Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
PLoS One ; 16(12): e0256115, 2021.
Article in English | MEDLINE | ID: mdl-34914710

ABSTRACT

INTRODUCTION: A fetal anomaly scan in mid-pregnancy is performed, to check for the presence of congenital anomalies, including congenital heart disease (CHD). Unfortunately, 40% of CHD is still missed. The combined use of ultrasound and electrocardiography might boost detection rates. The electrical heart axis is one of the characteristics which can be deduced from an electrocardiogram (ECG). The aim of this study was to determine reference values for the electrical heart axis in healthy fetuses around 20 weeks of gestation. MATERIAL AND METHODS: Non-invasive fetal electrocardiography was performed subsequent to the fetal anomaly scan in pregnant women carrying a healthy singleton fetus between 18 and 24 weeks of gestation. Eight adhesive electrodes were applied on the maternal abdomen including one ground and one reference electrode, yielding six channels of bipolar electrophysiological measurements. After removal of interferences, a fetal vectorcardiogram was calculated and then corrected for fetal orientation. The orientation of the electrical heart axis was determined from this normalized fetal vectorcardiogram. Descriptive statistics were used on normalized cartesian coordinates to determine the average electrical heart axis in the frontal plane. Furthermore, 90% prediction intervals (PI) for abnormality were calculated. RESULTS: Of the 328 fetal ECGs performed, 281 were included in the analysis. The average electrical heart axis in the frontal plane was determined at 122.7° (90% PI: -25.6°; 270.9°). DISCUSSION: The average electrical heart axis of healthy fetuses around mid-gestation is oriented to the right, which is, due to the unique fetal circulation, in line with muscle distribution in the fetal heart.


Subject(s)
Electrocardiography , Fetal Heart , Fetus , Prenatal Diagnosis , Adolescent , Adult , Cohort Studies , Female , Humans , Pregnancy
2.
Obstet Gynecol Surv ; 75(6): 369-380, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32603475

ABSTRACT

IMPORTANCE: The introduction of the cardiotocogram (CTG) during labor has not been found to improve neonatal outcome. The search for a more reliable, less invasive, and patient-friendly technique is ongoing. The noninvasive fetal electrocardiogram (NI-fECG) has been proposed as one such alternative. OBJECTIVES: The aim of this study was to review the literature on the performance of NI-fECG for fetal monitoring during labor. Following the PRISMA guidelines, a systematic search in MEDLINE, EMBASE, and Cochrane Library was performed. Studies involving original research investigating the performance of NI-fECG during labor were included. Animal studies and articles in languages other than English, Dutch, or German were excluded. The QUADAS-2 checklist was used for quality assessment. A descriptive analysis of the results is provided. RESULTS: Eight articles were included. Pooled analysis of the results of the separate studies was not possible due to heterogeneity. All studies demonstrate that it is possible to apply NI-fECG during labor. Compared with Doppler ultrasound, NI-fECG performs equal or better in most studies. CONCLUSIONS AND RELEVANCE: NI-fECG for fetal monitoring is a promising noninvasive and patient-friendly technique that provides accurate information. Future studies should focus on signal quality throughout labor, with the aim to further optimize technical development of NI-fECG.


Subject(s)
Electrocardiography/methods , Fetal Heart/physiology , Heart Rate, Fetal , Female , Humans , Labor, Obstetric , Pregnancy , Reproducibility of Results , Signal-To-Noise Ratio
3.
BMC Pregnancy Childbirth ; 20(1): 215, 2020 Apr 15.
Article in English | MEDLINE | ID: mdl-32293330

