1.
J Hosp Infect ; 148: 1-10, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38447806

ABSTRACT

BACKGROUND: Many UK hospitals rely heavily on natural ventilation as their main source of airflow in patient wards. This method of ventilation can have cost and energy benefits, but it may lead to unpredictable flow patterns between indoor spaces, potentially leading to the unexpected transport of infectious material to other connecting zones. However, the effects of weather conditions on airborne transmission are often overlooked. METHODS: A multi-zone CONTAM model of a naturally ventilated hospital respiratory ward, incorporating time-varying weather, was proposed. Coupling this with an airborne infection model, this study assessed the variable risk in interconnected spaces, focusing particularly on occupancy, disease and ventilation scenarios based on a UK respiratory ward. RESULTS: The results suggest that natural ventilation with varying weather conditions can cause irregularities in the ventilation rates and interzonal flow rates of connected zones, leading to infrequent but high peaks in the concentration of airborne pathogens in particular rooms. This transient behaviour increases the risk of airborne infection, particularly through movement of pathogens between rooms, and highlights that large outbreaks may be more likely under certain conditions. This study demonstrated how ventilation rates achieved by natural ventilation are likely to fall below the recommended guidance, and that the implementation of supplemental mechanical ventilation can increase ventilation rates and reduce the variability in infection risks. CONCLUSION: This model emphasises the need for consideration of transient external conditions when assessing the risk of transmission of airborne infection in indoor environments.


Subject(s)
Air Microbiology , Cross Infection , Hospitals , Ventilation , Weather , Humans , Cross Infection/transmission , United Kingdom/epidemiology , Air Pollution, Indoor , Risk Assessment
2.
Environ Sci Technol ; 56(2): 1125-1137, 2022 01 18.
Article in English | MEDLINE | ID: mdl-34985868

ABSTRACT

Some infectious diseases, including COVID-19, can undergo airborne transmission. This may happen at close proximity, but as time indoors increases, infections can occur in shared room air despite distancing. We propose two indicators of infection risk for this situation, that is, relative risk parameter (Hr) and risk parameter (H). They combine the key factors that control airborne disease transmission indoors: virus-containing aerosol generation rate, breathing flow rate, masking and its quality, ventilation and aerosol-removal rates, number of occupants, and duration of exposure. COVID-19 outbreaks show a clear trend that is consistent with airborne infection and enable recommendations to minimize transmission risk. Transmission in typical prepandemic indoor spaces is highly sensitive to mitigation efforts. Previous outbreaks of measles, influenza, and tuberculosis were also assessed. Measles outbreaks occur at much lower risk parameter values than COVID-19, while tuberculosis outbreaks are observed at higher risk parameter values. Because both diseases are accepted as airborne, the fact that COVID-19 is less contagious than measles does not rule out airborne transmission. It is important that future outbreak reports include information on masking, ventilation and aerosol-removal rates, number of occupants, and duration of exposure, to investigate airborne transmission.


Subject(s)
Air Pollution, Indoor , COVID-19 , Aerosols , Disease Outbreaks , Humans , SARS-CoV-2 , Ventilation
3.
J Hosp Infect ; 109: 44-51, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33271214

