Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 32
Filter
1.
Phys Med ; 32(9): 1082-7, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27599608

ABSTRACT

BACKGROUND AND PURPOSE: To study the impact of coronal and sagittal views (CSV) on the gross tumor volume (GTV) delineation on CT and matched PET/CT scans in non-small cell lung cancer. MATERIAL AND METHODS: GTV delineations were performed by 11 experienced radiation oncologists on CT and PET/CT in 22 patients. Two tumor groups were defined: Group I: Primary tumors surrounded by lung or visceral pleura, without venous invasion, and without large extensions to the chest wall or the mediastinum. Group II: Tumors invading the hilar region, heart, large vessels, pericardium, and the mediastinum and/or associated with atelectasis. Tumor volumes and inter-observers variations (SD) were calculated and compared according to the use of axial view only (AW), axial/coronal/sagittal views (ACSW) and ACSW/PET (ACSWP). RESULTS: CSV were not frequently used (57.4% out of 242 delineations on CT). For group I, ACSW didn't improve significantly mean GTVs. SDs were small on CT and on PET (SD=0.3cm). For group II, ACSW had 27-46% smaller observer variation (mean SD=0.7cm) than AW (mean SD=1.1cm). The smaller observer variation of ACSW users was associated with, on average, a 40% smaller delineated volume (p=0.038). Mean GTV of ACSWP was 21% larger than mean GTV of ACSW on CT. CONCLUSIONS: For smaller lung tumors surrounded by healthy lung tissue the effect of multiple axis delineation is limited. However, application of coronal and sagittal windows is highly beneficial for delineation of more complex tumors, with atelectasis and/or pathological lymph nodes even if PET is used.


Subject(s)
Image Processing, Computer-Assisted/methods , Lung/diagnostic imaging , Algorithms , Brachytherapy/methods , Calibration , Computer Simulation , Electrons , Humans , Monte Carlo Method , Photons , Probability , Reproducibility of Results , Software , Uncertainty
2.
Int J Radiat Oncol Biol Phys ; 85(2): 315-20, 2013 Feb 01.
Article in English | MEDLINE | ID: mdl-22682807

ABSTRACT

PURPOSE: Despite conventional radiation therapy, 54 Gy in single doses of 1.8 Gy (54/1.8 Gy) over 6 weeks, most children with diffuse intrinsic pontine glioma (DIPG) will die within 1 year after diagnosis. To reduce patient burden, we investigated the role of hypofractionation radiation therapy given over 3 to 4 weeks. A 1:1 matched-cohort analysis with conventional radiation therapy was performed to assess response and survival. METHODS AND MATERIALS: Twenty-seven children, aged 3 to 14, were treated according to 1 of 2 hypofractionation regimens over 3 to 4 weeks (39/3 Gy, n=16 or 44.8/2.8 Gy, n=11). All patients had symptoms for ≤3 months, ≥2 signs of the neurologic triad (cranial nerve deficit, ataxia, long tract signs), and characteristic features of DIPG on magnetic resonance imaging. Twenty-seven patients fulfilling the same diagnostic criteria and receiving at least 50/1.8 to 2.0 Gy were eligible for the matched-cohort analysis. RESULTS: With hypofractionation radiation therapy, the overall survival at 6, 9, and 12 months was 74%, 44%, and 22%, respectively. Progression-free survival at 3, 6, and 9 months was 77%, 43%, and 12%, respectively. Temporary discontinuation of steroids was observed in 21 of 27 (78%) patients. No significant difference in median overall survival (9.0 vs 9.4 months; P=.84) and time to progression (5.0 vs 7.6 months; P=.24) was observed between hypofractionation vs conventional radiation therapy, respectively. CONCLUSIONS: For patients with newly diagnosed DIPG, a hypofractionation regimen, given over 3 to 4 weeks, offers equal overall survival with less treatment burden compared with a conventional regimen of 6 weeks.


Subject(s)
Brain Stem Neoplasms/radiotherapy , Glioma/radiotherapy , Pons , Adolescent , Brain Stem Neoplasms/mortality , Brain Stem Neoplasms/pathology , Child , Child, Preschool , Cohort Studies , Dose Fractionation, Radiation , Female , Glioma/mortality , Glioma/pathology , Humans , Male , Matched-Pair Analysis , Photons/therapeutic use , Pons/pathology , Statistics, Nonparametric , Survival Rate
4.
Radiother Oncol ; 102(2): 219-24, 2012 Feb.
Article in English | MEDLINE | ID: mdl-21864922