ABSTRACT

BACKGROUND: Twin pregnancy is associated with increased perinatal mortality. Close foetal monitoring is therefore warranted. Doppler Ultrasound cardiotocography is currently the only available method to monitor both individual foetuses. Unfortunately, the performance measures of this method are poor and erroneous monitoring of the same twin with both transducers may occur, leaving the second twin unmonitored. In this study we aimed to determine the feasibility of monitoring both foetuses simultaneously in twin gestation by means of non-invasive foetal electrocardiography (NI-fECG), using an electrode patch on the maternal abdomen. METHODS: A NI-fECG recording was performed at 25 + 3 weeks of gestation on a multiparous woman pregnant with dichorionic diamniotic twins. An electrode patch consisting of eight adhesive electrodes was applied on the maternal abdomen, yielding six channels of bipolar electrophysiological measurements. The output was digitized and stored for offline processing. The recorded signals were preprocessed by suppression of high-frequency noise, baseline wander, and powerline interference. Secondly, the maternal ECG was subtracted and segmentation into individual ECG complexes was performed. Finally, ensemble averaging of these individual ECG complexes was performed to suppress interferences. RESULTS: Six different recordings were obtained from each of the six recording channels. Depending on the orientation and distance of the fetal heart with respect to each electrode, a distinction could be made between each fetus based on the morphology of the signals. Yielding of the fetal ECGs was performed manually based on the QRS complexes of each fetus. CONCLUSION: NI-fECG with multiple electrodes allows for monitoring of the fetal heart rate and ECG of both individual fetuses in twin pregnancies.


Subject(s)
Electrocardiography/methods , Fetal Monitoring/methods , Heart Rate, Fetal , Pregnancy, Twin , Adult , Electrodes , Feasibility Studies , Female , Humans , Netherlands , Pregnancy , Prenatal Care/methods , Signal Processing, Computer-Assisted
4.
Acta Obstet Gynecol Scand ; 99(10): 1387-1395, 2020 10.
Article in English | MEDLINE | ID: mdl-32306380

ABSTRACT

INTRODUCTION: Doppler ultrasound cardiotocography is a non-invasive alternative that, despite its poor specificity, is often first choice for intrapartum monitoring. Doppler ultrasound suffers from signal loss due to fetal movements and is negatively correlated with maternal body mass index (BMI). Reported accuracy of fetal heart rate monitoring by Doppler ultrasound varies between 10.6 and 14.3 bpm and reliability between 62.4% and 73%. The fetal scalp electrode (FSE) is considered the reference standard for fetal monitoring but can only be applied after membranes have ruptured with sufficient cervical dilatation and is sometimes contra-indicated. A non-invasive alternative that overcomes the shortcomings of Doppler ultrasound, providing reliable information on fetal heart rate, could be the answer. Non-invasive fetal electrocardiography (NI-fECG) uses a wireless electrode patch on the maternal abdomen to obtain both fetal and maternal heart rate signals as well as an electrohysterogram. We aimed to validate a wireless NI-fECG device for intrapartum monitoring in term singleton pregnancies, by comparison with the FSE. MATERIAL AND METHODS: We performed a multicenter cross-sectional observational study at labor wards of 6 hospitals located in the Netherlands, Belgium, and Spain. Laboring women with a healthy singleton fetus in cephalic presentation and gestational age between 36 and 42 weeks were included. Participants received an abdominal electrode patch and FSE after written informed consent. Accuracy, reliability, and success rate of fetal heart rate readings were determined, using FSE as reference standard. Analysis was performed for the total population and measurement period as well as separated by labor stage and BMI class (≤30 and >30 kg/m2 ). RESULTS: We included a total of 125 women. Simultaneous registrations with NI-fECG and FSE were available in 103 women. Overall accuracy is -1.46 bpm and overall reliability 86.84%. Overall success rate of the NI-fECG is around 90% for the total population as well as for both BMI subgroups. Success rate dropped to 63% during second stage of labor, similar results are found when looking at the separate BMI groups. CONCLUSIONS: Performance measures of the NI-fECG device are good in the overall group and the separate BMI groups. Compared with Doppler ultrasound performance measures from the literature, NI-fECG is a more accurate alternative. Especially, when women have a higher BMI, NI-fECG performs well, resembling FSE performance measures.