ABSTRACT

BACKGROUND: Healthcare worker (HCW) behaviours, such as the sequence of their contacts with surfaces and hand hygiene moments, are important for understanding disease transmission. AIM: To propose a method for recording sequences of HCW behaviours during mock vs actual procedures, and to evaluate differences for use in infection risk modelling and staff training. METHODS: Procedures for three types of care were observed under mock and actual settings: intravenous (IV) drip care, observational care and doctors' rounds on a respiratory ward in a university teaching hospital. Contacts and hand hygiene behaviours were recorded in real-time using either a handheld tablet or video cameras. FINDINGS: Actual patient care demonstrated 70% more surface contacts than mock care. It was also 2.4 min longer than mock care, but equal in terms of patient contacts. On average, doctors' rounds took 7.5 min (2.5 min for mock care), whilst auxiliary nurses took 4.9 min for observational care (2.4 min for mock care). Registered nurses took 3.2 min for mock IV care and 3.8 min for actual IV care; this translated into a 44% increase in contacts. In 51% of actual care episodes and 37% of mock care episodes, hand hygiene was performed before patient contact; in comparison, 15% of staff delivering actual care performed hand hygiene after patient contact on leaving the room vs 22% for mock care. The number of overall touches in the patient room was a modest predictor of hand hygiene. Using a model to predict hand contamination from surface contacts for Staphylococcus aureus, Escherichia coli and norovirus, mock care underestimated micro-organisms on hands by approximately 30%.


Subject(s)
Cross Infection , Hand Hygiene , Infection Control , Guideline Adherence , Hand , Hand Disinfection , Health Personnel , Humans , Patient Care , Patient Simulation , Patients' Rooms
4.
Sci Rep ; 10(1): 11841, 2020 07 16.
Article in English | MEDLINE | ID: mdl-32678236

ABSTRACT

In the context of increasingly airtight homes, there is currently little known about the type and diversity of microorganisms in the home, or factors that could affect their abundance, diversity and nature. In this study, we examined the type and prevalence of cultivable microorganisms at eight different sites in 100 homes of older adults located in Glasgow, Scotland. The microbiological sampling was undertaken alongside a household survey that collated information on household demographics, occupant behaviour, building characteristics, antibiotic use and general health information. Each of the sampled sites revealed its own distinct microbiological character, in both species and number of cultivable microbes. While some potential human pathogens were identified, none were found to be multidrug resistant. We examined whether the variability in bacterial communities could be attributed to differences in building characteristics, occupant behaviour or household factors. Sampled sites furnished specific microbiological characteristics which reflected room function and touch frequency. We found that homes that reported opening windows more often were strongly associated with lower numbers of Gram-negative organisms at indoor sites (p < 0.0001). This work offers one of the first detailed analysis of cultivable microbes in homes of older adults and their relationship with building and occupancy related factors, in a UK context.


Subject(s)
Air Pollution, Indoor/analysis , Bacillaceae/isolation & purification , Bacteria/growth & development , Housing , Micrococcaceae/isolation & purification , Staphylococcaceae/isolation & purification , Activities of Daily Living , Aged , Bacillaceae/classification , Family Characteristics , Fomites/microbiology , Humans , Micrococcaceae/classification , Scotland , Staphylococcaceae/classification , Touch/physiology , Ventilation
6.
Waste Manag ; 80: 154-167, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30454995

ABSTRACT

This study investigated the performance of four pilot-scale biofilters for the removal of bioaerosols from waste airstreams in a materials recovery facility (MRF) based in Leeds, UK. A six-stage Andersen sampler was used to measure the concentrations of four groups of bioaerosols (Aspergillus fumigatus, total fungi, total mesophilic bacteria and Gram negative bacteria) in the airstream before and after passing through the biofilters over a period of 11 months. The biofilters achieved average removal efficiency (RE) of 70% (35 to 97%) for A. fumigatus, 71% (35 to 94%) for total fungi, 68% (47 to 86%) for total mesophilic bacteria and 50% (-4 to 85%) for Gram negative bacteria, provided that the inlet concentration was high (103-105 cfu m-3), which is the case for most waste treatment facilities. The performance was highly variable at low inlet concentration with some cases showing an increase in outlet concentrations, suggesting that biofilters had the potential to be net emitters of bioaerosols. The gas phase residence time did not appear to have any statistically significant impact on bioaerosol removal efficiency. Particle size distribution varied between the inlet and outlet air, with the outlet having a greater proportion of smaller sized particles that represent a greater human health risk as they can penetrate deep into the respiratory system where gaseous exchange occurs. However, the outlet concentrations were low and would further be diluted by wind in full scale applications. In conclusion, this study shows that biofilters designed and operated for odour degradation can also achieve significant bioaerosol control in waste gas.


