Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Biomed Phys Eng Express ; 8(5)2022 07 19.
Article in English | MEDLINE | ID: mdl-35797069

ABSTRACT

Shear wave elastography (SWE) is a promising technique for characterizing carotid plaques and assessing local arterial stiffness. The mechanical stress to which the tissue is subjected during SWE using acoustic radiation force (ARF), leading to strain at a certain strain rate, is still relatively unknown. Because SWE is increasingly used for arterial applications where the mechanical stress could potentially lead to significant consequences, it is important to understand the risks of SWE-induced strain and strain rate. The aim of this study was to investigate the safety of SWE in terms of induced arterial strain and strain rateex-vivoand in a human carotid arteryin-vivo. SWE was performed on six porcine aortae as a model of the human carotid artery using different combinations of ARF push parameters (push voltage: 60/90 V, aperture width: f/1.0/1.5, push length: 100/150/200µs) and distance to push position. The largest induced strain and strain rate were 1.46% and 54 s-1(90 V, f/1.0, 200µs), respectively. Moreover, the SWE-induced strains and strain rates increased with increasing push voltage, aperture, push length, and decreasing distance between the region of interest and the push. In the human carotid artery, the SWE-induced maximum strain was 0.06% and the maximum strain rate was 1.58 s-1, compared with the maximum absolute strain and strain rate of 12.61% and 5.12 s-1, respectively, induced by blood pressure variations in the cardiac cycle. Our results indicate thatex-vivoarterial SWE does not expose the artery to higher strain rate than normal blood pressure variations, and to strain one order of magnitude higher than normal blood pressure variations, at the push settings and distances from the region of interest used in this study.


Subject(s)
Elasticity Imaging Techniques , Animals , Aorta/diagnostic imaging , Elasticity Imaging Techniques/methods , Heart , Humans , Stress, Mechanical , Swine
2.
J Med Imaging (Bellingham) ; 5(1): 014001, 2018 Jan.
Article in English | MEDLINE | ID: mdl-29322069

ABSTRACT

Treatment decision for coronary artery disease (CAD) is based on both morphological and functional information. Image fusion of coronary computed tomography angiography (CCTA) and three-dimensional echocardiography (3DE) could combine morphology and function into a single image to facilitate diagnosis. Three semiautomatic feature-based methods for CCTA/3DE registration were implemented and applied on CAD patients. Methods were verified and compared using landmarks manually identified by a cardiologist. All methods were found feasible for CCTA/3DE fusion.

3.
IEEE Trans Med Imaging ; 36(11): 2261-2275, 2017 11.
Article in English | MEDLINE | ID: mdl-28742031

ABSTRACT

The combination of medical imaging with computational fluid dynamics (CFD) has enabled the study of 3-D blood flow on a patient-specific level. However, with models based on gated high-resolution data, the study of transient flows, and any model implementation into routine cardiac care, is challenging. This paper presents a novel pathway for patient-specific CFD modelling of the left ventricle (LV), using 4-D transthoracic echocardiography (TTE) as input modality. To evaluate the clinical usability, two sub-studies were performed. First, a robustness evaluation was performed, where repeated models with alternating input variables were generated for six subjects and changes in simulated output quantified. Second, a validation study was carried out, where the pathway accuracy was evaluated against pulsed-wave Doppler (100 subjects), and 2-D through-plane phase-contrast magnetic resonance imaging measurements over seven intraventricular planes (6 subjects). The robustness evaluation indicated a model deviation of <12%, with highest regional and temporal deviations at apical segments and at peak systole, respectively. The validation study showed an error of <11% (velocities <10 cm/s) for all subjects, with no significant regional or temporal differences observed. With the patient-specific pathway shown to provide robust output with high accuracy, and with the pathway dependent only on 4-D TTE, the method has a high potential to be used within future clinical studies on 3-D intraventricular flow patterns. To this, future model developments in the form of e.g., anatomically accurate LV valves may further enhance the clinical value of the simulations.


Subject(s)
Echocardiography/methods , Heart Ventricles/diagnostic imaging , Image Processing, Computer-Assisted/methods , Patient-Specific Modeling , Ventricular Function, Left/physiology , Adult , Aged , Algorithms , Echocardiography, Doppler, Color/methods , Humans , Magnetic Resonance Imaging, Cine/methods , Middle Aged , Reproducibility of Results , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...