1.
J Anat ; 241(3): 756-764, 2022 09.
Article in English | MEDLINE | ID: mdl-35662008

ABSTRACT

The pelvic ring is a complex anatomical structure building up the connection between the trunk and the legs. Whilst there is a broad discussion in the literature about the dynamic interaction between spine, pelvis and the hip joints, there is still little information about the relation and interaction of the constant pelvic parameters. Based on a three-dimensional (3D) statistical model consisting of 150 uninjured and bony healthy pelves (100 Europeans, 50 Japanese; 81 males, 69 females; average age 74.3 years ± 17.5 years) an evaluation of pelvic incidence (PI) and acetabular orientation in anteversion and inclination was performed and potential correlations of these intraindividual constant parameters were investigated. Pelvic incidence is defined as the angle between the perpendicular to the sacral plate at its midpoint and the line connecting this point to the middle axis of the femoral heads. Acetabular anteversion is defined as the angle between the perpendicular to the best-fit plane on the acetabular rim and the coronal plane measured in strict lateral view. Acetabular inclination is defined as the angle between the perpendicular to the best-fit plane on the acetabular rim and the sagittal plane in strict frontal view. Data were further analysed with regard to different subgroup's age, sex and ethnicity. A positive correlation between PI and acetabular anteversion could be demonstrated. Further, PI and also the acetabular parameters anteversion and inclination were found to be significantly higher in the European individuals than in the Asian. The results of the present study demonstrate a relation between the anatomical configuration of the constant pelvic parameters building up the connection points to the next proximal respectively caudal skeleton section. The findings might lead to more comprehensive treatment strategies in case of trauma or degenerative pathologies of the pelvis in the future.


Subject(s)
Acetabulum , Pelvic Bones , Acetabulum/diagnostic imaging , Aged , Female , Hip Joint , Humans , Male , Models, Statistical , Pelvic Bones/diagnostic imaging , Pelvis
2.
Sci Rep ; 11(1): 16677, 2021 08 17.
Article in English | MEDLINE | ID: mdl-34404906

ABSTRACT

Retrograde transpubic screw fixation is a common procedure for the treatment of anterior pelvic ring fractures. With its sparing surgical approach and significant pain relief after screw fixations allowing early mobilisation, it has gained importance especially in the treatment of insufficiency fractures in elderly patients. However, positioning of transpubic screw osteosynthesis is not always possible due to narrowness and curvature of the screw corridor. The aim of the present study was to evaluate availability and length of the screw corridor using a 3D statistical model of the pelvic ring consisting out of 150 uninjured pelves. Virtual bore probes with a diameter of 7.5 mm were analysed as to accessibility, length and grey value distribution in Hounsfield Unit (HU). A transpubic corridor with a diameter of ≥ 7.5 mm was available in 185 of 300 investigated superior pubic rami with mean screw length of 131.7 mm. Accessibility of the screw corridor was higher in males than in females. However, screw length showed no systematic differences between the sexes or ethnicities. Analysis of the grey value distribution demonstrated the strongest bone to be located at the lateral ilium and the supraacetabular region.

3.
J Orthop Surg Res ; 16(1): 216, 2021 Mar 24.
Article in English | MEDLINE | ID: mdl-33761965

ABSTRACT

BACKGROUND: A detailed understanding of scaphoid anatomy helps anatomic fracture reduction, and optimal screw position. Therefore, we analysed (1) the size and shape variations of the cartilage and osseous surface, (2) the distribution of volumetric bone mineral density (vBMD) and (3) if the vBMD values differ between a peripheral and a central screw pathway? METHODS: Forty-three fresh frozen hand specimens (17 females, 26 males) were analysed with high-resolution peripheral quantitative computed tomography (HR-pQCT) and dissected to compute a 3D-statistical osseous and cartilage surface model and a 3D-averaged vBMD model of the scaphoid. 3D patterns were analysed using principal component analysis (PCA). vBMD was analysed via averaging HR-pQCT grey values and virtual bone probing along a central and peripheral pathway. RESULTS: (1) PCA displayed most notable variation in length ranging from 1.7 cm (- 2SD) to 2.6 cm (mean) and 3.7 cm (+ 2SD) associated with differences of the width and configuration of the dorsal surface (curved and narrow (4 mm) to a wider width (9 mm)). (2) High vBMD was located in the peripheral zone. Lowest vBMD was observed in the centre and waist. (3) Virtual probing along a peripheral pathway near to the cartilage surfaces for the capitate and lunate allowed the center region to be bypassed, resulting in increased vBMD compared to a central pathway. CONCLUSION: High anatomical variations regarding the osseous and cartilage surfaces were associated with three distinct concentrically arranged zones with notable different vBMD. The complex scaphoid anatomy with its waist might alter the strategy of fracture fixation, education and research.