Subject(s)
Odorants , Wind , Filtration , Fungi , Humans
7.
J Hosp Infect ; 100(3): e123-e129, 2018 Nov.
Article in English | MEDLINE | ID: mdl-29649556

ABSTRACT

BACKGROUND: There are few data and no accepted standards for air quality in the intensive care unit (ICU). Any relationship between airborne pathogens and hospital-acquired infection (HAI) risk in the ICU remains unknown. AIM: First, to correlate environmental contamination of air and surfaces in the ICU; second, to examine any association between environmental contamination and ICU-acquired staphylococcal infection. METHODS: Patients, air, and surfaces were screened on 10 sampling days in a mechanically ventilated 10-bed ICU for a 10-month period. Near-patient hand-touch sites (N = 500) and air (N = 80) were screened for total colony count and Staphylococcus aureus. Air counts were compared with surface counts according to proposed standards for air and surface bioburden. Patients were monitored for ICU-acquired staphylococcal infection throughout. FINDINGS: Overall, 235 of 500 (47%) surfaces failed the standard for aerobic counts (≤2.5 cfu/cm2). Half of passive air samples (20/40: 50%) failed the 'index of microbial air' contamination (2 cfu/9 cm plate/h), and 15/40 (37.5%) active air samples failed the clean air standard (<10 cfu/m3). Settle plate data were closer to the pass/fail proportion from surfaces and provided the best agreement between air parameters and surfaces when evaluating surface benchmark values of 0-20 cfu/cm2. The surface standard most likely to reflect hygiene pass/fail results compared with air was 5 cfu/cm2. Rates of ICU-acquired staphylococcal infection were associated with surface counts per bed during 72h encompassing sampling days (P = 0.012). CONCLUSION: Passive air sampling provides quantitative data analogous to that obtained from surfaces. Settle plates could serve as a proxy for routine environmental screening to determine the infection risk in ICU.


Subject(s)
Cross Infection/epidemiology , Cross Infection/microbiology , Environmental Microbiology , Intensive Care Units , Staphylococcal Infections/epidemiology , Staphylococcal Infections/microbiology , Staphylococcus aureus/isolation & purification , Colony Count, Microbial , Humans
8.
J Hosp Infect ; 94(1): 48-51, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27392977

ABSTRACT

This study quantifies the relationship between hand hygiene and the frequency with which healthcare workers (HCWs) touch surfaces in patient rooms. Surface contacts and hand hygiene were recorded in a single-bed UK hospital ward for six care types. Surface contacts often formed non-random patterns, but hygiene before or after patient contact depends significantly on care type (P=0.001). The likelihood of hygiene correlated with the number of surface contacts (95% confidence interval 1.1-5.8, P=0.002), but not with time spent in the room. This highlights that a potential subconscious need for hand hygiene may have developed in HCWs, which may support and help focus future hygiene education programmes.


Subject(s)
Attitude of Health Personnel , Cross Infection/prevention & control , Disease Transmission, Infectious/prevention & control , Hand Hygiene/methods , Infection Control/methods , Touch , Humans , Patients' Rooms , United Kingdom
9.
Indoor Air ; 25(6): 694-707, 2015 Dec.
Article in English | MEDLINE | ID: mdl-25614923

