Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Interv Cardiol ; 2020: 9602942, 2020.
Article in English | MEDLINE | ID: mdl-32934609

ABSTRACT

BACKGROUND: Percutaneous coronary intervention exposes patient and staff to ionizing radiation. Although staff only receive a small fraction of patient dose through scatter radiation, there are concerns about the potential health effects of repeated exposure. Minimizing both patient and occupational exposure is needed. OBJECTIVE: This article investigates patient and operator X-ray exposure over time in coronary intervention in relation to upgraded X-ray equipment, improved shielding, and enhanced operator awareness. MATERIALS AND METHODS: Data regarding irradiation time, patient dose, and patient characteristics were extracted from the Norwegian Registry for Invasive Cardiology (NORIC) for procedures performed from 2013 to mid-2019. Personal operator dosimetry records were provided by the Norwegian Radiation and Nuclear Safety Authority. Improved operator shielding and awareness measures were introduced in 2018. RESULTS: In the period 2013 through June 2019, 21499 procedures were recorded in our institution. Mean dose area product (DAP) for coronary angiography decreased 37% from 2981 µGy·m2 in 2013 to 1891 µGy·m2 in 2019 (p < 0.001). For coronary intervention, DAP decreased 39% from 8358 µGy·m2 to 5055 µGy·m2. Personal dosimetry data indicate a 70% reduction in operator dose per procedure in 2019 compared to 2013. The most pronounced reduction occurred after improved radiation protection measures were implemented in 2018 (-48%). CONCLUSIONS: This study shows a temporal trend towards considerable reduction in X-ray doses received by the patient and operator during cardiac catheterization. Upgraded X-ray equipment, improved shielding, and enhanced operator awareness are likely contributors to this development.


Subject(s)
Coronary Angiography , Percutaneous Coronary Intervention , Radiation Exposure/prevention & control , Radiologic Health/trends , Coronary Angiography/instrumentation , Coronary Angiography/methods , Coronary Angiography/standards , Humans , Occupational Exposure/prevention & control , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/methods , Percutaneous Coronary Intervention/standards
SELECTION OF CITATIONS
SEARCH DETAIL
...