Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
ACS Appl Bio Mater ; 5(12): 5682-5692, 2022 12 19.
Article in English | MEDLINE | ID: mdl-36368008

ABSTRACT

Recently, decellularized plant biomaterials have been explored for their use as tissue engineered substitutes. Herein, we expanded upon the investigation of the mechanical properties of these materials to explore their elasticity as many anatomical areas of the body require biomechanical dynamism. We first constructed a device to secure the scaffold and induce a strain within the physiological range of the normal human adult lung during breathing (12-20 movements/min; 10-20% elongation). Results showed that decellularized spinach leaves can support cyclic strain for 24 h and displayed heterogeneous local strain values (7.76-15.88%) as well as a Poisson's ratio (0.12) similar to that of mammalian lungs (10.67-19.67%; 0.01), as opposed to an incompressible homogeneous standard polymer (such as PDMS (10.85-12.71%; 0.4)). Imaging and mechanical testing showed that the vegetal scaffold exhibited strain hardening but maintained its structural architecture and water retention capacity, suggesting an unaltered porosity. Interestingly, we also showed that cells seeded on the scaffold can also sense the mechanical strain as demonstrated by a nuclear reorientation perpendicular to strain direction (63.3° compared to 41.2° for nonstretched cells), a nuclear location of YAP and increased expression of YAP target genes, a high cytoplasmic calcium level, and an elevated expression level of collagen genes (COL1A1, COL3A1, COL4A1, and COL6A) with an increased collagen secretion at the protein level. Taken together, these data demonstrated that decellularized plant leaf tissues have an inherent elastic property similar to that found in the mammalian system to which cells can sense and respond.


Subject(s)
Biocompatible Materials , Spinacia oleracea , Animals , Humans , Spinacia oleracea/metabolism , Collagen/metabolism , Elasticity , Tissue Engineering , Mammals/metabolism
2.
Infect Dis Rep ; 13(4): 1061-1077, 2021 Dec 14.
Article in English | MEDLINE | ID: mdl-34940407

ABSTRACT

Since the outbreak of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic in December 2019, the spread of SARS-CoV2 infection has been escalating rapidly around the world. In order to provide more timely access to medical intervention, including diagnostic tests and medical treatment, the FDA authorized multiple test protocols for diagnostic tests from nasopharyngeal swab, saliva, urine, bronchoalveolar lavage and fecal samples. The traditional diagnostic tests for this novel coronavirus 2019 require standard processes of viral RNA isolation, reverse transcription of RNA to cDNA, then real-time quantitative PCR with the RNA templates extracted from the patient samples. Recently, many reports have demonstrated a direct detection of SARS-Co-V2 genomic material from saliva samples without any RNA isolation step. To make the rapid detection of SARS-Co-V2 infection more accessible, a point-of-care type device was developed for SARS-CoV-2 detection. Herein, we report a portable microfluidic-based integrated detection-analysis system for SARS-CoV-2 nucleic acids detection directly from saliva samples. The saliva cartridge is self-contained and capable of microfluidic evaluation of saliva, from heating, mixing with the primers to multiplex real-time quantitative polymerase chain reaction, detecting SARS-CoV-2 with different primer sets and internal control. The approach has a detection sensitivity of 1000 copies/mL of SARS-CoV-2 RNA or virus, with consistency and automation, from saliva sample-in to result-out.

3.
Methods Mol Biol ; 1906: 207-224, 2019.
Article in English | MEDLINE | ID: mdl-30488395

ABSTRACT

A fully automated rapid DNA analysis system requires integrating several operational elements performing multiple steps onto one single microfluidic platform. The functions to include on the microfluidic platform consist of substrate lysis, lysate DNA extraction, single or multiplexed PCR amplification, amplicon separation, and product readout. Here we describe a fully automated integrated system for forensic short tandem repeat (STR) analysis of reference samples, achieving buccal swab-in and DNA profile-out.


