Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Interv Neurol ; 7(1-2): 26-35, 2018 Feb.
Article in English | MEDLINE | ID: mdl-29628942

ABSTRACT

BACKGROUND: Various techniques are used to enhance the results of mechanical thrombectomy with stent-retrievers, including proximal arrest with balloon guide catheter (BGC), conventional large bore proximal catheter (CGC), or in combination with local aspiration through a large-bore catheter positioned at the clot interface (Aspiration-Retriever Technique for Stroke [ARTS]). We evaluated the impact of ARTS in the North American Solitaire Acute Stroke (NASA) registry. SUMMARY: Data on the use of the aspiration technique were available for 285 anterior circulation patients, of which 29 underwent ARTS technique, 131 CGC, and 125 BGC. Baseline demographics were comparable, except that ARTS patients are less likely to have hypertension or atrial fibrillation. The ARTS group had more ICA occlusions (41.4 vs. 22% in the BGC, p = 0.04 and 26% in CGC, p = 0.1) and less MCA/M1 occlusions (44.8 vs. 68% in BGC and 62% in CGC). Time from arterial puncture to reperfusion or end of procedure with ARTS was shorter than with CGC (54 vs. 91 min, p = 0.001) and was comparable to the BGC time (54 vs. 67, p = 0.11). Final degree of reperfusion was comparable among the groups (TICI [modified Thrombolysis in Cerebral Infarction] score 2b or higher was 72 vs. 70% for CGC vs. 78% for BGC). Procedural complications, mortality, and good clinical outcome at 90 days were similar between the groups. KEY MESSAGES: The ARTS mechanical thrombectomy in acute ischemic stroke patients appears to yield better results as compared to the use of CGCs with no significant difference when compared to BGC. This early ARTS technique NASA registry data are limited by the earlier generation distal large bore catheters and small sample size. Future studies should focus on the comparison of ARTS and BGC techniques.

2.
J Neurointerv Surg ; 9(8): 766-771, 2017 Aug.
Article in English | MEDLINE | ID: mdl-27422970

ABSTRACT

PURPOSE: Monitoring of blood pressure (BP) during procedures is variable, depending on multiple factors. Common methods include sphygmomanometer (BP cuff), separate radial artery catheterization, and side port monitoring of an indwelling sheath. Each means of monitoring has disadvantages, including time consumption, added risk, and signal dampening due to multiple factors. We sought an alternative approach to monitoring during procedures in the catheterization laboratory. METHODS: A new technology involving a 330 µm fiberoptic sensor embedded in the wall of a sheath structure was tested against both radial artery catheter and sphygmomanometer readings obtained simultaneous with readings recorded from the pressure sensing system (PSS). Correlations and Bland-Altman analysis were used to determine whether use of the PSS could substitute for these standard techniques. RESULTS: The results indicated highly significant correlations in systolic, diastolic, and mean arterial pressures (MAP) when compared against radial artery catheterization (p<0.0001), and MAP means differed by <4%. Bland-Altman analysis of the data suggested that the sheath measurements can replace a separate radial artery catheter. While less striking, significant correlations were seen when PSS readings were compared against BP cuff readings. CONCLUSIONS: The PSS has competitive functionality to that seen with a dedicated radial artery catheter for BP monitoring and is available immediately on sheath insertion without the added risk of radial catheterization. The sensor is structurally separated from the primary sheath lumen and readings are unaffected by device introduction through the primary lumen. Time delays and potential complications from radial artery catheterization are avoided.


Subject(s)
Blood Pressure Determination/methods , Blood Pressure/physiology , Catheterization, Peripheral/methods , Fiber Optic Technology/methods , Radial Artery/physiology , Sphygmomanometers , Arterial Pressure/physiology , Blood Pressure Determination/instrumentation , Catheterization, Peripheral/instrumentation , Fiber Optic Technology/instrumentation , Humans , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Radial Artery/surgery
3.
Interv Neurol ; 4(3-4): 75-82, 2016 Mar.
Article in English | MEDLINE | ID: mdl-27051402

ABSTRACT

Mechanical thrombectomy using retrievable stents or stent retriever devices has become the mainstay of intra-arterial therapy for acute ischemic stroke. The recent publication of a series of positive trials supporting intra-arterial therapy as standard of care for the treatment of large vessel occlusion will likely further increase stent retriever use. Rarely, premature stent detachment during thrombectomy may be encountered. In our multicenter case series, we found a rate of detachment of less than 1% (n = 7/1,067), and all were first-generation Solitaire FR devices. A review of the US Food and Drug Administration database of device experience yielded 90 individual adverse reports of detachment. There were 82, 1 and 7 detachments of Solitaire FR (first generation), Solitaire FR2 (second generation) and Trevo devices, respectively. We conclude with a brief overview of the technical and procedural considerations which may be helpful in avoiding this rare complication.

SELECTION OF CITATIONS
SEARCH DETAIL
...