ABSTRACT

PURPOSE: To determine local control, late toxicity and metastatic free survival (MFS) of patients treated with fractionated stereotactic radiation therapy (fSRT) for uveal melanoma (UM). METHODS AND MATERIALS: Between 1999 and 2007, 102 UM patients were included in a prospective study of a single institution (median follow-up (FU) 32 months; median tumor thickness 6 mm); five fractions of 10 Gy were given. Primary endpoints were local tumor control and late toxicity (including visual outcome and eye preservation). Secondary endpoint was MFS. RESULTS: Local tumor control was achieved in 96% of the patients. Fifteen enucleations were performed, 2-85 months after radiation. Four eyes were enucleated because of local tumor progression. Nine patients developed grade 3 or 4 neovascular glaucoma (NVG), 19 developed severe retinopathy, 13 developed opticoneuropathy grade 3 or 4, 10 developed cataract grade 3, and 10 patients suffered from keratitis sicca. Best corrected visual acuity (BCVA) decreased from a mean of 0.26 at diagnosis to 0.16, 3 months after radiation and it gradually declined to 0.03, 4 years after therapy. The 5-year actuarial MFS was 75% (95% CIs: 62-84%). CONCLUSIONS: fSRT is an effective treatment modality for uveal melanoma with a good local control. With that, fSRT is a serious eye sparing treatment modality. However, our FU is relatively short. Also, the number of secondary enucleations is substantial, mainly caused by NVG.


Subject(s)
Melanoma/radiotherapy , Uveal Neoplasms/radiotherapy , Adult , Aged , Aged, 80 and over , Dose Fractionation, Radiation , Eye Enucleation , Female , Humans , Logistic Models , Male , Melanoma/pathology , Melanoma/surgery , Middle Aged , Neoplasm Staging , Prospective Studies , Radiotherapy Dosage , Stereotaxic Techniques , Survival Rate , Treatment Outcome , Uveal Neoplasms/pathology , Uveal Neoplasms/surgery
5.
Int J Radiat Oncol Biol Phys ; 82(1): 159-66, 2012 Jan 01.
Article in English | MEDLINE | ID: mdl-21183292

ABSTRACT

PURPOSE: To compare pathology macroscopic tumor dimensions with magnetic resonance imaging (MRI) measurements and to establish the microscopic tumor extension of colorectal liver metastases. METHODS AND MATERIALS: In a prospective pilot study we included patients with colorectal liver metastases planned for surgery and eligible for MRI. A liver MRI was performed within 48 hours before surgery. Directly after surgery, an MRI of the specimen was acquired to measure the degree of tumor shrinkage. The specimen was fixed in formalin for 48 hours, and another MRI was performed to assess the specimen/tumor shrinkage. All MRI sequences were imported into our radiotherapy treatment planning system, where the tumor and the specimen were delineated. For the macroscopic pathology analyses, photographs of the sliced specimens were used to delineate and reconstruct the tumor and the specimen volumes. Microscopic pathology analyses were conducted to assess the infiltration depth of tumor cell nests. RESULTS: Between February 2009 and January 2010 we included 13 patients for analysis with 21 colorectal liver metastases. Specimen and tumor shrinkage after resection and fixation was negligible. The best tumor volume correlations between MRI and pathology were found for T1-weighted (w) echo gradient sequence (r(s) = 0.99, slope = 1.06), and the T2-w fast spin echo (FSE) single-shot sequence (r(s) = 0.99, slope = 1.08), followed by the T2-w FSE fat saturation sequence (r(s) = 0.99, slope = 1.23), and the T1-w gadolinium-enhanced sequence (r(s) = 0.98, slope = 1.24). We observed 39 tumor cell nests beyond the tumor border in 12 metastases. Microscopic extension was found between 0.2 and 10 mm from the main tumor, with 90% of the cases within 6 mm. CONCLUSIONS: MRI tumor dimensions showed a good agreement with the macroscopic pathology suggesting that MRI can be used for accurate tumor delineation. However, microscopic extensions found beyond the tumor border indicate that caution is needed in selecting appropriate tumor margins.


Subject(s)
Colorectal Neoplasms , Liver Neoplasms/pathology , Liver Neoplasms/secondary , Magnetic Resonance Imaging/methods , Tumor Burden , Aged , Aged, 80 and over , Contrast Media , Female , Gadolinium DTPA , Humans , Liver/pathology , Liver Neoplasms/surgery , Male , Middle Aged , Pilot Projects , Prospective Studies , Radiosurgery , Radiotherapy Planning, Computer-Assisted , Regression Analysis , Remission Induction/methods , Statistics, Nonparametric , Tissue Fixation
6.
J Neurooncol ; 101(2): 237-45, 2011 Jan.
Article in English | MEDLINE | ID: mdl-20526795