Subject(s)
Bone Density , Bone Screws , Fracture Fixation/methods , Imaging, Three-Dimensional , Scaphoid Bone/anatomy & histology , Scaphoid Bone/surgery , Tomography, X-Ray Computed/methods , Female , Humans , Male , Scaphoid Bone/diagnostic imaging , Scaphoid Bone/metabolism
4.
J Orthop Res ; 39(12): 2681-2692, 2021 12.
Article in English | MEDLINE | ID: mdl-33586812

ABSTRACT

Transsacral corridors at levels S1 and S2 represent complex osseous spaces allowing percutaneous fixation of non- or minimally-displaced fragility fractures of the sacrum. To safely place transsacral implants, they must be completely intraosseous. However, standard radiographs and CT do not properly demonstrate the corridor's intricate configuration. Our goal was to facilitate the three-dimensional assessment of transsacral corridors using artificial intelligence and the planning of transsacral implant positioning. In total, 100 pelvic CTs (49 women, mean age: 58.6 ± SD 14.8 years; 51 men, mean age: 60.7 ± SD 13 years) were used to compute a 3D statistical model of the pelvic ring. On the basis of morphologic features (=predictors) and principal components scores (=response), regression learners were interactively trained, validated, and tuned to predict/sample personalized 3D pelvic models. They were matched via thin-plate spline transformation to a series of 20 pelvic CTs with fragility fractures of the sacrum (18 women and 2 men, age: 69-9.5 years, mean age: 78.65 ± SD 8.4 years). These models demonstrated the availability, dimension, cross-section, and symmetry of transsacral corridors S1 and S2, as well as the planned implant position, dimension, axes, and entry and exit points. The complete intraosseous pathway was controlled in CT reconstructions. We succeeded to establish a workflow determining transsacral corridors S1 and S2 using artificial intelligence and 3D statistical modeling.


Subject(s)
Fractures, Bone , Pelvic Bones , Aged , Artificial Intelligence , Bone Screws , Female , Fracture Fixation, Internal/methods , Humans , Male , Middle Aged , Sacrum/anatomy & histology , Sacrum/diagnostic imaging , Tomography, X-Ray Computed/methods
5.
J Anat ; 238(5): 1225-1232, 2021 05.
Article in English | MEDLINE | ID: mdl-33382451

ABSTRACT

The human pelvis is a complex anatomical structure that consists of the innominate bones, sacrum and coccyx to form the pelvic ring. Even though considered to be a symmetric entity, asymmetry of the pelvic ring (APR) might occur to alter its anatomy, function, or biomechanics or to impact assessment and treatment of clinical cases. APR and its assessment is complicated by the intricate anatomy of the pelvic ring. There is only limited information and understanding about APR with no established evaluation methods existing. The objective of the present study was to adopt CT-based 3D statistical modeling and analysis to assess APR within the complex anatomy of the pelvic ring. We were interested to establish a better understanding of APR with knowledge and applications transferred to human anatomy, related research, and development subjects and to clinical settings. A series of 150 routine, clinical, pelvic CT protocols of European and Asian males and females (64 ± 15 (20-90) years old) were post-processed to compute gender- and ancestry-specific 3D statistical models of the pelvic ring. Evaluations comprised principal component analysis (PCA) that included size, shape, and asymmetry patterns and their variations to be assessed. Four different CT-based 3D statistical models of the entire pelvic ring were computed according to the gender and ancestry specific groups. PCA mainly displayed size and shape variations. Examination of additional PCA modes permitted six distinct asymmetry patterns to be identified. They were located at the sacrum, iliac crest, pelvic brim, pubic symphysis, inferior pubic ramus, and near to the acetabulum. Accordingly, the pelvic ring demonstrated not to be entirely symmetric. Assessment of its asymmetry proved to be a challenging task. Using CT-based 3D statistical modeling and PCA, we identified six distinct APRs that were located at different anatomical regions. These regions are more prone to APRs than other sites. Minor asymmetry patterns have to be distinguished from the distinct APRs. Side differences with regard to size, shape, and/or position require to be taken into account. APRs may be due different load mechanisms applied via spine or lower extremity or locally. There is a need for simpler and efficient, yet reliable methods to be routinely transferred to human anatomy, related research, and development subjects and to clinical settings.


Subject(s)
Pelvic Bones/diagnostic imaging , Pelvis/diagnostic imaging , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Models, Statistical , Tomography, X-Ray Computed , Young Adult
6.
J Orthop Translat ; 20: 100-106, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31908940