ABSTRACT

UNLABELLED: Aerial dispersion of pathogens is recognized as a potential transmission route for hospital acquired infections; however, little is known about the link between healthcare worker (HCW) contacts' with contaminated surfaces, the transmission of infections and hospital room design. We combine computational fluid dynamics (CFD) simulations of bioaerosol deposition with a validated probabilistic HCW-surface contact model to estimate the relative quantity of pathogens accrued on hands during six types of care procedures in two room types. Results demonstrate that care type is most influential (P < 0.001), followed by the number of surface contacts (P < 0.001) and the distribution of surface pathogens (P = 0.05). Highest hand contamination was predicted during Personal care despite the highest levels of hand hygiene. Ventilation rates of 6 ac/h vs. 4 ac/h showed only minor reductions in predicted hand colonization. Pathogens accrued on hands decreased monotonically after patient care in single rooms due to the physical barrier of bioaerosol transmission between rooms and subsequent hand sanitation. Conversely, contamination was predicted to increase during contact with patients in four-bed rooms due to spatial spread of pathogens. Location of the infectious patient with respect to ventilation played a key role in determining pathogen loadings (P = 0.05). PRACTICAL IMPLICATIONS: We present the first quantitative model predicting the surface contacts by HCW and the subsequent accretion of pathogenic material as they perform standard patient care. This model indicates that single rooms may significantly reduce the risk of cross-contamination due to indirect infection transmission. Not all care types pose the same risks to patients, and housekeeping performed by HCWs may be an important contribution in the transmission of pathogens between patients. Ventilation rates and positioning of infectious patients within four-bed rooms can mitigate the accretion of pathogens, whereby reducing the risk of missed hand hygiene opportunities. The model provides a tool to quantitatively evaluate the influence of hospital room design on infection risk.


Subject(s)
Cross Infection/transmission , Models, Biological , Cross Infection/prevention & control , Hand Disinfection , Humans , Hydrodynamics , Infectious Disease Transmission, Professional-to-Patient , Patient Care , Patients' Rooms , Ventilation
10.
J Clin Endocrinol Metab ; 99(12): E2702-8, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25140394

ABSTRACT

CONTEXT: SOX3 is an early developmental transcription factor involved in pituitary development. In humans, over- and underdosage of SOX3 is associated with X-linked hypopituitarism with variable phenotypes ranging from isolated GH deficiency (GHD) to panhypopituitarism, with or without mental retardation and, in most cases, with reported pituitary imaging, an ectopic/undescended posterior pituitary. PATIENT: We present a young patient with hemophilia B and developmental delay who had a 2.31-Mb deletion on Xq27 including SOX3, F9, and eight other contiguous genes. He developed GH and gonadotropin deficiency, whilst his thyroid function was in the low normal range. Magnetic resonance imaging revealed a eutopic posterior pituitary and the unusual finding of a persistent craniopharyngeal canal that has not previously been described in patients with congenital hypopituitarism. OBJECTIVE AND METHODS: To establish whether loss of SOX3 can account for the human phenotype, we examined in detail the hypothalamo-pituitary region of neonatal Sox3 null mice. RESULTS: Consistent with the patient's phenotype, Sox3 null mice exhibit a ventral extension of the anterior pituitary that penetrates, and generates a mass beneath, the sphenoid bone. This suggests that the defect results from abnormal induction of Rathke's pouch, leading to a persistent connection between Rathke's pouch and the oral ectoderm. CONCLUSIONS: Our observations expand the spectrum of phenotypes observed in association with altered SOX3 dosage and may affect the approach to genetic screening. Screening for SOX3 should be advised not only for hypopituitary patients with an ectopic posterior pituitary, but also for those with a structurally normal pituitary and additional findings, including clefts and a persistent craniopharyngeal canal, with or without mental retardation.


