Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 15(11): e0242856, 2020.
Article in English | MEDLINE | ID: mdl-33237968

ABSTRACT

Autonomic nervous function evaluated by heart rate variability (HRV) and blood characteristics were compared between Holstein Friesian cows that developed postpartum fever (PF; n = 5) and clinically healthy (CH; n = 6) puerperal cows in this case-control study. A cow was defined as having PF when its rectal temperature rose to ≥39.5°C between 1 and 3 days postpartum. We recorded electrocardiograms during this period using a Holter-type electrocardiograph and applied power spectral analysis of HRV. Comparisons between the groups were analyzed by t test or Mann-Whitney U test, and the relationship between rectal temperature and each parameter was analyzed using multiple regression analysis. Heart rate was higher in PF cows than in CH cows (Mean ± SE, 103.3 ± 2.7 vs. 91.5 ± 1.7 bpm). This result suggested that PF cows had a relatively dominant sympathetic nervous function. Total (44,472 ± 2,301 vs. 55,373 ± 1,997 ms) and low frequency power (24.5 ± 3.8 vs. 39.9 ± 5.3 ms) were lower in PF cows than in CH cows. These findings were possibly caused by a reduction in autonomic nervous function. The total white blood cell count (54.3 ± 5.1 vs. 84.5 ± 6.4 ×102/µL) and the serum magnesium (2.1 ± 0.1 vs. 2.4 ± 0.1 mg/dL) and iron (81.5 ± 8.0 vs. 134.4 ± 9.1 µg/dL) concentrations were lower and the serum amyloid A concentration (277 ± 33 vs. 149 ± 21 µg/mL) was higher in PF cows than in CH cows. These results imply that more inflammation was present in PF cows than in CH cows. Multiple regression analysis showed that both of low frequency power and concentration of serum iron were associated with rectal temperature. We found differences in changes in hematologic results, biochemical findings, and HRV patterns between PF cows and CH cows.


Subject(s)
Fever/physiopathology , Postpartum Period/physiology , Puerperal Infection/microbiology , Animals , Case-Control Studies , Cattle , Female , Fever/genetics , Fever/microbiology , Heart Rate/genetics , Heart Rate/physiology , Humans , Lactation/physiology , Photoperiod , Postpartum Period/genetics , Pregnancy , Puerperal Infection/pathology
2.
Sensors (Basel) ; 18(2)2018 Jan 23.
Article in English | MEDLINE | ID: mdl-29360799

ABSTRACT

The purpose of this paper is to show the feasibility of grasping force control by feeding back signals of the developed micro-laser Doppler velocimeter (µ-LDV) and by discriminating whether a grasped object is slipping or not. LDV is well known as a high response surface velocity sensor which can measure various surfaces-such as metal, paper, film, and so on-thus suggesting the potential application of LDV as a slip sensor for grasping various objects. However, the use of LDV as a slip sensor has not yet been reported because the size of LDVs is too large to be installed on a robotic fingertip. We have solved the size problem and enabled the performance of a feasibility test with a few-millimeter-scale LDV referred to as micro-LDV (µ-LDV) by modifying the design which was adopted from MEMS (microelectromechanical systems) fabrication process. In this paper, by applying our developed µ-LDV as a slip sensor, we have successfully demonstrated grasping force control with three target objects-aluminum block, wood block, and white acrylic block-considering that various objects made of these materials can be found in homes and factories, without grasping force feedback. We provide proofs that LDV is a new promising candidate slip sensor for grasping force control to execute target grasping.

3.
Sensors (Basel) ; 17(4)2017 Mar 27.
Article in English | MEDLINE | ID: mdl-28346374

ABSTRACT

Monitoring rumen conditions in cows is important because a dysfunctional rumen system may cause death. Sub-acute ruminal acidosis (SARA) is a typical disease in cows, and is characterized by repeated periods of low ruminal pH. SARA is regarded as a trigger for rumen atony, rumenitis, and abomasal displacement, which may cause death. In previous studies, rumen conditions were evaluated by wireless sensor nodes with pH measurement capability. The primary advantage of the pH sensor is its ability to continuously measure ruminal pH. However, these sensor nodes have short lifetimes since they are limited by the finite volume of the internal liquid of the reference electrode. Mimicking rumen atony, we attempt to evaluate the rumen condition using wireless sensor nodes with three-axis accelerometers. The theoretical life span of such sensor nodes depends mainly on the transmission frequency of acceleration data and the size of the battery, and the proposed sensor nodes are 30.0 mm in diameter and 70.0 mm in length and have a life span of over 600 days. Using the sensor nodes, we compare the rumen motility of the force transducer measurement with the three-axis accelerometer data. As a result, we can detect discriminative movement of rumen atony.


Subject(s)
Rumen , Acidosis , Animals , Cattle , Cattle Diseases , Diet , Female , Hydrogen-Ion Concentration , Lactation
4.
Anim Reprod Sci ; 180: 50-57, 2017 May.
Article in English | MEDLINE | ID: mdl-28330768

ABSTRACT

In the present study, the ventral tail base surface temperature (ST) was monitored using a wearable wireless sensor for estrus detection in cattle. Relationships among ST, behavioral estrus expression, ovulation, and changes in hormone profiles during the estrous cycle were examined. Holstein Friesian or Japanese Black female cattle were used in summer (August-September), autumn (October-November) and winter (January-February; three animals per season). On Day 11 of the estrous cycle (Day 0=the day of ovulation), the sensor was attached to the surface of the ventral tail base and ST was measured every 2min until Day 11 of the next estrous cycle. Hourly maximum ST values were used for analysis. To exclude circadian rhythm and seasonal effects, ST changes were expressed as residual temperatures (RT=actual ST - mean ST for the same hour on the previous 3days). Obvious circadian rhythms of the ST were observed and daily changes in the ST significantly differed among seasons. There was no significant seasonal difference, however, in the RT. The mean RT increased significantly ∼24 compared with ∼48h before ovulation. The mean maximum RT was 1.27±0.30°C, which was observed 5.6±2.4h after the onset of estrus, 2.4±1.3h before LH peak, and 26.9±1.2h before ovulation. The ST of the ventral tail base could be monitored throughout the estrous cycle and could detect a substantial change around the time of expression of behavioral estrus. Calculation and analysis of the RT could be useful for automatic estrous detection.