ABSTRACT

BACKGROUND/OBJECTIVE: Artificial bone models (ABMs) are used in orthopaedics for research of biomechanics, development of implants and educational purposes. Most of the commercially available ABMs approximate the morphology of Europeans, but they may not depict the Asian anatomy. Therefore, our aim was to develop the first Asian ABM of the pelvis and compare it with the existing pelvic ABM (Synbone®; Caucasian male). METHODS: One hundred clinical computed tomography (CTs) of adult pelvises (male n â€‹= â€‹50, female n â€‹= â€‹50) of Malay, Chinese and Indian descent were acquired. CTs were segmented and defined landmarks were placed. Three 3D statistical pelvic model and mean models (overall, male, female) were generated. Anatomical variations were analysed using principal component analysis. To measure gender-related differences and differences to the existing ABM, distances between the anterior superior iliac spines (ASIS), the anterior inferior iliac spines (AIIS), the promontory and the symphysis (conjugate vera, CV) as well as the ischial spines (diameter transversa, DT) were quantified. RESULTS: Principal component analysis displayed large variability regarding the pelvic shape and size. Female and male statistical models were similar in ASIS (225 â€‹± â€‹20; 227 â€‹± â€‹13 â€‹mm; P â€‹= â€‹0.4153) and AIIS (185 â€‹± â€‹11; 187 â€‹± â€‹10 â€‹mm; P â€‹= â€‹0.3982) and differed in CV (116 â€‹± â€‹10; 105 â€‹± â€‹10 â€‹mm; P â€‹< â€‹0.0001) and DT (105 â€‹± â€‹7; 88 â€‹± â€‹8 â€‹mm; P â€‹< â€‹0.0001). Comparing the unisex mean model with the pre-existing ABM, the ASIS (226; 275 â€‹mm; P â€‹< â€‹0.0001), the AIIS (186; 209 â€‹mm; P â€‹< â€‹0.0001) and the CV (111; 105 â€‹mm; P â€‹< â€‹0.0001) differed significantly. Both models were similar regarding DT (97; 95 â€‹mm; P â€‹= â€‹0.6927). The analysis revealed notable gender- and size-dependent anatomical variations within the Asian population. Chinese, Malay and Indian descents did not differ notably. The overall Asian model was smaller than the existing ABM. THE TRANSLATION POTENTIAL OF THIS ARTICLE: Owing to the large differences between the Asian ABM and the pre-existing ABM, as well as differences between genders, the use of an Asian- and gender-specific ABM is important to consider in research, biomechanics and implant development for this population.

7.
Arch Orthop Trauma Surg ; 139(10): 1385-1391, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31111201

ABSTRACT

INTRODUCTION: The use of trans-sacral implants to treat fractures of the sacrum is limited by the variable pelvic anatomy. We were interested in how many trans-sacral implants can be placed per pelvis? If a trans-sacral implant cannot be placed in S1, where is the cortex perforated, and is the use of sacroiliac screws safe in these pelves? MATERIALS AND METHODS: 3D pelvic models were created from CT scans of 156 individuals without fractures (92 European and 64 Japanese, 79 male and 77 female, mean age 66.7 ± 13.7 years). Trans-sacral implants with a diameter of 7.3 mm were positioned virtually with and without a surrounding safe zone of 12 mm diameter. RESULTS: Fifty-one percent of pelves accommodated trans-sacral implants in S1 with a safe zone. Twenty-two percent did not offer enough space in S1 for an implant even when ignoring the safe zone. Every pelvis had sufficient space for a trans-sacral implant in S2, in 78% including a safe zone as well. In S1, implant perforation was observed in the sacral ala and iliac fossa in 69%, isolated iliac fossa perforation in 23% and perforation of the sacral ala in 8%. Bilateral sacroiliac screw placement was always possible in S1. CONCLUSIONS: The use of trans-sacral implants in S1 requires meticulous preoperative planning to avoid injury of neurovascular structures. S2 more consistently offers space for trans-sacral implants.


Subject(s)
Bone Screws , Fracture Fixation, Internal/methods , Hip Fractures/surgery , Imaging, Three-Dimensional/methods , Sacrum/surgery , Surgery, Computer-Assisted/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Ilium/surgery , Male , Middle Aged , Tomography, X-Ray Computed
8.
Clin Anat ; 32(3): 361-368, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30521090

ABSTRACT

Distal radius fractures are common and fracture patterns and fixation can be complex. Computerized anatomy evaluation (CAE) might offer non-invasive and enhanced anatomy assessment that might help with implant selection and placement and screw length determination. Our goal was to test the accuracy of two CAE methods for anatomical volar plate positioning and screw lengths measurement of the distal radius. We included 56 high-resolution peripheral quantitative computed tomography scans of intact, human distal radii. Plates were placed manually onto 3D printed models (method 1), which was compared with automated computerized plate placement onto the 3D computer models (method 2). Subsequently, screw lengths were determined digitally for both methods. Screw lengths evaluations were compared via Bland-Altman plots. Both CAE methods resulted in identical volar plate selection and in anatomical plate positioning. For screw length the concordance correlation coefficient was ≥0.91, the location shift ≤0.22 mm, and the scale shift ≤0.16. The differences were smaller than ±1 mm in all samples. Both CAE methods allow for comparable plate positioning and subsequent screw length measurement in distal radius volar plating. Both can be used as a non-invasive teaching environment for volar plate fixation. Method 2 even offers fully computerized assessments. Future studies could compare our models to other anatomical areas, post-operative volar plate positioning, and model performance in actual distal radius fracture instead of intact radii. Clin. Anat. 32:361-368, 2019. © 2018 The Authors. Clinical Anatomy published by Wiley Periodicals, Inc. on behalf of American Association of Clinical Anatomists.