Subject(s)
Gene Deletion , SOXB1 Transcription Factors/genetics , Sphenoid Bone/abnormalities , Sphenoid Bone/growth & development , Animals , Child, Preschool , Developmental Disabilities/genetics , Hemophilia B/genetics , Humans , Hypopituitarism/genetics , Hypopituitarism/pathology , Hypothalamo-Hypophyseal System/abnormalities , Hypothalamo-Hypophyseal System/pathology , Male , Mice , Mice, Knockout , Pituitary Gland/pathology , Sphenoid Bone/pathology
11.
J Hosp Infect ; 77(3): 213-22, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21194796

ABSTRACT

With concerns about the potential for the aerosol and airborne transmission of infectious agents, particularly influenza, more attention is being focused on the effectiveness of infection control procedures to prevent hospital-acquired infections by this route. More recently a number of different techniques have been applied to examine the temporal-spatial information about the airflow patterns and the movement of related, suspended material within this air in a hospital setting. Closer collaboration with engineers has allowed clinical microbiologists, virologists and infection control teams to assess the effectiveness of hospital isolation and ventilation facilities. The characteristics of human respiratory activities have also been investigated using some familiar engineering techniques. Such studies aim to enhance the effectiveness of such preventive measures and have included experiments with human-like mannequins using various tracer gas/particle techniques, real human volunteers with real-time non-invasive Schlieren imaging, numerical modelling using computational fluid dynamics, and small scale physical analogues with water. This article outlines each of these techniques in a non-technical manner, suitable for a clinical readership without specialist airflow or engineering knowledge.


Subject(s)
Aerosols , Air Movements , Cross Infection/prevention & control , Exhalation , Infection Control/methods , Air Microbiology , Air Pollution, Indoor , Communicable Disease Control , Cross Infection/transmission , Humans , Hydrodynamics , Ventilation
12.
Build Environ ; 46(12): 2500-2511, 2011 Dec.
Article in English | MEDLINE | ID: mdl-32288014

ABSTRACT

Computational Fluid Dynamics (CFD) is an increasingly popular tool for studying the impact of design interventions on the transport of infectious microorganisms. While much of the focus is on respiratory infections, there is substantial evidence that certain pathogens, such as those which colonise the skin, can be released into, and transported through the air through routine activities. In these situations the bacteria is released over a volume of space, with different intensities and locations varying in time rather than being released at a single point. This paper considers the application of CFD modelling to the evaluation of risk from this type of bioaerosol generation. An experimental validation study provides a direct comparison between CFD simulations and bioaerosol distribution, showing that passive scalar and particle tracking approaches are both appropriate for small particle bioaerosols. The study introduces a zonal source, which aims to represent the time averaged release of bacteria from an activity within a zone around the entire location the release takes place. This approach is shown to perform well when validated numerically though comparison with the time averaged dispersion patterns from a transient source. However, the ability of a point source to represent such dispersion is dependent on airflow regime. The applicability of the model is demonstrated using a simulation of an isolation room representing the release of bacteria from bedmaking.

13.
Clin Genet ; 80(5): 435-43, 2011 Nov.
Article in English | MEDLINE | ID: mdl-21114665

ABSTRACT

We describe the identification and clinical presentation of four individuals from three unrelated families with hemizygous deletions involving the DPYD gene at chromosome 1p21.3. DPYD encodes dihydropyrimidine dehydrogenase, which is the initial and rate-limiting enzyme in the catabolism of pyrimidine bases. All four individuals described met diagnostic criteria for autism spectrum disorder with severe speech delay. Patient 1's deletion was originally reported in 2008, and more detailed clinical information is provided. Subsequently, this male individual was found to have a missense mutation in the X-linked PTCHD1 autism susceptibility gene, which may also contribute to the phenotype. Patients 2 and 3 are siblings with a novel deletion encompassing the DPYD gene. In their mother, the genomic region deleted from chromosome 1p21.3 was inserted into chromosome 10. A fourth proband had a novel 10-kb intragenic deletion of exon 6 of the DPYD gene detected on a higher resolution microarray. Our study suggests that hemizygous deletions involving the DPYD locus present with variable phenotypes which can include speech delay and autistic features, and may also be influenced by additional mutations in other genes, issues which need to be considered in genetic counseling.