Subject(s)
DNA Fingerprinting/instrumentation , Microfluidic Analytical Techniques/instrumentation , Microsatellite Repeats , DNA Fingerprinting/methods , Electrophoresis, Capillary , Equipment Design , Forensic Genetics , Humans , Microfluidic Analytical Techniques/methods , Mouth/chemistry , Multiplex Polymerase Chain Reaction , Specimen Handling
4.
Biomed Microdevices ; 16(6): 905-14, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25106501

ABSTRACT

We report a microfluidic device and measurement method to perform real-time PCR (or qPCR) in a miniaturized configuration for on-chip implementation using reaction volumes of less than 20 µL. The qPCR bioreactor is designed as a module to be embedded in an automated sample-in/profile-out system for rapid DNA biometrics or human identification. The PCR mixture is excited with a 505 nm diode-pumped solid-state laser (DPSSL) and the fluorescence build-up is measured using optical fibers directly embedded to the sidewalls of the microfluidic qPCR bioreactor. We discuss manufacturing and operating parameters necessary to adjust the internal surface conditions and temperature profiles of the bioreactor and to optimize the yield and quality of the PCR reaction for the amplification of 62 bp hTERT intron fragments using the commercial Quantifiler® kit (Life Technologies, Carlsbad, CA) commonly accepted for genotyping analysis. We designed a microfluidic device suitable for continuously processing a specimen by efficiently mixing the reagents from the kit to a set volume of DNA template on chip. Our approach relies on a calibration curve for the specific device using control DNA. We successfully applied this method to determine the concentration of genomic DNA extracted from a buccal swab on separate microfluidic devices which are operated upstream the qPCR device and perform buccal swab lysis and buccal DNA extraction. A precise correlation between the amount determined on chip and that obtained using a commercial cycler is demonstrated.


Subject(s)
Genotyping Techniques , Lab-On-A-Chip Devices , Microfluidic Analytical Techniques , Real-Time Polymerase Chain Reaction , DNA/chemistry , DNA/genetics , DNA/isolation & purification , Female , Genotyping Techniques/instrumentation , Genotyping Techniques/methods , Humans , Lasers, Semiconductor , Male , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Mouth Mucosa , Real-Time Polymerase Chain Reaction/instrumentation , Real-Time Polymerase Chain Reaction/methods , Telomerase/genetics
5.
Analyst ; 137(23): 5510-9, 2012 Dec 07.
Article in English | MEDLINE | ID: mdl-22970426

ABSTRACT

This study reports the design, prototyping, and assay development of multiplexed polymerase chain reaction (PCR) on a plastic microfluidic device. Amplification of 17 DNA loci is carried out directly on-chip as part of a system for continuous workflow processing from sample preparation (SP) to capillary electrophoresis (CE). For enhanced performance of on-chip PCR amplification, improved control systems have been developed making use of customized Peltier assemblies, valve actuators, software, and amplification chemistry protocols. Multiple enhancements to the microfluidic chip design have been enacted to improve the reliability of sample delivery through the various on-chip modules. This work has been enabled by the encapsulation of PCR reagents into a solid phase material through an optimized Solid Phase Encapsulating Assay Mix (SPEAM) bead-based hydrogel fabrication process. SPEAM bead technology is reliably coupled with precise microfluidic metering and dispensing for efficient amplification and subsequent DNA short tandem repeat (STR) fragment analysis. This provides a means of on-chip reagent storage suitable for microfluidic automation, with the long shelf-life necessary for point-of-care (POC) or field deployable applications. This paper reports the first high quality 17-plex forensic STR amplification from a reference sample in a microfluidic chip with preloaded solid phase reagents, that is designed for integration with up and downstream processing.


