1.
Anal Sci ; 31(8): 781-5, 2015.
Article in English | MEDLINE | ID: mdl-26256601

ABSTRACT

With a view to enhance the sensitivity of analytical instruments used in the measurement of trace elements contained in a single cell, we have now equipped the previously reported micro-droplet injection system (M-DIS) with a desolvation system. This modified M-DIS was coupled to inductively coupled plasma atomic emission spectroscopy (ICP-AES) and evaluated for its ability to measure trace elements. A flow rate of 100 mL/min for the additional gas and a measurement point -7.5 mm above the load coil (ALC) have been determined to be the optimal parameters for recording the emission intensity of the Ca(II) spectral lines. To evaluate the influence of the desolvation system, we recorded the emission intensities of the Ca(I), Ca(II), and H-ß spectral lines with and without inclusion of the desolvation system. The emission intensity of the H-ß spectral line reduces and the magnitude of the Ca(II)/Ca(I) emission intensity ratio increases four-fold with inclusion of the desolvation system. Finally, the elements Ca, Mg, and Fe present in a single cell of Pseudococcomyxa simplex are simultaneously determined by coupling the M-DIS equipped with the desolvation system to ICP-AES.


Subject(s)
Plasma Gases/chemistry , Single-Cell Analysis/methods , Spectrophotometry, Atomic/methods , Trace Elements/analysis , Analytic Sample Preparation Methods , Chlorophyta/cytology , Solvents/chemistry
2.
Anal Sci ; 29(12): 1147-51, 2013.
Article in English | MEDLINE | ID: mdl-24334979

ABSTRACT

We developed an injection gas heating system for introducing large droplets, because we want to effectively to measure elements in a single cell. This system was applied to ICP-atomic emission spectrometry (ICP-AES), to evaluate it performance. To evaluate the effect of the emission intensity, the emission intensity of Ca(II) increased to a maximum of tenfold at 147°C and the peak was shifted upstream of the plasma. To investigate in detail the effect of an injection gas heating system, we studied different conditions of the injection gas temperature and droplet volume. When the injection gas temperature was 89°C, smaller droplets were easily ionized. At 147°C, the emission intensity ratio and the absolute amount of the sample including the droplet exhibited close agreement. These results show the advantages of the injection gas heating system for large droplet introduction, and the sufficient reduction in the solvent load. The solvent load could be reduced by heating to 147°C using the system.

SELECTION OF CITATIONS
SEARCH DETAIL
...