Subject(s)
Radius Fractures/diagnostic imaging , Radius/anatomy & histology , Bone Plates , Bone Screws , Cadaver , Fracture Fixation, Internal/methods , Humans , Imaging, Three-Dimensional , Orthopedic Procedures/education , Radius/diagnostic imaging , Radius Fractures/surgery , Tomography, X-Ray Computed
9.
J Anat ; 234(3): 376-383, 2019 03.
Article in English | MEDLINE | ID: mdl-30575034

ABSTRACT

The pelvic ring is a highly complex construct with a central role for human stability and mobility. The observable interindividual differences in skeletal anatomy are caused by anatomical variation in the innominate bones as well as the sacrum, further to differences in the spatial arrangement of these bones to each other. The aim of this study was to generate a 3D statistical model of the entire pelvic ring in order to analyse the observed interindividual differences and anatomical variation. A series of 50 anonymized pelvic CT scans of uninjured Japanese adults [30 males, 20 females, average age of 74.9 years, standard deviation (SD) 16.9 years] were processed and analysed, resulting in a 3D statistical overall mean model and separate male and female mean models. Principal component analysis (PCA) of the overall statistical model predominantly showed size variation (20.39%) followed by shape variation (14.13%), and a variation of the spatial arrangement of the sacrum to the innominate bones in different anatomical peculiarities (11.39 and 8.85%). In addition, selected internal and external pelvic parameters were manually measured with the objective of further evaluating and quantifying the observed interindividual as well as the known sex-specific differences. A separate statistical model of the grey value distribution based on the given Hounsfield unit (HU) values was calculated for assessing bone mass distribution, thus an indication of bone quality utilizing grey values as a quantitative description of radiodensity was obtained. A consistent pattern of grey value distribution was shown, with the highest grey values observed between the sacro-iliac joint and the acetabulum along the pelvic brim. Low values were present in the sacral ala, in the area of the iliac fossa as well as in the pubic rami next to the symphysis. The present model allows a differentiated analysis of the observed interindividual variation of the pelvic ring and an evaluation of the grey value distribution therein. Besides providing a better understanding of anatomical variation, this model could be also used as a helpful tool for educational purposes, preoperative planning and implant design.


Subject(s)
Anatomic Variation , Imaging, Three-Dimensional/methods , Pelvic Bones/anatomy & histology , Pelvis/anatomy & histology , Sacrum/anatomy & histology , Adult , Aged , Biometry , Female , Gender Identity , Humans , Ilium/anatomy & histology , Male , Models, Statistical , Principal Component Analysis , Sacroiliac Joint/anatomy & histology , Tomography, X-Ray Computed/methods
10.
J Orthop Surg Res ; 13(1): 119, 2018 May 21.
Article in English | MEDLINE | ID: mdl-29784006

ABSTRACT

BACKGROUND: Acetabular fracture surgery is directed toward anatomical reduction and stable fixation to allow for the early functional rehabilitation of an injured hip joint. Recent biomechanical investigations have shown the superiority of using an additional screw in the infraacetabular (IA) region, thereby transfixing the separated columns to strengthen the construct by closing the periacetabular fixation frame. However, the inter-individual existence and variance concerning secure IA screw corridors are poorly understood. METHODS: This computer-aided 3-D radiomorphometric study examined 124 CT Digital Imaging and Communications in Medicine (DICOM) datasets of intact human pelves (248 acetabula) to visualize the spatial IA corridors as the sum of all intraosseous screw positions. DICOM files were pre-processed using the Amira® 4.2 visualization software. Final corridor computation was accomplished using a custom-made software algorithm. The volumetric measurement data of each corridor were calculated for further statistical analyses. Correlations between the volumetric values and the biometric data were investigated. Furthermore, the influence of hip dysplasia on the IA corridor configuration was analyzed. RESULTS: The IA corridors consistently showed a double-cone shape with the isthmus located at the acetabular fovea. In 97% of male and 91% of female acetabula, a corridor for a 3.5-mm screw could be found. The number of IA corridors was significantly lower in females for screw diameters ≥ 4.5 mm. The mean 3.5-mm screw corridor volume was 16 cm3 in males and 9.2 cm3 in female pelves. Corridor volumes were significantly positively correlated with body height and weight and with the diameter of Köhler's teardrop on standard AP pelvic X-rays. No correlation was observed between hip dysplasia and the IA corridor extent. CONCLUSION: IA corridors are consistently smaller in females. However, 3.5-mm small fragment screws may still be used as the standard implant because sex-specific differences are significant only with screw diameters ≥ 4.5 mm. Congenital hip dysplasia does not affect secure IA screw insertion. The described method allows 3-D shape analyses with highly reliable results. The visualization of secure IA corridors may support the spatial awareness of surgeons. Volumetric data allow the reliable assessment of individual IA corridors using standard AP X-ray views, which aids preoperative planning.


