Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Orthop Relat Res ; 478(1): 142-143, 2020 01.
Article in English | MEDLINE | ID: mdl-31764313

Subject(s)
Ulna , Adult , Humans
3.
Am J Orthop (Belle Mead NJ) ; 44(9): E326-30, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26372759

ABSTRACT

Computed tomography (CT) is often used to evaluate intra-articular distal humerus fracture patterns, but it increases radiation exposure and cost. We conducted a study to determine the effect of adding CT evaluation to plain radiographic evaluation on the classification of, and treatment plans for, intra-articular distal humerus fractures. Nine blinded orthopedic surgeons evaluated 30 consecutive fractures for classification and surgical approach. Evaluations were performed first using plain radiographs and then again using the same radiographs plus CT images. Statistical analysis was performed using the κ correlation coefficient and Cramer V testing. We hypothesized that adding CT images to plain radiographs would change the classification and treatment of these fractures and would improve interobserver agreement on classification and treatment. Intraobserver reliability (Cramer V) was fair (.393) for classification and moderate (.426) for treatment. Interobserver reliability (Cohen κ) did not improve with CT: For classification, κ was .21 without CT and .20 with CT; for treatment, κ was .28 without CT and .27 with CT. When classifying the fractures, attending surgeons chose the multiplanar fracture pattern 25.6% of the time without CT, and remained consistent at 23.3% with CT. Trainees chose this fracture pattern much less often without CT than with CT. Use of CT changed the treatment for multiplanar fractures (73.7% lateral approach vs 51.9% posterior approach with olecranon osteotomy). When added to plain radiographic evaluation, CT evaluation changes classification and treatment plans. Interobserver reliability did not improve. Less experienced surgeons were more likely to identify multiplanar fracture patterns with use of CT. We recommend performing CT for all intra-articular distal humerus fractures.


Subject(s)
Fractures, Bone/diagnostic imaging , Humerus/diagnostic imaging , Intra-Articular Fractures/diagnostic imaging , Humans , Humerus/injuries , Observer Variation , Reproducibility of Results , Tomography, X-Ray Computed/methods
4.
J Shoulder Elbow Surg ; 24(12): 1915-25, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26212759

ABSTRACT

BACKGROUND: The purpose of this study was to explore relationships between damage modes in explanted reverse total shoulder arthroplasty (RTSA) components, patient and radiographic risk factors, and functional data to elucidate trends in RTSA failure. METHODS: Fifty RTSA systems, retrieved from 44 patients, with 50 polyethylene (PE) liners, 30 glenospheres, 21 glenoid baseplates, 13 modular humeral metaphases, and 17 humeral stems, were examined for damage modes, including abrasion, burnishing, dishing, embedding, scratching, and pitting. PE liners were also analyzed for delamination and edge deformation. Charts were reviewed for patient, surgical, and functional data. Pre-revision radiographs were analyzed for scapular notching and loosening. RESULTS: Average term of implantation was 20 months (range, 0-81 months). Metallic components exhibited abrasion, burnishing, dishing, pitting, and scratching. PE liners displayed all damage modes. Damage was exhibited on 93% of glenospheres and 100% of PE liners. Of 29 aseptic shoulders, 13 showed evidence of scapular notching and 5 of humeral loosening. There was a moderate correlation between radiographically observed implant failure or dissociation and PE embedding (r = 0.496; P < .001). There were weak and moderate correlations between scapular notching severity and PE dishing (r = 0.496; P = .006), embedding (r = 0.468; P = .010), and delamination (r = 0.384; P = .040). CONCLUSIONS: To date, this is the largest series of retrieved RTSA components and the first to relate damage modes to radiographic and clinical data. Most damage was observed on the PE liners, on both the articular surface and rim, and glenosphere components. Correlation of retrieval findings with radiographic and clinical data may help establish predictors of prostheses at risk for failure.


Subject(s)
Arthroplasty, Replacement/adverse effects , Joint Diseases/surgery , Joint Prosthesis , Range of Motion, Articular/physiology , Shoulder Joint , Aged , Aged, 80 and over , Female , Humans , Joint Diseases/diagnostic imaging , Joint Diseases/physiopathology , Male , Middle Aged , Prosthesis Design , Prosthesis Failure , Radiography , Reoperation/trends , Risk Factors , Shoulder Joint/diagnostic imaging , Shoulder Joint/physiopathology , Shoulder Joint/surgery
5.
J Orthop Surg Res ; 6: 36, 2011 Jul 18.
Article in English | MEDLINE | ID: mdl-21762540

ABSTRACT

INTRODUCTION: The clinical outcome of hemiarthroplasty for proximal humeral fractures is not satisfactory. Secondary fragment dislocation may prevent bone integration; the primary stability by a fixation technique is therefore needed to accomplish tuberosity healing. Present technical comparison of surgical fixation techniques reveals the state-of-the-art approach and highlights promising techniques for enhanced stability. METHOD: A classification of available fixation techniques for three- and four part fractures was done. The placement of sutures and cables was described on the basis of anatomical landmarks such as the rotator cuff tendon insertions, the bicipital groove and the surgical neck. Groups with similar properties were categorized. RESULTS: Materials used for fragment fixation include heavy braided sutures and/or metallic cables, which are passed through drilling holes in the bone fragments. The classification resulted in four distinct groups: A: both tuberosities and shaft are fixed together by one suture, B: single tuberosities are independently connected to the shaft and among each other, C: metallic cables are used in addition to the sutures and D: the fragments are connected by short stitches, close to the fragment borderlines. CONCLUSIONS: A plurality of techniques for the reconstruction of a fractured proximal humerus is found. The categorisation into similar strategies provides a broad overview of present techniques and supports a further development of optimized techniques. Prospective studies are necessary to correlate the technique with the clinical outcome.


