Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Ginekol Pol ; 67(8): 411-3, 1996 Aug.
Article in Polish | MEDLINE | ID: mdl-9139011

ABSTRACT

Measuring the level of progesterone in 80 women who according to the ultrasound images had fibrocystic mastopathy. I've concluded by comparing the ultrasound images with the measurement of hormones that there was conformity of 75%.


Subject(s)
Fibrocystic Breast Disease/blood , Fibrocystic Breast Disease/diagnostic imaging , Progesterone/blood , Adult , Female , Humans , Middle Aged , Ultrasonography
2.
Wiad Lek ; 47(13-14): 503-5, 1994 Jul.
Article in Polish | MEDLINE | ID: mdl-7716935

ABSTRACT

An attempt was undertaken at evaluation of the influence of CO2 insufflation in patients subjected to laparoscopic cholecystectomy on pulmonary dynamic compliance, pulmonary resistance, pressures in the airways, CO2 pressure in expired air, and arterialized blood gas analysis. The studies were carried out in a group of 33 patients, including 26 women and 7 men, evaluated according to ASA scale as I/II degrees. The means of the values obtained before CO2 insufflation into the peritoneal cavity were compared with the means from the period of pneumoperitoneum maintenance. Statistically significant decrease of pulmonary compliance, increase of the mean pressure in the airways and increase of CO2 pressure both in expired air and arterialized blood were demonstrated. Pulmonary resistance and oxygen pressure in blood remained without statistically significant changes. The attention was paid to the rationale of including capnometry to the standard monitoring equipment during laparoscopic operations.


Subject(s)
Carbon Dioxide/pharmacology , Cholecystectomy, Laparoscopic , Insufflation , Respiratory Mechanics/drug effects , Adult , Carbon Dioxide/blood , Female , Humans , Male , Respiratory Function Tests
3.
Ginekol Pol ; 63(2): 82-3, 1992 Feb.
Article in Polish | MEDLINE | ID: mdl-1305591

ABSTRACT

Mammography and sonography were done in 479 women. In mammography cysts were suspected in 10 cases, in 20 cases solid lumps and in 49 cases no changes were detected. In sonography in 7 cases cysts were found in 23 solid lumps, in 49 no changes were detected. It was proved that sonography is much more accurate in detecting cysts than mammography.


Subject(s)
Fibrocystic Breast Disease/diagnostic imaging , Adult , Female , Humans , Radiography , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...