Subject(s)
Cattle/physiology , Estrus Detection/instrumentation , Monitoring, Physiologic/veterinary , Animals , Body Temperature , Estrus/physiology , Estrus Detection/methods , Female , Monitoring, Physiologic/instrumentation , Tail
5.
Sensors (Basel) ; 15(10): 25507-19, 2015 Oct 05.
Article in English | MEDLINE | ID: mdl-26445047

ABSTRACT

Wearable wireless physiological sensors are helpful for monitoring and maintaining human health. Blood flow contains abundant physiological information but it is hard to measure blood flow during exercise using conventional blood flowmeters because of their size, weight, and use of optic fibers. To resolve these disadvantages, we previously developed a micro integrated laser Doppler blood flowmeter using microelectromechanical systems technology. This micro blood flowmeter is wearable and capable of stable measurement signals even during movement. Therefore, we attempted to measure skin blood flow at the forehead, fingertip, and earlobe of seven young men while running as a pilot experiment to extend the utility of the micro blood flowmeter. We measured blood flow in each subject at velocities of 6, 8, and 10 km/h. We succeeded in obtaining stable measurements of blood flow, with few motion artifacts, using the micro blood flowmeter, and the pulse wave signal and motion artifacts were clearly separated by conducting frequency analysis. Furthermore, the results showed that the extent of the changes in blood flow depended on the intensity of exercise as well as previous work with an ergometer. Thus, we demonstrated the capability of this wearable blood flow sensor for measurement during exercise.


Subject(s)
Laser-Doppler Flowmetry/instrumentation , Monitoring, Ambulatory/instrumentation , Regional Blood Flow/physiology , Running/physiology , Adult , Flowmeters , Hemodynamics , Humans , Laser-Doppler Flowmetry/methods , Male , Micro-Electrical-Mechanical Systems , Mobile Applications , Rheology , Telemetry/instrumentation , Young Adult
6.
Circ J ; 79(4): 794-801, 2015.
Article in English | MEDLINE | ID: mdl-25740056

ABSTRACT

BACKGROUND: Because the conventional evaluation of autonomic nervous system (ANS) function inevitably uses long-lasting uncomfortable electrocardiogram (ECG) recording, a more simplified and comfortable analysis system has been sought for this purpose. The feasibility of using a portable micro-electromechanical system (MEMS) blood flowmeter to analyze heart rate variability (HRV) for evaluating ANS function was thus examined. METHODS AND RESULTS: Measurements of the R-R interval (TRR) derived from an ECG, simultaneously with the pulse wave interval (TPP) derived from a MEMS blood flowmeter, in 8 healthy subjects was performed and resultant HRV variables in time and frequency domains were compared. The TRR- and TPP-derived variables were strongly correlated (coefficients of regression for low frequency (LF), high frequency (HF), and LF/HF of 1.1, 0.66, and 0.35, respectively; corresponding coefficients of determination of 0.92, 0.63, and 0.91, respectively (P<0.01)). In addition, the values of LF, HF, and LF/HF, as analyzed using TPP, changed significantly from the supine to the standing position in another 6 subjects. CONCLUSIONS: Miniaturized-MEMS blood flowmetry can be used to perform HRV analysis for the evaluation of ANS function, which is as accurate as analysis based on ECG within comparable tolerances. As MEMS blood flowmetry can more easily and comfortably record physiological variables for longer durations than ECG recording, and can further capture skin blood flow information, this device has great potential to be used in a wider area of physiological analyses.


Subject(s)
Electrocardiography , Heart Rate/physiology , Hemorheology/physiology , Adult , Female , Humans , Male
7.
Proc Inst Mech Eng H ; 226(10): 759-65, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23157077

ABSTRACT

Alcohol has a variety of effects on the human body, affecting both the sympathetic and parasympathetic nervous system. We examined the peripheral blood flow of alcohol drinkers using a micro-integrated laser Doppler blood flow meter (micro-electromechanical system blood flow sensor). An increased heart rate and blood flow was recorded at the earlobe after alcohol ingestion, and we observed strong correlation between blood flow, heart rate, and breath alcohol content in light drinkers; but not heavy drinkers. We also found that the amplitude of pulse waves measured at the fingertip during an arm-raising test significantly decreased on alcohol consumption, regardless of the individual's alcohol tolerance. Our micro-electromechanical system blood flow sensor successfully detected various physiological changes in peripheral blood circulation induced by alcohol consumption.


Subject(s)
Blood Flow Velocity/physiology , Blood Pressure/physiology , Ethanol/administration & dosage , Heart Rate/physiology , Laser-Doppler Flowmetry/instrumentation , Movement/physiology , Administration, Oral , Adult , Arm/physiology , Blood Flow Velocity/drug effects , Blood Pressure/drug effects , Equipment Design , Female , Heart Rate/drug effects , Humans , Male , Miniaturization , Movement/drug effects , Systems Integration , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...