ABSTRACT

The aim of the present study is to determine and compare initial treatment costs of microsurgery, linear accelerator (LINAC) radiosurgery, and gamma knife radiosurgery in meningioma patients. Additionally, the follow-up costs in the first year after initial treatment were assessed. Cost analyses were performed at two neurosurgical departments in The Netherlands from the healthcare providers' perspective. A total of 59 patients were included, of whom 18 underwent microsurgery, 15 underwent LINAC radiosurgery, and 26 underwent gamma knife radiosurgery. A standardized microcosting methodology was employed to ensure that the identified cost differences would reflect only actual cost differences. Initial treatment costs, using equipment costs per fraction, were 12,288 for microsurgery, 1,547 for LINAC radiosurgery, and 2,412 for gamma knife radiosurgery. Higher initial treatment costs for microsurgery were predominantly due to inpatient stay (5,321) and indirect costs (4,350). LINAC and gamma knife radiosurgery were equally expensive when equipment was valued per treatment (2,198 and 2,412, respectively). Follow-up costs were slightly, but not significantly, higher for microsurgery compared with LINAC and gamma knife radiosurgery. Even though initial treatment costs were over five times higher for microsurgery compared with both radiosurgical treatments, our study gives indications that the relative cost difference may decrease when follow-up costs occurring during the first year after initial treatment are incorporated. This reinforces the need to consider follow-up costs after initial treatment when examining the relative costs of alternative treatments.


Subject(s)
Meningeal Neoplasms/economics , Meningioma/economics , Microsurgery/economics , Particle Accelerators/economics , Radiosurgery/economics , Adult , Aged , Costs and Cost Analysis , Female , Follow-Up Studies , Humans , Male , Meningeal Neoplasms/surgery , Meningioma/surgery , Microsurgery/methods , Middle Aged , Radiosurgery/methods , Retrospective Studies , Treatment Outcome
8.
Br J Ophthalmol ; 94(5): 564-8, 2010 May.
Article in English | MEDLINE | ID: mdl-20447964

ABSTRACT

BACKGROUND/AIMS To report the outcome of primary radiotherapy in patients with progressive optic nerve sheath meningioma (ONSM). METHODS The clinical records of all patients were reviewed in a retrospective, observational, multicentre study. RESULTS Thirty-four consecutive patients were included. Twenty-six women and eight men received conventional or stereotactic fractionated radiotherapy, and were followed for a median 58 (range 51-156) months. Fourteen eyes (41%) showed improved visual acuity of at least two lines on the Snellen chart. In 17 (50%) eyes, the vision stabilised, while deterioration was noted in three eyes (9%). The visual outcome was not associated with age at the time of radiotherapy (p=0.83), sex (p=0.43), visual acuity at the time of presentation (p=0.22) or type of radiotherapy (p=0.35). Optic disc swelling was associated with improved visual acuity (p<0.01) and 4/11 patients with optic atrophy also showed improvement. Long-term complications were dry eyes in five patients, cataracts in three, and mild radiation retinopathy in four. CONCLUSION Primary radiotherapy for patients with ONSM is associated with long-term improvement of visual acuity and few adverse effects.


Subject(s)
Meningioma/radiotherapy , Optic Nerve Neoplasms/radiotherapy , Adolescent , Adult , Aged , Child , Disease Progression , Dry Eye Syndromes/etiology , Female , Follow-Up Studies , Humans , Male , Meningioma/complications , Middle Aged , Optic Nerve Neoplasms/complications , Prognosis , Radiation Injuries/etiology , Retinal Diseases/etiology , Retrospective Studies , Sex Distribution , Treatment Outcome , Vision Disorders/etiology , Vision Disorders/physiopathology , Visual Acuity , Visual Fields
9.
Radiat Oncol ; 5: 21, 2010 Mar 15.
Article in English | MEDLINE | ID: mdl-20230613

ABSTRACT

PURPOSE: To determine the variation in target delineation of nasopharyngeal carcinoma and the impact of measures to minimize this variation. MATERIALS AND METHODS: For ten nasopharyngeal cancer patients, ten observers each delineated the Clinical Target Volume (CTV) and the CTV elective. After 3D analysis of the delineated volumes, a second delineation was performed. This implied improved delineation instructions, a combined delineation on CT and co-registered MRI, forced use of sagittal reconstructions, and an on-line anatomical atlas. RESULTS: Both for the CTV and the CTV elective delineations, the 3D SD decreased from Phase 1 to Phase 2, from 4.4 to 3.3 mm for the CTV and from 5.9 to 4.9 mm for the elective. There was an increase agreement, where the observers intended to delineate the same structure, from 36 to 64 surface % (p = 0.003) for the CTV and from 17 to 59% (p = 0.004) for the elective. The largest variations were at the caudal border of the delineations but these were smaller when an observer utilized the sagittal window. Hence, the use of sagittal side windows was enforced in the second phase and resulted in a decreased standard deviation for this area from 7.7 to 3.3 mm (p = 0.001) for the CTV and 7.9 to 5.6 mm (p = 0.03) for the CTV elective. DISCUSSION: Attempts to decrease the variation need to be tailored to the specific causes of the variation. Use of delineation instructions multimodality imaging, the use of sagittal windows and an on-line atlas result in a higher agreement on the intended target.