Subject(s)
Acetabulum/diagnostic imaging , Bone Screws , Fracture Fixation/methods , Fractures, Bone/diagnostic imaging , Imaging, Three-Dimensional/methods , Tomography, X-Ray Computed/methods , Acetabulum/injuries , Acetabulum/surgery , Aged , Cohort Studies , Databases, Factual , Female , Fracture Fixation/instrumentation , Fractures, Bone/surgery , Humans , Male , Middle Aged
11.
Arch Orthop Trauma Surg ; 138(7): 971-977, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29700604

ABSTRACT

INTRODUCTION: Patients suffering from osteoporosis-associated fragility fractures of the sacrum (FFS; also termed sacral insufficiency fractures) are increasingly observed. They have typical fracture patterns with fracture lines located in the sacral ala. When treating these patients operatively, iliosacral screw loosening is not uncommon. We aimed to study the sacral bone mass in patients presenting with a FFS using 3D statistical models. MATERIALS AND METHODS: 3D models of averaged Hounsfield units (HU) were generated based on CT scans from 13 patients with a unilateral FFS (mean age 79.6 years; 11 females, 2 males). The control group without fractures consisted of 28 males and 32 females (mean age of 68.3 years). A virtual bone probe along the trans-sacral corridors S1 and S2 was taken. RESULTS: The bone mass distribution in the fractured sacra was similar to the control group, however, with overall lower HU. Large zones of negative HU were located in the sacral ala. In the fractured sacra, the HU in the sacral ala was significantly lower on the non-injured side when comparing to the fractured side (p < 0.001) as well as compared to the non-fractured group (p < 0.001). Low bone mass was observed in sacral body S1 (40 HU) and S2 (20 HU). CONCLUSIONS: The extensive area of negative HU may explain the fracture location in the sacral ala. The low HU in the sacral bodies advocates the use of trans-sacral implants or augmented iliosacral screws to enhance the strength of fracture fixation. The increased HU in the fractured ala could be explained by fracture-asssociated hemorrhage and can be used as a diagnostic tool.


Subject(s)
Osteoporotic Fractures/diagnostic imaging , Sacrum/injuries , Spinal Fractures/diagnostic imaging , Aged , Aged, 80 and over , Bone Density , Bone Screws , Female , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Humans , Male , Middle Aged , Models, Statistical , Osteoporotic Fractures/surgery , Retrospective Studies , Sacrum/diagnostic imaging , Sacrum/surgery , Spinal Fractures/surgery , Tomography, X-Ray Computed
12.
Spine J ; 17(8): 1141-1147, 2017 08.
Article in English | MEDLINE | ID: mdl-28373081

ABSTRACT

BACKGROUND CONTEXT: Trans-sacral implants are increasingly used to treat fractures of the sacrum, especially for osteoporosis-associated fragility fractures. However, the complex and highly variable sacral anatomy limits their use. It is still not clear which morphologic characteristics are critical to determine the availability and dimensions of trans-sacral corridors. PURPOSE: This study aims to assess sacral anatomy and its influence on trans-sacral corridors. STUDY DESIGN: This study used a computed tomography (CT)-based three-dimensional (3D) statistical size and shape model of the sacrum with multiple morphometric measurements. MATERIALS AND METHODS: A 3D statistical model was computed using clinical CT data of 92 intact pelvises (mean age 61.5 years). Multiple measurements of the sacrum and the trans-sacral corridors were taken. Descriptive statistics and linear regression were calculated. Shape and size were analyzed using principal component analysis. RESULTS: The limiting craniocaudal diameter of the trans-sacral corridor was 13.1 mm (±5 mm) in S1 and 13.8 mm (±2.4 mm) in S2. In S1, the craniocaudal diameter correlated with larger sacral curvature (SC), pelvic incidence (PI), and cranially located auricular surfaces. The presence of an accessory articulation with L5 was associated with a larger trans-sacral corridor S1. In contrast, the craniocaudal diameter of the S2 corridor correlated with more caudally situated auricular surfaces and lower PI. The sacral shape, as demonstrated by the statistical model, was highly variable, which affected the size and availability of trans-sacral corridor S1. Important determinants of trans-sacral corridor S1 were the craniocaudal position of the auricular surfaces and the shape of the sacral ala, which were influenced by SC, sacral height, and PI. CONCLUSIONS: The human sacrum is highly variable in size and shape. The dimensions of trans-sacral corridors depend on the sacral shape and specific morphologic characteristics. Understanding of morphologic variants helps with preoperative assessments of the trans-sacral corridors. When planning to use trans-sacral implants, because of variable sacral anatomy and dimensions of the trans-sacral corridors, thorough preoperative planning is mandatory.


