Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
ACS Appl Mater Interfaces ; 16(21): 27821-27830, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38747496

ABSTRACT

For practical industrial applications, enhancing the longevity and the reliability of thermoelectric modules (TEMs) is equally as crucial as improving their conversion efficiency. This study proposes a strategy for extending the lifespan and introduces the quality evaluation criteria for the most extensively used commercial bismuth telluride TEM. By varying the soldering pressure during module assembly, its impact on the quality of the module's internal interfacial connections was investigated, via analyzing its contact resistivity, shear modulus, and antifatigue ability through thermal cycling tests. The findings reveal that increasing the soldering pressure leads to a slight reduction in interfacial contact resistivity and has no significant effect on the shear modulus but notably enhances the module's antifatigue ability during thermal cycling tests. According to the SEM results, it can be evidently deduced that the aforementioned phenomena are directly correlated with the size and quantity of voids distributed in the solder layer, which is regarded as the origin of antifatigue ability. Thus, it can be inferred that augmenting the soldering pressure represents an effective approach to prolonging the lifespan of TEMs assembled by using the soldering method. Furthermore, the existence of voids within the solder layer can serve as a criterion for an initial assessment of module longevity. This study provides a reference for both the industrial assembly and lifespan evaluation of commercial bismuth telluride TEMs.

2.
Small ; : e2401078, 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38593301

ABSTRACT

Currently, the only thermoelectric (TE) materials commercially available at room temperature are those based on bismuth telluride. However, their widespread application is limited due to their inferior thermoelectric and mechanical properties. In this study, a strategy of growing a rigid second phase of MoSe2 is employed, in situ within the matrix phase to achieve n-type bismuth telluride-based materials with exceptional mechanical and thermoelectric properties. The in situ grown second phase contributes to both the electronic and lattice thermal conductivities. This is primarily attributed to the strong energy filtering effect, as the second phase forms a semi-common lattice interfacial structure with the matrix phase during growth. Furthermore, for composites containing 2 wt% MoSe2, a maximum zT value of 1.24 at 373 K can be achieved. On this basis, 8-pair TE module is fabricated and 1-pair TE module is optimized using a homemade p-type material. The optimized 1-pair TE module generates a maximum output power of 13.6 µW, which is twice that of the 8-pair TE module and four times more than the 8-pair TE module fabricated by commercial material. This work facilitates the development of the TE module by presenting a novel approach to obtaining bismuth telluride-based thermoelectric materials with superior thermoelectric and mechanical properties.

3.
ACS Appl Mater Interfaces ; 16(1): 1137-1147, 2024 Jan 10.
Article in English | MEDLINE | ID: mdl-38154044

ABSTRACT

As a result of the complexity and difficulty of the lifetime assessment of the thermoelectric (TE) module, the related research is still immature. In this work, to predict the lifetime of the Bi2Te3-based TE module from the perspective of cyclic thermal stress leading to interface cracking, the viscoplastic behavior of the solder layer is first described by the Anand material ontology model, and then the sprouting and expansion of interface cracking of the module are simulated by combining the Darveaux model and the viscoplastic dissipation energy accumulated during the thermal stress cyclic loading. After that, the complete lifetime prediction model of the TE module is established on the basis of the thermal cycling experiments and the finite element simulation calculation data, which can simply and efficiently predict the cycle number of the module resistance rise and its rise rate. The prediction deviations are 6.1 and 6.7%, respectively, verifying the feasibility of the model. The work in this paper can provide a reference for the life evaluation of TE modules.

4.
ACS Appl Mater Interfaces ; 14(36): 41588-41597, 2022 Sep 14.
Article in English | MEDLINE | ID: mdl-36048715

ABSTRACT

Due to the uncertainty of the brazing solder composition and its unknown effect on the long-term stability of the interface, the brazing interface connection process for half-Heusler (hH) thermoelectric (TE) devices is still partially concealed and incomplete. In this work, we selected different types of Ag-Cu-based brazing solders with different Ag and Cu contents to assemble hH TE devices, observed the microstructure of the interface contact, and analyzed its formation mechanism. It is found that when the Cu element in the brazing solder is high, it tends to form an intermetallic compound (IMC) layer at the interface, which threatens the life of the device. On the contrary, when the content of the Ag element is high, the formation of the IMC layer will be avoided. Then, the long-term stability of the interface brazed by Ag72Cu28 with high Ag content was verified: the interface connection showed good contact resistivity stability and mechanical reliability; the fabricated uni-couple TE module achieved a maximum output power of 0.28 W and a maximum conversion efficiency of 7.34% at a temperature difference of 538 K. This work summarizes the selection principle of Cu-Ag-based brazing solder when assembling hH TE modules and verifies the long-term stability of the brazed connection interface. The experiment results can provide a reference for the actual fabrication of hH TE devices.

5.
Rev Sci Instrum ; 86(2): 024704, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25725867

ABSTRACT

A new design of DC hybrid circuit breaker based on high-speed switch (HSS) and arc generator (AG), which can drastically profit from low heat loss in normal state and fast current breaking under fault state, is presented and analyzed in this paper. AG is designed according to the magnetic pinch effect of liquid metal. By utilizing the arc voltage generated across AG, the fault current is rapidly commutated from HSS into parallel connected branch. As a consequence, the arcless open of HSS is achieved. The post-arc conducting resume time (Δ tc) of AG and the commutation original voltage (Uc), two key factors in the commutation process, are investigated experimentally. Particularly, influences of the liquid metal channel diameter (Φ) of AG, fault current rate of rise (di/dt) and Uc on Δ tc are focused on. Furthermore, a suitable Uc is determined during the current commutation process, aiming at the reliable arcless open of HSS and short breaking time. Finally, the fault current breaking test is carried out for the current peak value of 11.8 kA, and the validity of the design is confirmed by the experimental results.

6.
Rev Sci Instrum ; 85(8): 084707, 2014 Aug.
Article in English | MEDLINE | ID: mdl-25173295

ABSTRACT

The DC hybrid circuit breaker based on high-speed switch (HSS) and parallel connected capacitor has been widely applied in the fault current breaking of DC system. However, when the current is commutated from HSS to the capacitor according to single-stage operation, the capacitor has to absorb a large amount of energy stored in the system inductance within very short time. Meanwhile, a high over-voltage rate of rise is especially prone to be produced between the contacts of HSS, which will lead to a failed breaking. As a result, a novel DC hybrid circuit breaker based on the two-stage operation is proposed and analyzed in this paper. By controlling the thyristors in the commutation branches, the fault current is fast commutated into the capacitor, which can not only realize the arcless open of HSS, but also decrease the over-voltage rate of rise significantly in comparison to the traditional single-stage operation. The simulation model of fault current breaking under different conditions in 10 kV medium voltage DC system is constructed. The simulated over-voltages of single-stage and two-stage operations in the case of fault current breaking are compared and analyzed. Finally, the fault current breaking test in the two-stage operation is investigated experimentally, which validates the feasibility and effectiveness of the simulation model well.

SELECTION OF CITATIONS
SEARCH DETAIL
...