Subject(s)
Magnetic Resonance Imaging , Nasopharyngeal Neoplasms/pathology , Nasopharyngeal Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Tomography, X-Ray Computed , Humans , Image Interpretation, Computer-Assisted , Imaging, Three-Dimensional , Nasopharyngeal Neoplasms/epidemiology , Observer Variation , Radiotherapy, Conformal
10.
Int J Radiat Oncol Biol Phys ; 75(4): 1201-8, 2009 Nov 15.
Article in English | MEDLINE | ID: mdl-19386435

ABSTRACT

PURPOSE: To assess day-to-day differences between planned and delivered target volume (TV) and organ-at-risk (OAR) dose distributions in liver stereotactic body radiation therapy (SBRT), and to investigate the dosimetric impact of setup corrections. METHODS AND MATERIALS: For 14 patients previously treated with SBRT, the planning CT scan and three treatment scans (one for each fraction) were included in this study. For each treatment scan, two dose distributions were calculated: one using the planned setup for the body frame (no correction), and one using the clinically applied (corrected) setup derived from measured tumor displacements. Per scan, the two dose distributions were mutually compared, and the clinically delivered distribution was compared with planning. Doses were recalculated in equivalent 2-Gy fraction doses. Statistical analysis was performed with the linear mixed model. RESULTS: With setup corrections, the mean loss in TV coverage relative to planning was 1.7%, compared with 6.8% without corrections. For calculated equivalent uniform doses, these figures were 2.3% and 15.5%, respectively. As for the TV, mean deviations of delivered OAR doses from planning were small (between -0.4 and +0.3 Gy), but the spread was much larger for the OARs. In contrast to the TV, the mean impact of setup corrections on realized OAR doses was close to zero, with large positive and negative exceptions. CONCLUSIONS: Daily correction of the treatment setup is required to obtain adequate TV coverage. Because of day-to-day patient anatomy changes, large deviations in OAR doses from planning did occur. On average, setup corrections had no impact on these doses. Development of new procedures for image guidance and adaptive protocols is warranted.


Subject(s)
Liver Neoplasms/diagnostic imaging , Liver Neoplasms/surgery , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , Adult , Aged , Aged, 80 and over , Duodenum/radiation effects , Female , Humans , Linear Models , Liver Neoplasms/pathology , Liver Neoplasms/secondary , Male , Middle Aged , Radiation Injuries/prevention & control , Radiotherapy Dosage , Stomach/radiation effects , Tomography, X-Ray Computed , Tumor Burden
11.
Int J Radiat Oncol Biol Phys ; 74(2): 497-502, 2009 Jun 01.
Article in English | MEDLINE | ID: mdl-18963540

ABSTRACT

PURPOSE: To find a dose-volume effect for inhomogeneous irradiated lacrimal glands. METHODS AND MATERIALS: Between 1999 and 2006, 72 patients (42 men and 30 women) were treated with fractionated stereotactic radiotherapy in a prospective, nonrandomized clinical trial (median follow-up, 32 months). A total dose of 50 Gy was given on 5 consecutive days. The mean of all Schirmer test results obtained > or =6 months after treatment was correlated with the radiation dose delivered to the lacrimal gland. Also, the appearance of dry eye syndrome (DES) was related to the lacrimal gland dose distribution. RESULTS: Of the 72 patients, 17 developed a late Schirmer value <10 mm; 9 patients developed DES. A statistically significant relationship was found between the received median dose in the lacrimal gland vs. reduced tear production (p = 0.000) and vs. the appearance of DES (p = 0.003), respectively. A median dose of 7 Gy/fraction to the lacrimal gland caused a 50% risk of low Schirmer results. A median dose of 10 Gy resulted in a 50% probability of DES. CONCLUSION: We found a clear dose-volume relationship for irradiated lacrimal glands with regard to reduced tear production and the appearance of DES.


Subject(s)
Dry Eye Syndromes/etiology , Lacrimal Apparatus/radiation effects , Melanoma/surgery , Radiation Tolerance , Radiosurgery/adverse effects , Uveal Neoplasms/surgery , Adult , Aged , Aged, 80 and over , Dose-Response Relationship, Radiation , Female , Humans , Male , Melanoma/mortality , Middle Aged , Prospective Studies , Regression Analysis , Tears/metabolism , Uveal Neoplasms/mortality
12.
Environ Manage ; 42(5): 789-802, 2008 Nov.
Article in English | MEDLINE | ID: mdl-18704561