Subject(s)
Child Development Disorders, Pervasive/genetics , Chromosomes, Human, Pair 1/genetics , Dihydrouracil Dehydrogenase (NADP)/genetics , Adolescent , Adult , Child , Child, Preschool , Chromosome Deletion , Chromosomes, Human, Pair 10/genetics , Female , Humans , Male , Pedigree
14.
Epidemiol Infect ; 134(5): 1082-91, 2006 Oct.
Article in English | MEDLINE | ID: mdl-16476170

ABSTRACT

The Wells-Riley equation for modelling airborne infection in indoor environments is incorporated into an SEIR epidemic model with a short incubation period to simulate the transmission dynamics of airborne infectious diseases in ventilated rooms. The model enables the effect of environmental factors such as the ventilation rate and the room occupancy to be examined, and allows the long-term impact of infection control measures to be assessed. A theoretical parametric study is carried out to demonstrate how changes to both the physical environment and infection control procedures may potentially limit the spread of short-incubation-period airborne infections in indoor environments such as hospitals.


Subject(s)
Air Microbiology , Infections/transmission , Models, Statistical , Air Pollution, Indoor/analysis , Community-Acquired Infections/transmission , Cross Infection/transmission , Disease Outbreaks , Humans , Risk Assessment , Ventilation
15.
Int J Tuberc Lung Dis ; 7(11): 1015-26, 2003 Nov.
Article in English | MEDLINE | ID: mdl-14598959

ABSTRACT

Tuberculosis (TB) is a disease that is closely associated with poverty, with transmission occurring in situations where infected persons are in close contact with others in confined spaces. While it is well recognised that overcrowding increases the risk of transmission, this increased risk has not been quantified and the relationship between overcrowding and duration of exposure is not well understood. This paper analyses three epidemiological models that have been used to predict the transmission of airborne disease in confined spaces: the Mass Action model, Riley, Murphy and Riley's model and Gammaitoni and Nucci's model. A study is presented to demonstrate the range of applicability of each model and show how they can be applied to the transmission of both TB and diseases with short incubation periods such as measles. Gammiatoni and Nucci's generalised formulation is shown to be the most suitable for modelling airborne transmission in ventilated spaces, and it is subsequently used in a parametric study to evaluate the effect of physical and environmental factors on the rate of disease transmission. The paper also presents reported quanta production data for several TB outbreaks and demonstrates that the greatest risk of TB infection is during clinical procedures that produce large quantities of aerosol, such as bronchoscopy or intubation.


Subject(s)
Disease Transmission, Infectious/statistics & numerical data , Models, Statistical , Tuberculosis, Pulmonary/epidemiology , Tuberculosis, Pulmonary/transmission , Environmental Exposure , Humans , Population Density , Risk Assessment , Risk Factors , Time Factors
16.
Microsc Res Tech ; 47(3): 172-81, 1999 Nov 01.
Article in English | MEDLINE | ID: mdl-10544332

ABSTRACT

The ability to visualize cell motility occurring deep in the context of opaque tissues will allow many currently intractable issues in developmental biology and organogenesis to be addressed. In this study, we compare two-photon excitation with laser scanning confocal and conventional digital deconvolution fluorescence microscopy, using the same optical configuration, for their ability to resolve cell shape deep in Xenopus gastrula and neurula tissues. The two-photon microscope offers better depth penetration and less autofluorescence compared to confocal and conventional deconvolution imaging. Both two-photon excitation and confocal microscopy also provide improved rejection of "out-of-focus" noise and better lateral and axial resolution than conventional digital deconvolution microscopy. Deep Xenopus cells are best resolved by applying the digital deconvolution method on the two-photon images. We have also found that the two-photon has better depth penetration without any degradation in the image quality of interior sections compared to the other two techniques. Also, we have demonstrated that the quality of the image changes at different depths for various excitation powers.


Subject(s)
Image Enhancement/methods , Microscopy, Confocal/methods , Microscopy, Fluorescence/methods , Xenopus/embryology , Animals , Embryo, Nonmammalian , Morphogenesis , Photons