Subject(s)
Models, Statistical , Sacrum/diagnostic imaging , Aged , Female , Humans , Male , Middle Aged , Pelvis/anatomy & histology , Pelvis/diagnostic imaging , Sacrococcygeal Region/anatomy & histology , Sacrococcygeal Region/diagnostic imaging , Sacrum/anatomy & histology , Tomography, X-Ray Computed/methods
13.
J Orthop Res ; 35(11): 2577-2584, 2017 11.
Article in English | MEDLINE | ID: mdl-28247980

ABSTRACT

Trans-sacral implants can be used alternatively to sacro-iliac screws in the treatment of osteoporosis-associated fragility fractures of the pelvis and the sacrum. We investigated trans-sacral corridor dimensions, the number of individuals amenable to trans-sacral fixation, as well as the osseous boundaries and shape of the S1 corridor. 3D models were reconstructed from pelvic CT scans from 92 Europeans and 64 Japanese. A corridor of <12 mm was considered critical for trans-sacral implant positioning, and <8 mm as impossible. A statistical model of trans-sacral corridor S1 was computed. The limiting cranio-caudal diameter was 11.6 mm (±5.4) for S1 and 14 mm (±2.4) for S2. Trans-sacral implant positioning was critical in 52% of cases for S1, and in 21% for S2. The S1 corridor was impossible in 26%, with no impossible corridor in S2. Antero-superiorly, the S1 corridor was limited not only by the sacrum but in 40% by the iliac fossa. The statistical model demonstrated a consistent oval shape of the trans-section of corridor S1. Considering the variable in size and shape of trans-sacral corridors in S1, a thorough anatomical knowledge and preoperative planning are mandatory using trans-sacral implants. In critical cases, S2 is a veritable alternative. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2577-2584, 2017.


Subject(s)
Sacrum/diagnostic imaging , Adult , Aged , Aged, 80 and over , Female , Fracture Fixation, Internal , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Reference Values , Retrospective Studies , Sacrum/anatomy & histology , Sacrum/surgery , Spinal Fractures/surgery , Tomography, X-Ray Computed
14.
J Orthop Res ; 35(10): 2154-2163, 2017 10.
Article in English | MEDLINE | ID: mdl-28054384

ABSTRACT

The surgical fracture fixation of the odontoid process (dens) of the second cervical vertebra (C2/axis) is a challenging procedure, particularly in elderly patients affected by bone loss, and includes screw positioning close to vital structures. The aim of this study was to provide an extended anatomical knowledge of C2, the bone mass distribution and bone loss, and to understand the implications for anterior screw fixation. One hundred and twenty standard clinical quantitative computed tomography (QCT) scans of the intact cervical spine from 60 female and 60 male European patients, aged 18-90 years, were used to compute a three-dimensional statistical model and an averaged bone mass model of C2. Shape and size variability was assessed via principal component analysis (PCA), bone mass distribution by thresholding and via virtual core drilling, and the screw placement via virtual positioning of screw templates. Principal component analysis (PCA) revealed a highly variable anatomy of the dens with size as the predominant variation according to the first principal component (PC) whereas shape changes were primarily described by the remaining PCs. The bone mass distribution demonstrated a characteristic 3D pattern, and remained unchanged in the presence of bone loss. Virtual screw positioning of two 3.5 mm dens screws with a 1 mm safety zone was possible in 81.7% in a standard, parallel position and in additional 15.8% in a twisted position. The approach permitted a more detailed anatomical assessment of the dens axis. Combined with a preoperative QCT it may further improve the diagnostic procedure of odontoid fractures. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2154-2163, 2017.


Subject(s)
Axis, Cervical Vertebra/diagnostic imaging , Adolescent , Adult , Aged , Aged, 80 and over , Axis, Cervical Vertebra/injuries , Bone Density , Bone Screws , Female , Fracture Fixation, Internal , Humans , Male , Middle Aged , Reference Values , Retrospective Studies , Spinal Fractures/surgery , Tomography, X-Ray Computed , Young Adult
15.
Calcif Tissue Int ; 99(6): 588-597, 2016 12.
Article in English | MEDLINE | ID: mdl-27572994

ABSTRACT

Osteoporosis leads to bone loss and structural deterioration, which increase the risk of fractures. The aim of this study was to characterize the three-dimensional (3D) bone mass distributions of the distal tibia in normal, osteopenic, and osteoporotic conditions. High-resolution peripheral quantitative computed tomography (HR-pQCT) of the 33 % of the distal tibia and local dual-energy X-ray absorptiometry were applied to 53 intact, fresh-frozen tibiae. The HR-pQCTs were graded to assign local T-scores and merged into three equally sized average normal, osteopenic, and osteoporotic surface models. Volumetric bone mineral density (vBMD) was determined using categorized T-scores, volumetric visualization, and virtual bore probes at the dia-, meta-, and epiphyseal sites (T-DIA, T-META, and T-EPI). We observed a distinct 3D bone mass distribution that was gradually uninfluenced by T-score categories. T-DIA was characterized by the lowest bone mass located in the medullary cavity and a wide homogenous cortex containing the maximum vBMD. The T-META showed decreased cortical thickness and maximal vBMD. At the T-EPI, the relatively low vBMD of the mostly trabecular bone was similar to the maximal cortical vBMD in this sub-region. Four trabecular regions of low bone mass were identified in the recesses. The bone content gradually decreased at all sites, whereas the pattern of bone mass distribution remained essentially unchanged, with the exception of disproportionate losses at T-DIA, T-META, and T-EPI that consistently showed increased endocortical, intracortical, and trabecular bone loss. Extra information can be obtained from the specific pattern of bone mass distribution, potential disproportionate bone losses, and method used.