ABSTRACT

Agricultural nonpoint source pollution remains a persistent environmental problem, despite the large amount of money that has been spent on its abatement. At local scales, agricultural best management practices (BMPs) have been shown to be effective at reducing nutrient and sediment inputs to surface waters. However, these effects have rarely been found to act in concert to produce measurable, broad-scale improvements in water quality. We investigated potential causes for this failure through an effort to develop recommendations for the use of riparian buffers in addressing nonpoint source pollution in Wisconsin. We used frequency distributions of phosphorus pollution at two spatial scales (watershed and field), along with typical stream phosphorus (P) concentration variability, to simulate benefit/cost curves for four approaches to geographically allocating conservation effort. The approaches differ in two ways: (1) whether effort is aggregated within certain watersheds or distributed without regard to watershed boundaries (dispersed), and (2) whether effort is targeted toward the most highly P-polluting fields or is distributed randomly with regard to field-scale P pollution levels. In realistic implementation scenarios, the aggregated and targeted approach most efficiently improves water quality. For example, with effort on only 10% of a model landscape, 26% of the total P load is retained and 25% of watersheds significantly improve. Our results indicate that agricultural conservation can be more efficient if it accounts for the uneven spatial distribution of potential pollution sources and the cumulative aspects of environmental benefits.


Subject(s)
Agriculture/methods , Conservation of Natural Resources/methods , Environmental Monitoring , Water Pollution/prevention & control , Water Supply/analysis , Geographic Information Systems , Geologic Sediments/analysis , Phosphorus/analysis , Water Pollutants, Chemical/analysis , Water Supply/standards , Wisconsin
13.
Int J Radiat Oncol Biol Phys ; 70(5): 1403-7, 2008 Apr 01.
Article in English | MEDLINE | ID: mdl-17980511

ABSTRACT

PURPOSE: To derive guidelines for the need to use positron emission tomography (PET) for delineation of the primary tumor (PT) according to its anatomical location in the lung. METHODS AND MATERIALS: In 22 patients with non-small-cell lung cancer, thoracic X-ray computed tomography (CT) and PET were performed. Eleven radiation oncologists delineated the PT on the CT and on the CT-PET registered scans. The PTs were classified into two groups. In Group I patients, the PT was surrounded by lung or visceral pleura, without venous invasion, without extension to chest wall or the mediastinum over more than one quarter of its surface. In Group II patients, the PT invaded the hilar region, heart, great vessels, pericardium, mediastinum over more than one quarter of its surface and/or associated with atelectasis. A comparison of interobserver variability for each group was performed and expressed as a local standard deviation. RESULTS: The comparison of delineations showed a good reproducibility for Group I, with an average SD of 0.4 cm on CT and an average SD of 0.3 cm on CT-PET (p = 0.1628). There was also a significant improvement with CT-PET for Group II, with an average SD of 1.3 cm on CT and SD of 0.4 cm on CT-PET (p = 0.0003). The improvement was mainly located at the atelectasis/tumor interface. At the tumor/lung and tumor/hilum interfaces, the observer variation was similar with both modalities. CONCLUSIONS: Using PET for PT delineation is mandatory to decrease interobserver variability in the hilar region, heart, great vessels, pericardium, mediastinum, and/or the region associated with atelectasis; however it is not essential for delineation of PT surrounded by lung or visceral pleura, without venous invasion or extension to the chest wall.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Positron-Emission Tomography/methods , Tomography, X-Ray Computed/methods , Aged , Aged, 80 and over , Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Carcinoma, Non-Small-Cell Lung/pathology , Female , Humans , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/pathology , Male , Middle Aged , Neoplasm Invasiveness , Observer Variation , Pulmonary Atelectasis/diagnostic imaging , Reproducibility of Results
14.
Int J Radiat Oncol Biol Phys ; 70(5): 1447-52, 2008 Apr 01.
Article in English | MEDLINE | ID: mdl-17996394

ABSTRACT

PURPOSE: Stereotactic body radiation therapy (SBRT) provides a high local control rate for primary and metastatic liver tumors. The aim of this study is to assess the impact of this treatment on the patient's quality of life. This is the first report of quality of life associated with liver SBRT. METHODS AND MATERIALS: From October 2002 to March 2007, a total of 28 patients not suitable for other local treatments and with Karnofsky performance status of at least 80% were entered in a Phase I-II study of SBRT for liver tumors. Quality of life was a secondary end point. Two generic quality of life instruments were investigated, EuroQol-5D (EQ-5D) and EuroQoL-Visual Analogue Scale (EQ-5D VAS), in addition to a disease-specific questionnaire, the European Organization for Research and Treatment of Cancer Core Quality of Life Questionnaire (EORTC QLQ C-30). Points of measurement were directly before and 1, 3, and 6 months after treatment. Mean scores and SDs were calculated. Statistical analysis was performed using paired-samples t-test and Student t-test. RESULTS: The calculated EQ-5D index, EQ-5D VAS and QLQ C-30 global health status showed that mean quality of life of the patient group was not significantly influenced by treatment with SBRT; if anything, a tendency toward improvement was found. CONCLUSIONS: Stereotactic body radiation therapy combines a high local control rate, by delivering a high dose per fraction, with no significant change in quality of life. Multicenter studies including larger numbers of patients are recommended and under development.


