Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Microbiol ; 57(11)2019 11.
Article in English | MEDLINE | ID: mdl-31434724

ABSTRACT

Laboratory tests for Clostridioides difficile infection (CDI) rely on the detection of free toxin or molecular detection of toxin genes. The Singulex Clarity C. diff toxins A/B assay is a rapid, automated, and ultrasensitive assay that detects C. difficile toxins A and B in stool. We compared CDI assays across two prospective multicenter studies to set a cutoff for the Clarity assay and to independently validate the performance compared with that of a cell culture cytotoxicity neutralization assay (CCCNA). The cutoff was set by two sites testing fresh samples from 897 subjects with suspected CDI and then validated at four sites testing fresh samples from 1,005 subjects with suspected CDI. CCCNA testing was performed at a centralized laboratory. Samples with discrepant results between the Clarity assay and CCCNA were retested with CCCNA when the Clarity result agreed with that of at least one comparator method; toxin enzyme immunoassays (EIA), glutamate dehydrogenase (GDH) detection, and PCR were performed on all samples. The cutoff for the Clarity assay was set at 12.0 pg/ml. Compared to results with CCCNA, the Clarity assay initially had 85.2% positive agreement and 92.4% negative agreement. However, when samples with discrepant results between the Clarity assay and CCCNA in the validation study were retested by CCCNA, 13/17 (76.5%) Clarity-negative but CCCNA-positive samples (Clarity+/CCCNA-) became CCCNA-, and 5/26 (19.2%) Clarity+/CCCNA- samples became CCCNA+, resulting in a 96.3% positive agreement and 93.0% negative agreement between Clarity and CCCNA results. The toxin EIA had 59.8% positive agreement with CCCNA. The Clarity assay was the most sensitive free-toxin immunoassay, capable of providing CDI diagnosis in a single-step solution. A different CCCNA result was reported for 42% of retested samples, increasing the positive agreement between Clarity and CCCNA from 85.2% to 96.3% and indicating the challenges of comparing free-toxin results to CCCNA results as a reference standard.


Subject(s)
Clostridium Infections/diagnosis , Enterotoxins/isolation & purification , Feces/chemistry , Single Molecule Imaging/methods , Adolescent , Adult , Aged , Bacteriological Techniques , Child , Child, Preschool , Clostridioides difficile , Cytotoxicity Tests, Immunologic/methods , Female , Humans , Immunoenzyme Techniques , Male , Middle Aged , Prospective Studies , Sensitivity and Specificity , Young Adult
2.
Clin Infect Dis ; 56(6): 790-7, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23223586

ABSTRACT

BACKGROUND: Antimicrobial removal devices in blood culture media are designed to remove antibiotics from the blood culture solution, thereby facilitating bacterial growth. How well these devices function clinically has not been established. METHODS: All blood drawn for culture from adult inpatients and emergency department visitors in a level I trauma center was placed in paired BACTEC Plus and BacT/Alert FAN culture media and studied simultaneously, consecutively, and prospectively between 1 February and 30 September 2011. All cultures were processed per standard laboratory protocols. RESULTS: Of 9395 total cultures collected, 1219 (13%) were positive, 831 were included, and 524 (33%) contained pathogens. BACTEC had a 4.5-hour faster detection time (P < .0001), and isolated exclusively 182 of 524 (35%; P < .001) pathogens, 136 of 345 (39%) of the gram-positive cocci (P < .001), 48 of 175 (27%; P = .02) of the gram-negative rods, 101 of 195 (52%) of Staphylococcus aureus (P < .001), and 59 of 120 (49%; P = .004) septic events. If active antibiotics had been dosed 0-4 or 4-48 hours prior to culture collection, the odds of that culture growing in BACTEC were 4.8- and 5.2-fold greater, respectively, than of growing in BacT/Alert (P < .0001). Both were equivalent in the recovery of yeast and when no antimicrobials were dosed. CONCLUSIONS: BACTEC media has faster time to detection and increased bacterial recovery over the BacT/Alert media in the following categories: overall growth, pathogens, septic events, gram-positive cocci, gram-negative rods, Staphylococcus aureus, and cultures where antimicrobials were dosed up to 48 hours before culture collection.


Subject(s)
Anti-Bacterial Agents/antagonists & inhibitors , Anti-Bacterial Agents/therapeutic use , Bacteremia/diagnosis , Bacteria/isolation & purification , Bacteriological Techniques/methods , Culture Media/chemistry , Adult , Humans , Sensitivity and Specificity , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...