Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Physiol Rep ; 4(19)2016 10.
Article in English | MEDLINE | ID: mdl-27702881

ABSTRACT

Cardiac power, the product of aortic flow and blood pressure, appears to be a fundamental cardiovascular parameter. The simplified version named cardiac power output (CPO), calculated as the product of cardiac output (CO) in L/min and mean arterial pressure (MAP) in mmHg divided by 451, has shown great ability to predict outcome in a broad spectrum of cardiac disease. Beat-by-beat evaluation of cardiac power (PWR) therefore appears to be a possibly valuable addition when monitoring circulatory unstable patients, providing parameters of overall cardiovascular function. We have developed a minimally invasive system for cardiac power measurement, and aimed in this study to compare this system to an invasive method (ttPWR). Seven male anesthetized farm pigs were included. A laptop with in-house software gathered audio from Doppler signals of aortic flow and blood pressure from the patient monitor to continuously calculate and display a minimally invasive cardiac power trace (uPWR). The time integral per cardiac cycle (uPWR-integral) represents cardiac work, and was compared to the invasive counterpart (ttPWR-integral). Signals were obtained at baseline, during mechanically manipulated preload and afterload, before and after induced global ischemic left ventricular dysfunction. We found that the uPWR-integral overestimated compared to the ttPWR-integral by about 10% (P < 0.001) in both normal hearts and during ventricular dysfunction. Bland-Altman limits of agreement were at +0.060 and -0.054 J, without increasing spread over the range. In conclusion we find that the minimally invasive system follows its invasive counterpart, and is ready for clinical research of cardiac power parameters.


Subject(s)
Blood Pressure/physiology , Cardiac Output/physiology , Counterpulsation/methods , Monitoring, Intraoperative/instrumentation , Monitoring, Intraoperative/methods , Monitoring, Physiologic/methods , Ventricular Dysfunction/physiopathology , Acute Disease , Animals , Aorta/physiology , Arterial Pressure/physiology , Echocardiography, Doppler/methods , Heart Failure/physiopathology , Hemodynamics/physiology , Humans , Male , Predictive Value of Tests , Swine , Ultrasonography, Doppler/methods , Ventricular Function, Left/physiology
2.
Physiol Rep ; 1(6): e00159, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24400160

ABSTRACT

Cardiac power (PWR) is the continuous product of flow and pressure in the proximal aorta. Our aim was to validate the PWR integral as a marker of left ventricular energy transfer to the aorta, by comparing it to stroke work (SW) under multiple different loading and contractility conditions in subjects without obstructions in the left ventricular outflow tract. Six pigs were under general anesthesia equipped with transit time flow probes on their proximal aortas and Millar micromanometer catheters in their descending aortas to measure PWR, and Leycom conductance catheters in their left ventricles to measure SW. The PWR integral was calculated as the time integral of PWR per cardiac cycle. SW was calculated as the area encompassed by the pressure-volume loop (PV loop). The relationship between the PWR integral and SW was tested during extensive mechanical and pharmacological interventions that affected the loading conditions and myocardial contractility. The PWR integral displayed a strong correlation with SW in all pigs (R (2) > 0.95, P < 0.05) under all conditions, using a linear model. Regression analysis and Bland Altman plots also demonstrated a stable relationship. A mixed linear analysis indicated that the slope of the SW-to-PWR-integral relationship was similar among all six animals, whereas loading and contractility conditions tended to affect the slope. The PWR integral followed SW and appeared to be a promising parameter for monitoring the energy transferred from the left ventricle to the aorta. This conclusion motivates further studies to determine whether the PWR integral can be evaluated using less invasive methods, such as echocardiography combined with a radial artery catheter.

SELECTION OF CITATIONS
SEARCH DETAIL
...