Subject(s)
Carcinoma, Hepatocellular/radiotherapy , Liver Neoplasms/radiotherapy , Quality of Life , Stereotaxic Techniques , Adult , Aged , Aged, 80 and over , Dose Fractionation, Radiation , Female , Follow-Up Studies , Humans , Karnofsky Performance Status , Liver Neoplasms/secondary , Male , Middle Aged , Prospective Studies , Surveys and Questionnaires/standards
15.
Radiother Oncol ; 83(1): 42-8, 2007 Apr.
Article in English | MEDLINE | ID: mdl-17343940

ABSTRACT

PURPOSE: To evaluate the image quality of retrospectively attenuation corrected Positron Emission Tomography (PET) scans used for gross tumor volume (GTV) delineation in lung cancer patients. MATERIALS AND METHODS: Data of 13 lymph node positive lung cancer patients were acquired on separate CT and PET scanners under free breathing conditions (for radiotherapy planning). First we determined a protocol for CT/PET registration. Second, we compared the image quality of attenuation-corrected PET images using positron transmission images and CT images, in terms of signal-to-noise ratio (SNR) and lesion-to-background ratio (contrast). RESULTS: The largest differences between manual and automatic CT/PET registration were found in the anterior-posterior direction with a mean of 1.8 mm (SD 1.0 mm). Differences in rotations were always smaller than 1.0 degrees . The attenuation-corrected images using CT showed a larger SNR (mean 30%, SD 17%) and larger contrast (mean 14.0%, SD 8.5%) compared to attenuation-corrected images using positron transmission. For lymph nodes, the mean contrast was 16% (SD 6.4%) larger. CONCLUSIONS: This study demonstrated that attenuation correction based on CT provides a better image quality for GTV delineation than when using positron transmission for attenuation correction. Retrospective attenuation correction of PET scans based on registered CT is a good alternative for a dedicated PET/CT scanner if a free-breathing CT is available, e.g., for radiotherapy planning, and allows the use of CT with diagnostic quality for attenuation correction.


Subject(s)
Image Processing, Computer-Assisted , Lung Neoplasms/radiotherapy , Positron-Emission Tomography , Tomography, X-Ray Computed , Aged , Female , Humans , Image Enhancement , Lung Neoplasms/diagnostic imaging , Lymphatic Metastasis , Male , Middle Aged , Respiration
16.
Int J Radiat Oncol Biol Phys ; 64(2): 435-48, 2006 Feb 01.
Article in English | MEDLINE | ID: mdl-16198064

ABSTRACT

PURPOSE: Target delineation using only CT information introduces large geometric uncertainties in radiotherapy for lung cancer. Therefore, a reduction of the delineation variability is needed. The impact of including a matched CT scan with 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) and adaptation of the delineation protocol and software on target delineation in lung cancer was evaluated in an extensive multi-institutional setting and compared with the delineations using CT only. METHODS AND MATERIALS: The study was separated into two phases. For the first phase, 11 radiation oncologists (observers) delineated the gross tumor volume (GTV), including the pathologic lymph nodes of 22 lung cancer patients (Stages I-IIIB) on CT only. For the second phase (1 year later), the same radiation oncologists delineated the GTV of the same 22 patients on a matched CT-FDG-PET scan using an adapted delineation protocol and software (according to the results of the first phase). All delineated volumes were analyzed in detail. The observer variation was computed in three dimensions by measuring the distance between the median GTV surface and each individual GTV. The variation in distance of all radiation oncologists was expressed as a standard deviation. The observer variation was evaluated for anatomic regions (lung, mediastinum, chest wall, atelectasis, and lymph nodes) and interpretation regions (agreement and disagreement; i.e., >80% vs. <80% of the radiation oncologists delineated the same structure, respectively). All radiation oncologist-computer interactions were recorded and analyzed with a tool called "Big Brother." RESULTS: The overall three-dimensional observer variation was reduced from 1.0 cm (SD) for the first phase (CT only) to 0.4 cm (SD) for the second phase (matched CT-FDG-PET). The largest reduction in the observer variation was seen in the atelectasis region (SD 1.9 cm reduced to 0.5 cm). The mean ratio between the common and encompassing volume was 0.17 and 0.29 for the first and second phases, respectively. For the first phase, the common volume was 0 in 4 patients (i.e., no common point for all GTVs). In the second phase, the common volume was always >0. For all anatomic regions, the interpretation differences among the radiation oncologists were reduced. The amount of disagreement was 45% and 18% for the first and second phase, respectively. Furthermore, the mean delineation time (12 vs. 16 min, p<0.001) and mean number of corrections (25 vs. 39, p<0.001) were reduced in the second phase compared with the first phase. CONCLUSION: For high-precision radiotherapy, the delineation of lung target volumes using only CT introduces too great a variability among radiation oncologists. Implementing matched CT-FDG-PET and adapted delineation protocol and software reduced observer variation in lung cancer delineation significantly with respect to CT only. However, the remaining observer variation was still large compared with other geometric uncertainties (setup variation and organ motion).


