Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Article in English | MEDLINE | ID: mdl-21384724

ABSTRACT

For aviation, a suitable alternative for currently used in-flight anti-/de-icing technologies for today's aircrafts with metal structures and future aircrafts with replaced composite structures is necessary. Intense investigations performed at FZK have been together in collaboration with aircraft manufacturers to design and develop a new avionic microwave technology for monolithic composite structures.The full system integration has been evaluated for several airplanes considering the structural and efficiency demands. The concept of this MIDAS (MIcrowave De-icing Anti-icing System) technology as well their recent results will be presented. A full system integration has been tested and is visualized in the paper.

2.
Rofo ; 175(10): 1424-30, 2003 Oct.
Article in German | MEDLINE | ID: mdl-14556113

ABSTRACT

PURPOSE: To compare measurements of the real AT (femoral antetorsion) and CCD (caput-collum-diaphysis) angle by computed tomography (CT) and magnetic resonance imaging (MRI) of hip specimen using direct measurements as reference standard, and to show that measurement by MRI can replace CT measurements and may help avoiding X-ray exposition. MATERIALS AND METHODS: CT and MRI measurements were obtained on 25 in water-arrested macerated human femora. Postprocessing was done by 4 independent readers on a workstation using a dedicated 3D-software. Direct measurements of the real AT and the CCD angle were used as reference standard. The analysis included Student's t test for paired values, interobserver variability using intra-class correlation coefficients (ICC), maximum and middle divergence of the angles, and Bland-Altman plots. RESULTS: For determining AT and the CCD angle with CT and MRI, good correlation was found between the 4 readers and with measurements using the reference standard. ICCs were 0.97 and 0.90 for measuring AT and CCD angle with CT, and 0.95 and 0.71 for measurements with MRI, respectively. Mean divergence between CT measurements and those of the reference standard was 0.8 degrees for AT and 0.7 degrees for the CCD-angle. Mean divergence between MRI measurements and those of the reference standard was 0.3 degrees for AT and -0.4 degrees for the CCD-angle. Mean divergences between CT and MRI measurements of AT and CCD-angle were 0.5 degrees. Neither systematic errors nor dependences on the qualitative size of the reference data were evident in the divergences of measurements. CONCLUSION: Measurements of the real AT and CCD angle by CT and MR imaging revealed a good correlation with direct measurements of the femoral specimen and consequently can be recommended for clinical use. MRI measurements can replace CT measurements, avoiding X-ray exposure especially in young patients undergoing preoperative evaluation for hip dysplasia.


Subject(s)
Bone Malalignment/diagnosis , Femur/pathology , Magnetic Resonance Imaging/methods , Mathematical Computing , Tomography, X-Ray Computed/methods , Bone Malalignment/pathology , Femur Head/pathology , Femur Neck/pathology , Humans , Observer Variation , Phantoms, Imaging , Reference Standards , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...