Subject(s)
Bone Diseases, Metabolic/diagnostic imaging , Bone Diseases, Metabolic/pathology , Osteoporosis/diagnostic imaging , Osteoporosis/pathology , Tibia/diagnostic imaging , Tibia/pathology , Absorptiometry, Photon , Bone Density , Computer Simulation , Humans , In Vitro Techniques , Tomography, X-Ray Computed
16.
J Bone Joint Surg Am ; 98(7): 584-90, 2016 Apr 06.
Article in English | MEDLINE | ID: mdl-27053587

ABSTRACT

BACKGROUND: Fragility fractures of the sacrum are increasing in prevalence due to osteoporosis and epidemiological changes and are challenging in their treatment. They exhibit specific fracture patterns with unilateral or bilateral fractures lateral to the sacral foramina, and sometimes an additional transverse fracture leads to spinopelvic dissociation. The goal of this study was to assess sacral bone mass distribution and corresponding changes with decreased general bone mass. METHODS: Clinical computed tomography (CT) scans of intact pelves in ninety-one individuals (mean age and standard deviation, 61.5 ± 11.3 years) were used to generate three-dimensional (3D) models of the sacrum averaging bone mass in Hounsfield units (HU). Individuals with decreased general bone mass were identified by measuring bone mass in L5 (group 1 with <100 HU; in contrast to group 2 with ≥100 HU). RESULTS: In group 1, a large zone of negative Hounsfield units was located in the paraforaminal lateral region from S1 to S3. Along the trans-sacral corridors, a Hounsfield unit peak was observed laterally, corresponding to cortical bone of the auricular surface. The lowest Hounsfield unit values were found in the paraforaminal lateral region in the sacral ala. An intermediate level of bone mass was observed in the area of the vertebral bodies, which also demonstrated the largest difference between groups 1 and 2. Overall, the Hounsfield units were lower at S2 than S1. CONCLUSIONS: The models of averaged bone mass in the sacrum revealed a distinct 3D distribution pattern. CLINICAL RELEVANCE: The negative values in the paraforaminal lateral region may explain the specific fracture patterns in fragility fractures of the sacrum involving the lateral areas of the sacrum. Transverse fractures located between S1 and S2 leading to spinopelvic dissociation may occur because of decreased bone mass in S2. The largest difference between the studied groups was found in the vertebral bodies and might support the use of transsacral or cement-augmented implants.


Subject(s)
Fractures, Bone/etiology , Fractures, Bone/therapy , Models, Anatomic , Sacrum/diagnostic imaging , Sacrum/injuries , Tomography, X-Ray Computed , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Retrospective Studies , Young Adult
17.
J Orthop Res ; 34(7): 1216-23, 2016 07.
Article in English | MEDLINE | ID: mdl-26714141

ABSTRACT

UNLABELLED: Previous studies have suggested clavicular morphology is highly variable, particularly in the lateral retrocurved section. Current clavicle fracture plating systems require three dimensional intra-operative contouring to achieve adequate fit and necessitate variable soft tissue dissection placing fracture perfusion and muscular attachments at risk. The aim of this study was to search for a surgically relevant superficial shape pattern. This is a retrospective CT-based analysis of 174 non-pathological clavicles in 95 adults (45 females, 50 males). Using the principle of cylindrical parameterisation generated 3-D computer models, we identified an implant preferred pathway (IPP), defined as a continuous linear region where the least possible soft tissue disruption would be necessary for plate fixation. The IPP mean form was within 3.04 mm (SD ± 1.34) on all clavicles. Clavicle length, and not shape, was found to be the biggest variable (correlation between size and form co-ordinates r = 0.99, p < 0.05), accounting for 79% of overall variability. This length variation was mainly located in the medial antecurved section. Superior convexity and recurvatum were the main shape variables, however they only contributed 8% and 5% to the overall variation, respectively. Three IPP lengths were shown to match all clavicles when aligned at the acromial end first. In contrast to previous studies, we have shown that the IPP is fairly consistent with respect to the general shape with the exception of length variation which mainly affected the medial antecurved section. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1216-1223, 2016. CLINICAL RELEVANCE: Future pre-contoured fracture fixation systems should provide variable length plates with a constant lateral section retrocurve and a variable medial antecurve.