Subject(s)
Lung Neoplasms/diagnostic imaging , Observer Variation , Tomography, Emission-Computed/methods , Tomography, X-Ray Computed/methods , Aged , Aged, 80 and over , Diagnosis, Computer-Assisted , Female , Fluorodeoxyglucose F18/therapeutic use , Humans , Lung/diagnostic imaging , Lymph Nodes/diagnostic imaging , Male , Mediastinum/diagnostic imaging , Middle Aged , Radiopharmaceuticals/therapeutic use , Thoracic Wall/diagnostic imaging
17.
Radiother Oncol ; 77(2): 182-90, 2005 Nov.
Article in English | MEDLINE | ID: mdl-16256231

ABSTRACT

BACKGROUND AND PURPOSE: To evaluate the process of target volume delineation in lung cancer for optimization of imaging, delineation protocol and delineation software. PATIENTS AND METHODS: Eleven radiation oncologists (observers) from five different institutions delineated the Gross Tumor Volume (GTV) including positive lymph nodes of 22 lung cancer patients (stages I-IIIB) on CT only. All radiation oncologist-computer interactions were recorded with a tool called 'Big Brother'. For each radiation oncologist and patient the following issues were analyzed: delineation time, number of delineated points and corrections, zoom levels, level and window (L/W) settings, CT slice changes, use of side windows (coronal and sagittal) and software button use. RESULTS: The mean delineation time per GTV was 16 min (SD 10 min). The mean delineation time for lymph node positive patients was on average 3 min larger (P = 0.02) than for lymph node negative patients. Many corrections (55%) were due to L/W change (e.g. delineating in mediastinum L/W and then correcting in lung L/W). For the lymph node region, a relatively large number of corrections was found (3.7 corr/cm2), indicating that it was difficult to delineate lymph nodes. For the tumor-atelectasis region, a relative small number of corrections was found (1.0 corr/cm2), indicating that including or excluding atelectasis into the GTV was a clinical decision. Inappropriate use of L/W settings was frequently found (e.g. 46% of all delineated points in the tumor-lung region were delineated in mediastinum L/W settings). Despite a large observer variation in cranial and caudal direction of 0.72 cm (1 SD), the coronal and sagittal side windows were not used in 45 and 60% of the cases, respectively. For the more difficult cases, observer variation was smaller when the coronal and sagittal side windows were used. CONCLUSIONS: With the 'Big Brother' tool a method was developed to trace the delineation process. The differences between observers concerning the delineation style were large. This study led to recommendations on how to improve delineation accuracy by adapting the delineation protocol (guidelines for L/W use) and delineation software (double window with lung and mediastinum L/W settings at the same time, enforced use of coronal and sagittal views) and including FDG-PET information (lymph nodes and atelectasis).


Subject(s)
Carcinoma, Non-Small-Cell Lung/radiotherapy , Lung Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/instrumentation , Aged , Aged, 80 and over , Carcinoma, Non-Small-Cell Lung/pathology , Cohort Studies , Dose-Response Relationship, Radiation , Equipment Design , Equipment Safety , Evaluation Studies as Topic , Female , Humans , Lung Neoplasms/pathology , Male , Middle Aged , Neoplasm Staging , Observer Variation , Practice Patterns, Physicians' , Radiation Oncology/standards , Radiation Oncology/trends , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Risk Assessment , Sensitivity and Specificity , Tomography, X-Ray Computed , Treatment Outcome
18.
Int J Radiat Oncol Biol Phys ; 63(1): 116-22, 2005 Sep 01.
Article in English | MEDLINE | ID: mdl-16111579

ABSTRACT

PURPOSE: To study the effectiveness and acute side effects of fractionated stereotactic radiation therapy (fSRT) for uveal melanoma. METHODS AND MATERIALS: Between 1999 and 2003, 38 patients (21 male, 17 female) were included in a prospective, nonrandomized clinical trial (mean follow-up of 25 months). A total dose of 50 Gy was given in 5 consecutive days. A blinking light and a camera (to monitor the position of the diseased eye) were fixed to a noninvasive relocatable stereotactic frame. Primary end points were local control, best corrected visual acuity, and toxicity at 3, 6, 12, and 24 months, respectively. RESULTS: After 3 months (38 patients), the local control was 100%; after 12 months (32 patients) and 24 months (15 patients), no recurrences were seen. The best corrected visual acuity declined from a mean of 0.21 at diagnosis to 0.06 2 years after therapy. The acute side effects after 3 months were as follows: conjunctival symptoms (10), loss of lashes or hair (6), visual symptoms (5), fatigue (5), dry eye (1), cataract (1), and pain (4). One eye was enucleated at 2 months after fSRT. CONCLUSIONS: Preliminary results demonstrate that fSRT is an effective and safe treatment modality for uveal melanoma with an excellent local control and mild acute side effects. The follow-up should be prolonged to study both long-term local control and late toxicity.


