J Am Heart Assoc ; 13(1): e032873, 2024 Jan 02.
Article in English | MEDLINE | ID: mdl-38156545

ABSTRACT

BACKGROUND: Heart failure with preserved ejection fraction ≥50% is prevalent with few evidence-based therapies. In a trial of patients with heart failure with preserved ejection fraction with specialized pacemakers, treatment with accelerated personalized pacing averaging 75 bpm (myPACE) markedly improved quality of life, NT-proBNP (N-terminal pro-brain natriuretic peptide), physical activity, and atrial fibrillation burden compared with the standard lower rate setting of 60 bpm (usual care). METHODS AND RESULTS: In this exploratory study, provider-initiated echocardiographic studies obtained before and after the trial were assessed for changes in left ventricular (LV) structure and function among participants who continued their pacing assignment. The analytic approach aimed to detect differences in standard and advanced echocardiographic parameters within and between study arms. Of the 100 participants, 16 myPACE and 20 usual care arm had a qualifying set of echocardiograms performed a mean (SD) 3 (2.0) years apart. Despite similar baseline echocardiogram measures, sustained exposure to moderately accelerated pacing resulted in reduced septal wall thickness (in cm: myPACE 1.1 [0.2] versus usual care 1.2 [0.2], P=0.008) and lower LV mass to systolic volume ratio (in g/mL: myPACE 4.8 [1.9] versus usual care 6.8 [3.1], P=0.038) accompanied by a minor reduction in LV ejection fraction (in %: myPACE 55 [5] versus usual care 60 [5], P=0.015). These changes were paralleled by improvements in heart failure-related quality of life (myPACE Minnesota Living with Heart Failure Questionnaire improved by 16.1 [13.9] points, whereas usual care worsened by 6.9 [11.6] points, P<0.001). Markers of diastolic function and LV performance were not affected. CONCLUSIONS: Exposure to continuous accelerated pacing in heart failure with preserved ejection fraction is associated with a reduced LV wall thickness and a small amount of LV dilation with small reduction in ejection fraction.


Subject(s)
Atrial Fibrillation , Heart Failure , Humans , Atrial Fibrillation/therapy , Heart Failure/diagnostic imaging , Heart Failure/therapy , Natriuretic Peptide, Brain , Peptide Fragments , Quality of Life , Stroke Volume , Ventricular Function, Left
SELECTION OF CITATIONS
SEARCH DETAIL
...