Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Molecules ; 26(18)2021 Sep 12.
Article in English | MEDLINE | ID: mdl-34577009

ABSTRACT

A fully automated sequential injection system was tested in terms of its application in liberation testing, and capabilities and limitations were discussed for clotrimazole liberation from three semisolid formulations. An evaluation based on kinetic profiles obtained in short and longer sampling intervals and steady-state flux values were applied as traditional methods. The obtained clotrimazole liberation profile was faster in the case of Delcore and slower for Clotrimazol AL and Canesten cream commercial formulations. The steady-state flux values for the tested formulations were 52 µg cm-2 h-1 for Canesten, 35 µg cm-2 h-1 for Clotrimazol AL, and 7.2 µg cm-2 h-1 for Delcore measured in 4 min sampling intervals. A simplified approach for the evaluation of the initial rate based on the gradient between the second and third sampling points was used for the first time and was found to correspond well with the results of the conventional methods. A comparison based on the ratio of the steady-state flux and the initial rate values for Canesten and Clotrimazol AL proved the similarity of the obtained results. The proposed alternative was successfully implemented for the comparison of short-term kinetic profiles. Consequently, a faster and simpler approach for dissolution/liberation testing can be used.


Subject(s)
Antifungal Agents/analysis , Automation, Laboratory/methods , Clotrimazole/analysis , Flow Injection Analysis/methods , Drug Compounding , Drug Liberation , Kinetics , Skin Cream
2.
Anal Bioanal Chem ; 411(6): 1219-1228, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30617392

ABSTRACT

A fully automated method for the determination of lovastatin in dietary supplements containing red yeast rice has been developed. It uses a sequential injection analysis system combined with solid-phase extraction applying highly selective molecularly imprinted polymer sorbent. A miniaturized column for on-line extraction was prepared by packing 4.5 mg of the sorbent in a 5.0 × 2.5-mm-i.d. cartridge, which was used in the flow manifold. Sequential injection analysis manifold enabled all steps of lovastatin extraction and continuous spectrophotometric detection at 240 nm. A limit of detection of 60 µg g-1, a limit of quantitation of 200 µg g-1, and a linear calibration range of 200-2000 µg g-1 were achieved. Intra-day and inter-day precision values (RSD) were ≤ 6.7% and ≤ 4.9%, respectively, and method recovery values of spiked red yeast rice extracts at 200, 1000, and 2000 µg g-1 concentration levels were 82.9, 95.2, and 87.7%. Our method was used for determination of lovastatin lactone in four dietary supplements containing red yeast rice as a natural source of lovastatin, also known as monacolin K. The extracted samples were subsequently analyzed by the reference UHPLC-MS/MS method. Statistical comparison of results (F test, t test, α = 0.05) obtained by both methods did not reveal significant difference. A substantial advantage of the new automated approach is high sample throughput thanks to the analysis time of 7.5 min, miniaturization via down-scaling the extraction column, and smaller sample and solvent consumption, as well as reduced generation of waste. Graphical abstract ᅟ.


Subject(s)
Anticholesteremic Agents/analysis , Biological Products/analysis , Dietary Supplements/analysis , Lovastatin/analysis , Molecular Imprinting/methods , Solid Phase Extraction/methods , Chromatography, High Pressure Liquid/instrumentation , Chromatography, High Pressure Liquid/methods , Equipment Design , Flow Injection Analysis/instrumentation , Flow Injection Analysis/methods , Limit of Detection , Molecular Imprinting/instrumentation , Polymers/chemistry , Solid Phase Extraction/instrumentation , Spectrophotometry, Ultraviolet/instrumentation , Spectrophotometry, Ultraviolet/methods , Tandem Mass Spectrometry/instrumentation , Tandem Mass Spectrometry/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...