Subject(s)
Melanoma/radiotherapy , Radiosurgery/methods , Uveal Neoplasms/radiotherapy , Dose Fractionation, Radiation , Female , Humans , Melanoma/mortality , Middle Aged , Prospective Studies , Radiosurgery/adverse effects , Retinal Detachment/therapy , Uveal Neoplasms/mortality , Visual Acuity/radiation effects
19.
Cancer ; 104(5): 1090-9, 2005 Sep 01.
Article in English | MEDLINE | ID: mdl-16015632

ABSTRACT

BACKGROUND: Aggressive fibromatosis (AF) is a soft tissue tumor and is rare in childhood, with high potential for local invasiveness and recurrence. General recommendations for the clinical management of pediatric patients with AF remain undetermined. METHODS: The authors retrospectively analyzed 13 children with AF who were diagnosed from 1987 until 2004 in the Erasmus MC-Sophia Children's Hospital, and a review of the pediatric literature was conducted. RESULTS: Two patients received preoperative chemotherapy with combined vincristine, actinomycin-D, and cyclophosphamide (VAC). All 13 patients underwent surgery. Three of six patients who underwent incomplete resection received adjuvant treatment, two patients received radiotherapy, and one patient received chemotherapy (VAC). The median follow-up was 3.9 years (range, 0.6-14.0 years). Three patients developed recurrent AF, including two recurrences after patients underwent incomplete resection without adjuvant treatment. Secondary resection was performed, which was incomplete in one patient who subsequently received chemotherapy (VAC). At the time of the current report, all 13 patients were in complete remission. Ten pediatric AF studies, including the current study, with a total of 187 patients were reviewed. Incomplete resection was the most important determinant for disease recurrence; in the authors' opinion, the role of adjuvant therapy needs to be studied further. CONCLUSIONS: Primary surgery with negative surgical margins was found to be the most successful primary treatment modality for children with AF. Positive margins after surgery indicated a high risk for disease recurrence. Multicenter, prospective (randomized) trials will be necessary to clarify the role of adjuvant treatment for patients with pediatric AF.


Subject(s)
Fibromatosis, Aggressive/surgery , Soft Tissue Neoplasms/surgery , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Male , Retrospective Studies
20.
Int J Radiat Oncol Biol Phys ; 62(3): 888-92, 2005 Jul 01.
Article in English | MEDLINE | ID: mdl-15936574

ABSTRACT

PURPOSE: We used four-dimensional multislice spiral computed tomography (MSCT) to determine respiratory lung-tumor motion and compared this strategy to common clinical practice in conformal radiotherapy treatment-planning imaging. METHODS AND MATERIALS: The entire lung volume of 10 consecutive patients with 14 lung metastases were scanned by a 16-slice MSCT. During the scans, patients were instructed to breathe through a spirometer that was connected to a laptop computer. For each patient, 10 stacks of 1.5-mm slices, equally distributed throughout the respiratory cycle, were reconstructed from the acquired MSCT data. The lung tumors were manually contoured in each data set. For each patient, the tumor-volume contours of all data sets were copied to 1 data set, which allowed determination of the volume that encompassed all 10 lung-tumor positions (i.e., the tumor-traversed volume [TTV]) during the respiratory cycle. The TTV was compared with the 10 tumor volumes contoured for each patient, to which an empiric respiratory-motion margin was added. The latter target volumes were designated internal-motion included tumor volume (IMITV). RESULTS: The TTV measurements were significantly smaller than the reference IMITV measurements (5.2 +/- 10.2 cm(3) and 10.1 +/- 13.7 cm(3), respectively). All 10 IMITVs for 2 of the 4 tumors in 1 subject completely encompassed the TTV. All 10 IMITVs for 3 tumors in 2 patients did not show overlap with up to 35% of the corresponding TTV. The 10 IMITVs for the remaining tumors either completely encompassed the corresponding TTV or did not show overlap with up to 26% of the corresponding TTV. CONCLUSIONS: We found that individualized determination of respiratory lung-tumor motion by four-dimensional respiratory-gated MSCT represents a better and simple strategy to incorporate periodic physiologic motion compared with a generalized approach. The former strategy can, therefore, improve common and state-of-the-art clinical practice in conformal radiotherapy.


Subject(s)
Lung Neoplasms/diagnostic imaging , Movement , Radiotherapy, Conformal , Respiration , Tomography, X-Ray Computed/methods , Aged , Female , Humans , Lung Neoplasms/radiotherapy , Lung Neoplasms/secondary , Male , Middle Aged