then underwent uneventful TURP. After modification of the delivery device, the success rate for implant positioning improved from 5/13 patients to 13/16 patients. Study limitations include the single-arm nature and the low patient number. CONCLUSIONS: We demonstrated preliminary feasibility of the ClearRing device for minimally invasive treatment of BPH in men. Further studies are needed to confirm the safety and efficacy of this approach. PATIENT SUMMARY: In this study we tested outcomes after implantation of a ClearRing device in patients with benign prostatic hyperplasia. We found that the device was safe and effective. However, there was a high rate of implantation failure due to malpositioning, which was significantly improved following modification of the delivery device.


Subject(s)
Lower Urinary Tract Symptoms/surgery , Prostatic Hyperplasia/surgery , Prostheses and Implants , Aged , Aged, 80 and over , Alloys , Humans , Lower Urinary Tract Symptoms/etiology , Male , Middle Aged , Prospective Studies , Prostatic Hyperplasia/complications , Prostheses and Implants/adverse effects , Prosthesis Design , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...