Subject(s)
Cardiotocography/instrumentation , Heart Rate, Fetal , Wireless Technology , Adult , Body Mass Index , Cardiotocography/methods , Cross-Sectional Studies , Electrodes , Female , Humans , Pregnancy , Prospective Studies , Reproducibility of Results
5.
JMIR Ment Health ; 6(12): e15872, 2019 Dec 18.
Article in English | MEDLINE | ID: mdl-31850850

ABSTRACT

BACKGROUND: Anxiety levels before cesarean delivery (CD) can lead to a negative birth experience, which may influence several aspects of the woman's life in the long term. Improving preoperative information may lower preoperative anxiety and lead to a more positive birth experience. OBJECTIVE: This study aimed to determine whether a virtual reality (VR) video in addition to standard preoperative information decreases anxiety levels before a planned CD. METHODS: Women scheduled to undergo term elective CD were recruited from the outpatient clinic. They were randomized and stratified based on history of emergency CD (yes or no). All participants received standard preoperative information (folder leaflets and counseling by the obstetrician); the VR group additionally watched the VR video showing all aspects of CD such as the ward admission, operating theater, spinal analgesia, and moment of birth. The primary outcome measure was a change in score on the Visual Analogue Scale for Anxiety (ΔVAS-A) measured at admission for CD, compared with the baseline VAS-A score. RESULTS: A total of 97 women were included for analysis. The baseline characteristics were similar in both groups, except for a significantly higher level of education in the control group. There was no significant decrease in the VAS-A score of the women in the VR group (n=49) compared with those in the control group (n=48; ΔVAS-A=1.0; P=.08; 95% CI -0.1 to 2.0). Subgroup analysis for the group of women with a history of emergency CD showed a trend toward decreased preoperative anxiety, despite the small sample size of this subgroup (n=17; P=.06). Of the 26 participants who provided completed questionnaires, 22 (85%) in the VR group reported feeling more prepared after seeing the VR video; of the 24 participants' partners who completed the questionnaires, 19 (79%) agreed with the participants. No discomfort or motion sickness was reported. CONCLUSIONS: A VR video may help patients and their partners feel better prepared when planning a CD. This study showed that VR does not lead to a decrease in preoperative anxiety. However, subgroups such as women with a history of emergency CD may benefit from VR videos. TRIAL REGISTRATION: International Standard Randomised Controlled Trial Number (ISRCTN) 74794447; http://www.isrctn.com/ISRCTN74794447 (retrospectively registered).

6.
Ned Tijdschr Geneeskd ; 1632019 09 09.
Article in Dutch | MEDLINE | ID: mdl-31556492

ABSTRACT

Since the publication of the results of the Term Breech Trial (TBT) in 2000 the number of planned Caesarean sections for breech presentation has increased dramatically, at the expense of vaginal breech deliveries. The favourable effect of a planned Caesarean section for breech presentation on perinatal outcomes described in the TBT could not, however, be reproduced in later trials. A planned Caesarean section does carry an increased risk of maternal complications; furthermore, a previous Caesarean section leads to higher risks for both mother and child in any subsequent pregnancy. A recent prospective study advocates vaginal breech delivery 'on all fours', a position in which the mother leans on her hands and knees during delivery. A vaginal breech delivery in this position seems to be just as safe for the child as a planned Caesarean section, while a vaginal delivery is safer for the mother than a Caesarean section. This article describes two uncomplicated vaginal breech deliveries in the all fours position.


Subject(s)
Breech Presentation/therapy , Delivery, Obstetric/methods , Labor, Obstetric , Patient Positioning/methods , Adult , Cesarean Section/adverse effects , Female , Humans , Infant, Newborn , Pregnancy , Pregnancy Outcome , Prospective Studies
7.
BMJ Case Rep ; 12(7)2019 Jul 01.
Article in English | MEDLINE | ID: mdl-31266761

ABSTRACT

A non-invasive fetal ECG was performed on a 36-year-old pregnant woman at 24+6 weeks of gestation as part of ongoing clinical research. A paediatric cardiologist suspected an incomplete bundle branch block based on the averaged ECGs from the recording. The characteristic terminal R' wave was present in multiple leads of the fetal ECGs. A fetal anomaly scan had been performed at 20 weeks of gestation and showed no abnormalities. An incomplete right bundle branch block was confirmed on an ECG recorded at the age of 2 years. This case shows the possibility of novel non-invasive fetal ECG technology as an adjunct to the diagnosis of fetal cardiac anomalies in the future.


Subject(s)
Bundle-Branch Block/diagnosis , Electrocardiography/methods , Prenatal Diagnosis/methods , Adult , Bundle-Branch Block/physiopathology , Diagnosis, Differential , Female , Humans , Infant, Newborn , Male , Pregnancy
SELECTION OF CITATIONS
SEARCH DETAIL
...