Subject(s)
Clavicle/diagnostic imaging , Adult , Aged , Aged, 80 and over , Anatomic Variation , Female , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Principal Component Analysis , Retrospective Studies , Tomography, X-Ray Computed
18.
J Orthop Translat ; 4: 46-56, 2016 Jan.
Article in English | MEDLINE | ID: mdl-30035065

ABSTRACT

BACKGROUND/OBJECTIVE: Spatial knowledge of the anatomy of the proximal humerus is critical for effective treatment, particularly in patients affected by fragility fractures. High-resolution peripheral quantitative computed tomography (HR-pQCT) imaging with medical image processing techniques enable three dimensional (3D) analysis of volumetric bone mineral density (vBMD) of bones of different sizes and shapes. METHODS: To elucidate the bony anatomy and to create 3D reference data, we conducted a computerized HR-pQCT-based study in intact postmortem samples of the proximal humerus to highlight the anatomy with particular emphasis on the size, shape, and bone stock distribution pattern.Fifty-eight defrozen intact humerus samples from 28 female and 30 male donors, who were aged 61-98 years old (mean age ± standard deviation, 80.6 ± 9 years), were scanned in the proximal third using the extended standard HR-pQCT protocol. A 3D statistical bone and averaged bone density models with low, middle, and high total vBMDs were computed. We examined the 3D patterns of size and shape variations using principal component analysis, and the vBMD distributions and variabilities using volume-rendering and virtual bore probing. RESULTS: The computer models revealed a highly variable bony anatomy in which size was the predominant variation in the first principal component (PC). In the second PC, we observed notable variabilities in the shape of the head and shaft inclination. A distinct 3D pattern of bone stock distribution was detected in which the lowest vBMD values were identified in the medullary cavity, middle values were identified in the central zone, and the highest values were identified in the cortex and humeral head-particularly in the subarticular zones. In the presence of bone loss, the vBMD values were ubiquitously decreased, but the pattern of 3D bone stock distribution was maintained. CONCLUSION: The new anatomical 3D data that we acquired will improve the understanding of the normal bony anatomy of the proximal humerus. The extended HR-pQCT protocol and computer models may be used for other skeletal sites and used as 3D reference models that can be applied to systematically improve implant design and anchorage.

19.
J Orthop Res ; 32(11): 1543-8, 2014 Nov.
Article in English | MEDLINE | ID: mdl-24962021

ABSTRACT

The complex anatomy of the sacrum makes surgical fracture fixation challenging. We developed statistical models to investigate sacral anatomy with special regard to trans-sacral implant fixation. We used computed tomographies of 20 intact adult pelves to establish 3D statistical models: a surface model of the sacrum and the trans-sacral corridor S1, including principal component analysis (PCA), and an averaged gray value model of the sacrum given in Hounsfield Units. PCA demonstrated large variability in sacral anatomy markedly affecting the diameters of the trans-sacral corridors. The configuration of the sacral alae and the vertical position of the auricular surfaces were important determinants of the trans-sacral corridor dimension on level S1. The statistical model of trans-sacral corridor S1 including the adjacent parts of the iliac bones showed main variation in length; however, the diameter was the main criterion for the surgically available corridor. The averaged gray value model revealed a distinct pattern of bone mass distribution with lower density particularly in the sacral alae. These advanced 3D statistical models provide a thorough anatomical understanding demonstrating the impact of sacral anatomy on positioning trans-sacral implants.


Subject(s)
Imaging, Three-Dimensional , Models, Statistical , Sacrum/surgery , Adult , Aged , Bone Density , Bone Screws , Female , Fracture Fixation, Internal , Humans , Male , Middle Aged , Principal Component Analysis , Radiographic Image Interpretation, Computer-Assisted , Retrospective Studies , Tomography, X-Ray Computed
20.
Br J Ophthalmol ; 97(5): 659-62, 2013 May.
Article in English | MEDLINE | ID: mdl-23428985

ABSTRACT

AIM: Three-dimensional (3D) CT reconstruction of the bony orbit for accurate measurement and classification of the complex orbital morphology may not be suitable for daily practice. We present an easily measurable two-dimensional (2D) reference dataset of the bony orbit for study of individual orbital morphology prior to decompression surgery in Graves' orbitopathy. METHODS: CT images of 70 European adults (140 orbits) with unaffected orbits were included. On axial views, the following orbital dimensions were assessed: orbital length (OL), globe length (GL), GL/OL ratio and cone angle. Postprocessed CT data were required to measure the corresponding 3D orbital parameters. The 2D and 3D orbital parameters were correlated. RESULTS: The 2D orbital parameters were significantly correlated to the corresponding 3D parameters (significant at the 0.01 level). The average GL was 25 mm (SD±1.0), the average OL was 42 mm (SD±2.0) and the average GL/OL ratio was 0.6 (SD±0.03). The posterior cone angle was, on average, 50.2° (SD±4.1). Three orbital sizes were classified: short (OL≤40 mm), medium (OL>40 to <45 mm) and large (OL≥45 mm). CONCLUSIONS: We present easily measurable reference data for the orbit that can be used for preoperative study and classification of individual orbital morphology. A short and shallow orbit may require a different decompression technique than a large and deep orbit. Prospective clinical trials are needed to demonstrate how individual orbital morphology affects the outcome of decompression surgery.


Subject(s)
Classification/methods , Decompression, Surgical , Exophthalmos/diagnostic imaging , Graves Ophthalmopathy/diagnostic imaging , Orbit/diagnostic imaging , Tomography, X-Ray Computed , Adult , Aged , Aged, 80 and over , Exophthalmos/surgery , Female , Graves Ophthalmopathy/surgery , Humans , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Male , Middle Aged , Orbit/surgery , Young Adult