Pharmaceuticals (Basel) ; 17(5)2024 May 14.
Article in English | MEDLINE | ID: mdl-38794199

ABSTRACT

Radiotherapy treatment plans have become highly conformal, posing additional constraints on the accuracy of treatment delivery. Here, we explore the use of radiation-sensitive ultrasound contrast agents (superheated phase-change nanodroplets) as dosimetric radiation sensors. In a series of experiments, we irradiated perfluorobutane nanodroplets dispersed in gel phantoms at various temperatures and assessed the radiation-induced nanodroplet vaporization events using offline or online ultrasound imaging. At 25 °C and 37 °C, the nanodroplet response was only present at higher photon energies (≥10 MV) and limited to <2 vaporization events per cm2 per Gy. A strong response (~2000 vaporizations per cm2 per Gy) was observed at 65 °C, suggesting radiation-induced nucleation of the droplet core at a sufficiently high degree of superheat. These results emphasize the need for alternative nanodroplet formulations, with a more volatile perfluorocarbon core, to enable in vivo photon dosimetry. The current nanodroplet formulation carries potential as an innovative gel dosimeter if an appropriate gel matrix can be found to ensure reproducibility. Eventually, the proposed technology might unlock unprecedented temporal and spatial resolution in image-based dosimetry, thanks to the combination of high-frame-rate ultrasound imaging and the detection of individual vaporization events, thereby addressing some of the burning challenges of new radiotherapy innovations.

2.
Ultrasound Med Biol ; 48(11): 2207-2216, 2022 11.
Article in English | MEDLINE | ID: mdl-35963827

ABSTRACT

Shear wave elastography (SWE) is a promising technique used to assess cardiac function through the evaluation of cardiac stiffness non-invasively. However, in the literature, SWE varies in terms of tissue motion data (displacement, velocity or acceleration); method used to characterize mechanical wave propagation (time domain [TD] vs. frequency domain [FD]); and the metric reported (wave speed [WS], shear or Young's modulus). This variety of reported methodologies complicates comparison of reported findings and sheds doubt on which methodology better approximates the true myocardial properties. We therefore conducted a simulation study to investigate the accuracy of various SWE data analysis approaches while varying cardiac geometry and stiffness. Lower WS values were obtained by the TD method compared with the FD method. Acceleration-based WS estimates in the TD were systematically larger than those based on velocity (∼10% difference). These observations were confirmed by TD analysis of 32 in vivo SWE mechanical wave measurements. In vivo data quality is typically too low for accurate FD analysis. Therefore, our study suggests using acceleration-based TD analysis for in vivo SWE to minimize underestimation of the true WS and, thus, to maximize the sensitivity of SWE to detect stiffness changes resulting from pathology.


Subject(s)
Elasticity Imaging Techniques , Acceleration , Elastic Modulus , Elasticity Imaging Techniques/methods , Heart/diagnostic imaging , Motion
3.
Med Phys ; 48(4): 1983-1995, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33587754

ABSTRACT

PURPOSE: Despite the physical benefits of protons over conventional photon radiation in cancer treatment, range uncertainties impede the ability to harness the full potential of proton therapy. While monitoring the proton range in vivo could reduce the currently adopted safety margins, a routinely applicable range verification technique is still lacking. Recently, phase-change nanodroplets were proposed for proton range verification, demonstrating a reproducible relationship between the proton range and generated ultrasound contrast after radiation-induced vaporization at 25°C. In this study, previous findings are extended with proton irradiations at different temperatures, including the physiological temperature of 37°C, for a novel nanodroplet formulation. Moreover, the potential to modulate the linear energy transfer (LET) threshold for vaporization by varying the degree of superheat is investigated, where the aim is to demonstrate vaporization of nanodroplets directly by primary protons. METHODS: Perfluorobutane nanodroplets with a shell made of polyvinyl alcohol (PVA-PFB) or 10,12-pentacosadyinoic acid (PCDA-PFB) were dispersed in polyacrylamide hydrogels and irradiated with 62 MeV passively scattered protons at temperatures of 37°C and 50°C. Nanodroplet transition into echogenic microbubbles was assessed using ultrasound imaging (gray value and attenuation analysis) and optical images. The proton range was measured independently and compared to the generated contrast. RESULTS: Nanodroplet design proved crucial to ensure thermal stability, as PVA-shelled nanodroplets dramatically outperformed their PCDA-shelled counterpart. At body temperature, a uniform radiation response proximal to the Bragg peak is attributed to nuclear reaction products interacting with PVA-PFB nanodroplets, with the 50% drop in ultrasound contrast being 0.17 mm ± 0.20 mm (mean ± standard deviation) in front of the proton range. Also at 50°C, highly reproducible ultrasound contrast profiles were obtained with shifts of -0.74 mm ± 0.09 mm (gray value analysis), -0.86 mm ± 0.04 mm (attenuation analysis) and -0.64 mm ± 0.29 mm (optical analysis). Moreover, a strong contrast enhancement was observed near the Bragg peak, suggesting that nanodroplets were sensitive to primary protons. CONCLUSIONS: By varying the degree of superheat of the nanodroplets' core, one can modulate the intensity of the generated ultrasound contrast. Moreover, a submillimeter reproducible relationship between the ultrasound contrast and the proton range was obtained, either indirectly via the visualization of secondary reaction products or directly through the detection of primary protons, depending on the degree of superheat. The potential of PVA-PFB nanodroplets for in vivo proton range verification was confirmed by observing a reproducible radiation response at physiological temperature, and further studies aim to assess the nanodroplets' performance in a physiological environment. Ultimately, cost-effective online or offline ultrasound imaging of radiation-induced nanodroplet vaporization could facilitate the reduction of safety margins in treatment planning and enable adaptive proton therapy.


Subject(s)
Proton Therapy , Protons , Contrast Media , Microbubbles , Ultrasonography
4.
Phys Med Biol ; 65(6): 065013, 2020 03 23.
Article in English | MEDLINE | ID: mdl-32045902

ABSTRACT

Technologies enabling in vivo range verification during proton therapy are actively sought as a means to reduce the clinical safety margins currently adopted to avoid tumor underdosage. In this contribution, we applied the semi-empirical theory of radiation-induced vaporization of superheated liquids to coated nanodroplets. Nanodroplets are injectable phase-change contrast agents that can vaporize into highly echogenic microbubbles to provide contrast in ultrasound images. We exposed nanodroplet dispersions in aqueous phantoms to monoenergetic proton beams of varying energies and doses. Ultrasound imaging of the phantoms revealed that radiation-induced droplet vaporization occurred in regions proximal to the proton Bragg peak. A statistically significant increase in contrast was observed in irradiated regions for doses as low as 2 Gy and found to be proportional to the proton fluence. The absence of enhanced response in the vicinity of the Bragg peak, combined with theoretical considerations, suggest that droplet vaporization is induced by high linear energy transfer (LET) recoil ions produced by nuclear reactions with incoming protons. Vaporization profiles were compared to non-elastic cross sections and LET characteristics of oxygen recoils. Shifts between the ultrasound image contrast drop and the expected proton range showed a sub-millimeter reproducibility. These early findings confirm the potential of superheated nanodroplets as a novel tool for proton range verification.


Subject(s)
Nanotechnology , Proton Therapy , Radiotherapy, Image-Guided/methods , Feasibility Studies , Humans , Linear Energy Transfer , Monte Carlo Method , Phantoms, Imaging , Reproducibility of Results , Ultrasonography