Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Resuscitation ; 73(1): 54-61, 2007 Apr.
Article in English | MEDLINE | ID: mdl-17258853

ABSTRACT

BACKGROUND: Cardiopulmonary resuscitation (CPR) quality during actual cardiac arrest has been found to be deficient in several recent investigations. We hypothesized that real-time feedback during CPR would improve the performance of chest compressions and ventilations during in-hospital cardiac arrest. METHODS: An investigational monitor/defibrillator with CPR-sensing and feedback capabilities was used during in-hospital cardiac arrests from December 2004 to December 2005. Chest compression and ventilation characteristics were recorded and quantified for the first 5 min of resuscitation and compared to a baseline cohort of arrest episodes without feedback, from December 2002 to April 2004. RESULTS: Data from 55 resuscitation episodes in the baseline pre-intervention group were compared to 101 resuscitations in the feedback intervention group. There was a trend toward improvement in the mean values of CPR variables in the feedback group with a statistically significant narrowing of CPR variable distributions including chest compression rate (104+/-18 to 100+/-13 min(-1); test of means, p=0.16; test of variance, p=0.003) and ventilation rate (20+/-10 to 18+/-8 min(-1); test of means, p=0.12; test of variance, p=0.04). There were no statistically significant differences between the groups in either return of spontaneous circulation or survival to hospital discharge. CONCLUSIONS: Real-time CPR-sensing and feedback technology modestly improved the quality of CPR during in-hospital cardiac arrest, and may serve as a useful adjunct for rescuers during resuscitation efforts. However, feedback specifics should be optimized for maximal benefit and additional studies will be required to assess whether gains in CPR quality translate to improvements in survival.


Subject(s)
Cardiopulmonary Resuscitation/standards , Defibrillators , Feedback , Heart Arrest/therapy , Electric Countershock , Equipment Design , Female , Hospitalization , Humans , Male , Middle Aged , Quality Assurance, Health Care
2.
Circulation ; 111(4): 428-34, 2005 Feb 01.
Article in English | MEDLINE | ID: mdl-15687130

ABSTRACT

BACKGROUND: Recent data highlight a vital link between well-performed cardiopulmonary resuscitation (CPR) and survival after cardiac arrest; however, the quality of CPR as actually performed by trained healthcare providers is largely unknown. We sought to measure in-hospital chest compression rates and to determine compliance with published international guidelines. METHODS AND RESULTS: We developed and validated a handheld recording device to measure chest compression rate as a surrogate for CPR quality. A prospective observational study of adult cardiac arrests was performed at 3 hospitals from April 2002 to October 2003. Resuscitations were witnessed by trained observers using a customized personal digital assistant programmed to store the exact time of each chest compression, allowing offline calculation of compression rates at serial time points. In 97 arrests, data from 813 minutes during which chest compressions were delivered were analyzed in 30-second time segments. In 36.9% of the total number of segments, compression rates were <80 compressions per minute (cpm), and 21.7% had rates <70 cpm. Higher chest compression rates were significantly correlated with initial return of spontaneous circulation (mean chest compression rates for initial survivors and nonsurvivors, 90+/-17 and 79+/-18 cpm, respectively; P=0.0033). CONCLUSIONS: In-hospital chest compression rates were below published resuscitation recommendations, and suboptimal compression rates in our study correlated with poor return of spontaneous circulation. CPR quality is likely a critical determinant of survival after cardiac arrest, suggesting the need for routine measurement, monitoring, and feedback systems during actual resuscitation.


Subject(s)
Cardiopulmonary Resuscitation/methods , Heart Arrest/therapy , Aged , Aged, 80 and over , Cardiopulmonary Resuscitation/standards , Computers, Handheld , Female , Heart Arrest/mortality , Humans , Inpatients , Male , Manometry/instrumentation , Middle Aged , Practice Guidelines as Topic , Prospective Studies , Survival Analysis , Time Factors , Treatment Outcome
3.
JAMA ; 293(3): 305-10, 2005 Jan 19.
Article in English | MEDLINE | ID: mdl-15657323

ABSTRACT

CONTEXT: The survival benefit of well-performed cardiopulmonary resuscitation (CPR) is well-documented, but little objective data exist regarding actual CPR quality during cardiac arrest. Recent studies have challenged the notion that CPR is uniformly performed according to established international guidelines. OBJECTIVES: To measure multiple parameters of in-hospital CPR quality and to determine compliance with published American Heart Association and international guidelines. DESIGN AND SETTING: A prospective observational study of 67 patients who experienced in-hospital cardiac arrest at the University of Chicago Hospitals, Chicago, Ill, between December 11, 2002, and April 5, 2004. Using a monitor/defibrillator with novel additional sensing capabilities, the parameters of CPR quality including chest compression rate, compression depth, ventilation rate, and the fraction of arrest time without chest compressions (no-flow fraction) were recorded. MAIN OUTCOME MEASURE: Adherence to American Heart Association and international CPR guidelines. RESULTS: Analysis of the first 5 minutes of each resuscitation by 30-second segments revealed that chest compression rates were less than 90/min in 28.1% of segments. Compression depth was too shallow (defined as <38 mm) for 37.4% of compressions. Ventilation rates were high, with 60.9% of segments containing a rate of more than 20/min. Additionally, the mean (SD) no-flow fraction was 0.24 (0.18). A 10-second pause each minute of arrest would yield a no-flow fraction of 0.17. A total of 27 patients (40.3%) achieved return of spontaneous circulation and 7 (10.4%) were discharged from the hospital. CONCLUSIONS: In this study of in-hospital cardiac arrest, the quality of multiple parameters of CPR was inconsistent and often did not meet published guideline recommendations, even when performed by well-trained hospital staff. The importance of high-quality CPR suggests the need for rescuer feedback and monitoring of CPR quality during resuscitation efforts.


Subject(s)
Cardiopulmonary Resuscitation/standards , Guideline Adherence/statistics & numerical data , Heart Arrest/therapy , Adult , Aged , Aged, 80 and over , Cardiopulmonary Resuscitation/methods , Chicago , Female , Hospitalization , Hospitals, University/standards , Humans , Male , Middle Aged , Practice Guidelines as Topic , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...