Subject(s)
Arthroplasty/methods , Fracture Fixation/methods , Shoulder Fractures/surgery , Aged , Arthroplasty/instrumentation , Bone Wires , Fracture Fixation/instrumentation , Humans , Middle Aged , Prostheses and Implants , Prosthesis Design , Sutures
6.
J Shoulder Elbow Surg ; 20(8): 1241-7, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21420325

ABSTRACT

BACKGROUND: The Polaris nail is an intramedullary device for treating displaced proximal humerus fractures with few published studies to support its use. Results of a consecutive series of patients treated with the Polaris nail are presented. METHODS: Eighteen patients with a mean age of 71 years (range, 37-84) were treated for twelve 2- and six 3-part fractures. Radiographic results for all patients were evaluated. Thirteen patients with an average follow-up of 42 months (range, 24-84) were available for functional evaluation. RESULTS: Seventeen of 18 patients healed. Postoperatively, the neck/shaft angle collapsed an average 11° (range, 5-30°) into varus. Nine of 18 patients had final neck/shaft angles <120° and were considered radiographic malunions. The mean Constant and American Shoulder and Elbow Surgeons (ASES) scores were 61 (range, 20-100) and 67 (range, 10-100), respectively. Forward elevation averaged 118°. Patients had an average 5/8 positive rotator cuff signs. Seven patients underwent reoperation for loss of fixation or prominent hardware, and 1 required revision to a hemiarthroplasty. CONCLUSION: This study shows a higher than reported percentage of unsatisfactory results using the Polaris nail. The device violates the rotator cuff and is unable to resist the deforming forces that can lead to loss of fixation and varus collapse.


Subject(s)
Bone Nails , Fracture Fixation, Intramedullary/instrumentation , Fractures, Malunited/surgery , Shoulder Fractures/surgery , Shoulder Joint/surgery , Adult , Aged , Aged, 80 and over , Female , Follow-Up Studies , Fracture Healing , Fractures, Malunited/diagnostic imaging , Fractures, Malunited/physiopathology , Humans , Male , Middle Aged , Prosthesis Design , Radiography , Range of Motion, Articular , Retrospective Studies , Shoulder Fractures/diagnostic imaging , Shoulder Fractures/physiopathology , Shoulder Injuries , Shoulder Joint/physiopathology , Treatment Outcome
7.
Clin Orthop Relat Res ; 469(9): 2476-82, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21116759

ABSTRACT

BACKGROUND: Early failure due to glenoid loosening with anatomic total shoulder arthroplasty in patients with severe rotator cuff deficiency led to the development of the reverse ball-and-socket shoulder prosthesis. The literature reports improved short-term pain and function scores following modern reverse total shoulder arthroplasty (RTSA) in patients with cuff tear arthropathy (CTA). QUESTIONS/PURPOSES: We therefore sought to confirm previously reported short-term improvements in pain, function scores, and range of motion, in patients treated with RTSA for CTA and to identify clinical complications and radiographic notching. METHODS: We retrospectively reviewed 67 patients who underwent 71 primary RTSAs for CTA. The average age was 74 years (range, 54-92 years). All were preoperatively and postoperatively assessed using Constant-Murley and American Shoulder and Elbow Society (ASES) scores. We identified complications and examined radiographs for notching. The minimum followup was 12 months (average, 24 months; range, 12-58 months). RESULTS: Average Constant-Murley scores improved from 28 preoperatively to 62 postoperatively. Average ASES scores improved from 26 to 76. Subjective Shoulder Value (SSV) improved from 23 to 77. Active forward flexion improved from 61° preoperatively (range, 0°-137°) to 121° postoperatively (range, 52°-170°). Active external rotation was not affected. Thirty-five of the 71 shoulders (49%) showed radiographic notching. The overall complication rate was 23%. No patient required reoperation. One patient required closed reduction of a perioperative dislocation. CONCLUSIONS: RTSA for CTA results in functional improvement, with a low complication rate. However, the longevity of the device is currently unknown. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.


Subject(s)
Arthroplasty, Replacement , Rotator Cuff/surgery , Shoulder Joint/surgery , Tendon Injuries/surgery , Aged , Aged, 80 and over , Arthroplasty, Replacement/adverse effects , Arthroplasty, Replacement/instrumentation , Biomechanical Phenomena , Disability Evaluation , Female , Humans , Joint Prosthesis , Male , Michigan , Middle Aged , Muscle Strength , Pain Measurement , Pain, Postoperative/etiology , Pain, Postoperative/prevention & control , Prosthesis Design , Radiography , Range of Motion, Articular , Recovery of Function , Reoperation , Retrospective Studies , Rotator Cuff/diagnostic imaging , Rotator Cuff/physiopathology , Rotator Cuff Injuries , Rupture , Shoulder Joint/diagnostic imaging , Shoulder Joint/physiopathology , Shoulder Pain/etiology , Shoulder Pain/prevention & control , Tendon Injuries/diagnostic imaging , Tendon Injuries/physiopathology , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...