1.
CVIR Endovasc ; 7(1): 38, 2024 Apr 20.
Article in English | MEDLINE | ID: mdl-38641706

ABSTRACT

BACKGROUND: Endovascular techniques are advancing with the change of treatment paradigm for abdominal aortic aneurysms. Fenestrated EVAR (fEVAR) and branched EVAR (bEVAR) are used for complex aortic aneurysm repair. Both fEVAR and bEVAR have their own advantages and disadvantages. Semi-branches are a new feature that attempt to combine the advantages of both fEVAR and bEVAR. TECHNIQUE: We describe the use of a 4-vessel semi-branched EVAR in a failed EVAR case with a type 1a endoleak. CONCLUSION: The novel feature of semi-branches in custom-made EVAR devices in endovascular aortic treatment following failed EVAR appear to be a feasible option.

2.
J Vasc Surg ; 79(3): 569-576, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37923021

ABSTRACT

OBJECTIVE: The MANTA device is a plug-based vascular closure device (VCD) designed for large bore femoral arterial access site closure. It showed promising results in transcatheter aortic valve replacement cases. In this study, we report our results and evaluate the MANTA VCD in percutaneous endovascular aortic aneurysm repair (pEVAR). METHODS: All data of consecutive patients who underwent an elective pEVAR between October 2018 and December 2022 were retrospectively reviewed. In all patients at least one common femoral artery was intended to close with the MANTA VCD. Depending on the sheath size, the 14Fr or 18Fr MANTA VCD was used. On the preoperative computed tomography scan, the diameter of the common femoral artery (CFA) was measured and the amount of calcification based on the Peripheral Arterial Calcium Scoring System (PACSS) was scored. Primary outcome was procedural technical success. Procedural technical success was defined as placement of the MANTA closure device resulting in vascular closure with patent CFA, without requiring immediate open or endovascular surgery. The secondary outcomes were access site complications requiring reintervention and all-cause mortality at 30-day follow-up. RESULTS: In total, 152 consecutive patients underwent pEVAR with 291 common femoral artery closure procedures with the Manta VCD. Mean age was 74.1 ± 6.4 years, with a mean body mass index of 27.7 ± 4.4 kg/m2. The mean diameter of the CFA was 10.5 ± 1.9 mm. In 52.6% of the cases, there were no calcification on the preoperative computed tomography scan. The 18Fr and 14Fr Manta VCD were used 169 and 122 times, respectively. The technical success rate was 96.6%. Major vascular complications were reported in 4.5% of the cases, without any death-related events. CONCLUSIONS: This single-center retrospective cohort study analyzed the procedural technical success, major vascular complications and all-cause mortality at 30-day follow-up of the MANTA vascular closure device in 152 pEVAR patients with 291 common femoral artery closure procedures. The technical success rate was 96,6%. Major vascular complications were reported in 4.5% of the cases, without any death related events. We concluded that the MANTA device is a safe and feasible option with a high rate of technical success in patients undergoing pEVAR.


Subject(s)
Aortic Aneurysm , Endovascular Procedures , Vascular Closure Devices , Humans , Aged , Aged, 80 and over , Endovascular Procedures/adverse effects , Hemostatic Techniques , Retrospective Studies , Treatment Outcome , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/surgery , Femoral Artery/diagnostic imaging , Femoral Artery/surgery
SELECTION OF CITATIONS