Subject(s)
DNA/analysis , Microfluidic Analytical Techniques/instrumentation , Multiplex Polymerase Chain Reaction/methods , Forensic Sciences , Humans , Microsatellite Repeats , Point-of-Care Systems
6.
Electrophoresis ; 33(16): 2604-11, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22899270

ABSTRACT

We report the design and performance validation of microfluidic separation technologies for human identification using a disposable plastic device suitable for integration into an automated rapid DNA analysis system. A fabrication process for a 15-cm long hot-embossed plastic microfluidic devices with a smooth semielliptical cross section out of cyclic olefin copolymer is presented. We propose a mixed polymer solution of 95% w/v hydroxyethylcellulose and 5% w/v polyvinylpyrrolidone for a final polymer concentration of 2.5 or 3.0% to be used as coating and sieving matrix for DNA separation. This formulation allows preparing the microchip without pretreatment in a single-loading step and provides high-resolution separation (≈1.2 bp for fragments <200 bp), which is superior to existing commercial matrices under the same conditions. The hot-embossed device performance is characterized and compared to injection-molded devices made out of cyclic olefin copolymer based on their respective injector geometry, channel shape, and surface charges. Each device design is assessed by fluorescence videomicroscopy to evaluate the formation of injection plugs, then by comparing electropherograms for the separation of a DNA size standard relevant to human identification.


Subject(s)
DNA/analysis , Electrophoresis, Capillary/instrumentation , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Povidone/chemistry , DNA/isolation & purification , Electrophoresis, Capillary/methods , Equipment Design , Humans , Kinetics , Spectrometry, Fluorescence
7.
Electrophoresis ; 31(21): 3510-7, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20931618

ABSTRACT

The microfluidic integration of an entire DNA analysis workflow on a fully integrated miniaturized instrument is reported using lab-on-a-chip automation to perform DNA fingerprinting compatible with CODIS standard relevant to the forensic community. The instrument aims to improve the cost, duration, and ease of use to perform a "sample-to-profile" analysis with no need for human intervention. The present publication describes the operation of the three major components of the system: the electronic control components, the microfluidic cartridge and CE microchip, and the optical excitation/detection module. Experimental details are given to characterize the level of performance, stability, reliability, accuracy, and sensitivity of the prototype system. A typical temperature profile from a PCR amplification process and an electropherogram of a commercial size standard (GeneScan 500™, Applied Biosystems) separation are shown to assess the relevance of the instrument to forensic applications. Finally, we present a profile from an automated integrated run where lysed cells from a buccal swab were introduced in the system and no further human intervention was required to complete the analysis.


Subject(s)
Electrophoresis, Capillary/methods , Microfluidic Analytical Techniques/instrumentation , Microsatellite Repeats , Polymerase Chain Reaction/methods , Sequence Analysis, DNA/instrumentation , Cheek , DNA/chemistry , DNA/isolation & purification , Forensic Genetics/methods , Humans , Microfluidic Analytical Techniques/methods , Mouth Mucosa/cytology , Reproducibility of Results , Sequence Analysis, DNA/methods , Temperature
8.
Anal Chem ; 82(16): 6991-9, 2010 Aug 15.
Article in English | MEDLINE | ID: mdl-20704389

ABSTRACT

We demonstrate a conduit for the delivery of a step change in the DNA analysis process: A fully integrated instrument for the analysis of multiplex short tandem repeat DNA profiles from reference buccal samples is described and is suitable for the processing of such samples within a forensic environment such as a police custody suite or booking office. The instrument is loaded with a DNA processing cartridge which incorporates on-board pumps and valves which direct the delivery of sample and reagents to the various reaction chambers to allow DNA purification, amplification of the DNA by PCR, and collection of the amplified product for delivery to an integral CE chip. The fluorescently labeled product is separated using micro capillary electrophoresis with a resolution of 1.2 base pairs (bp) allowing laser induced fluorescence-based detection of the amplified short tandem repeat fragments and subsequent analysis of data to produce a DNA profile which is compatible with the data format of the UK DNA database. The entire process from taking the sample from a suspect, to database compatible DNA profile production can currently be achieved in less than 4 h. By integrating such an instrument and microfluidic cartridge with the forensic process, we believe it will be possible in the near future to process a DNA sample taken from an individual in police custody and compare the profile with the DNA profiles held on a DNA Database in as little as 3 h.


Subject(s)
DNA/analysis , Forensic Genetics/methods , Microfluidic Analytical Techniques/methods , Databases, Nucleic Acid , Polymerase Chain Reaction , Specimen Handling , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...