1.
Rev Sci Instrum ; 85(9): 093101, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25273701

ABSTRACT

Non-mode-matched cavity-enhanced absorption spectrometry (e.g., cavity ringdown spectroscopy and integrated cavity output spectroscopy) is commonly used for the ultrasensitive detection of trace gases. These techniques are attractive for their simplicity and robustness, but their performance may be limited by the reflection of light from the front mirror and the resulting low optical transmission. Although this low transmitted power can sometimes be overcome with higher power lasers and lower noise detectors (e.g., in the near-infrared), many regimes exist where the available light intensity or photodetector sensitivity limits instrument performance (e.g., in the mid-infrared). In this article, we describe a method of repeatedly re-injecting light reflected off the front mirror of the optical cavity to boost the cavity's circulating power and deliver more light to the photodetector and thus increase the signal-to-noise ratio of the absorption measurement. We model and experimentally demonstrate the method's performance using off-axis cavity ringdown spectroscopy (OA-CRDS) with a broadly tunable external cavity quantum cascade laser. The power coupled through the cavity to the detector is increased by a factor of 22.5. The cavity loss is measured with a precision of 2 × 10(-10) cm(-1)/√Hz; an increase of 12 times over the standard off-axis configuration without reinjection and comparable to the best reported sensitivities in the mid-infrared. Finally, the re-injected CRDS system is used to measure the spectrum of several volatile organic compounds, demonstrating the improved ability to resolve weakly absorbing spectroscopic features.


Subject(s)
Absorption, Physicochemical , Optical Devices , Spectrum Analysis/instrumentation , Metals , Volatile Organic Compounds/analysis , Volatile Organic Compounds/chemistry
2.
Appl Opt ; 44(31): 6712-7, 2005 Nov 01.
Article in English | MEDLINE | ID: mdl-16270560

ABSTRACT

An autonomous instrument based on off-axis integrated cavity output spectroscopy has been developed and successfully deployed for measurements of carbon monoxide in the troposphere and tropopause onboard a NASA DC-8 aircraft. The instrument (Carbon Monoxide Gas Analyzer) consists of a measurement cell comprised of two high-reflectivity mirrors, a continuous-wave quantum-cascade laser, gas sampling system, control and data-acquisition electronics, and data-analysis software. CO measurements were determined from high-resolution CO absorption line shapes obtained by tuning the laser wavelength over the R(7) transition of the fundamental vibration band near 2172.8 cm(-1). The instrument reports CO mixing ratio (mole fraction) at a 1-Hz rate based on measured absorption, gas temperature, and pressure using Beer's Law. During several flights in May-June 2004 and January 2005 that reached altitudes of 41,000 ft (12.5 km), the instrument recorded CO values with a precision of 0.2 ppbv (1-s averaging time) and an accuracy limited by the reference CO gas cylinder (uncertainty < 1.0%). Despite moderate turbulence and measurements of particulate-laden airflows, the instrument operated consistently and did not require any maintenance, mirror cleaning, or optical realignment during the flights.

3.
Opt Lett ; 29(10): 1066-8, 2004 May 15.
Article in English | MEDLINE | ID: mdl-15181987

ABSTRACT

A method for the practical determination of the absolute concentration of single (a1delta(g)) oxygen is discussed. The method is based on sensitive off-axis integrated-cavity-output spectroscopy (ICOS). Off-axis ICOS allows narrowband, continuous-wave lasers to be used in conjunction with optical cavities to record sensitive absorption measurements. The details of the method as well as spectroscopic data confirming the first observation of the (1, 0) band of the b1sigma(g)(+) - a1delta(g) Noxon system are presented. The absolute transition probabilities for the b1sigma(g)(+) - a1delta(g) Noxon system, which are not known precisely from experiments, are determined by quantum chemistry theory.

4.
Opt Lett ; 27(21): 1878-80, 2002 Nov 01.
Article in English | MEDLINE | ID: mdl-18033388

ABSTRACT

Cavity-enhanced methods have been extended to fiber optics by use of fiber Bragg gratings (FBGs) as reflectors. High-finesse fiber cavities were fabricated from FBGs made in both germanium/boron-co-doped photosensitive fiber and hydrogen-loaded Corning SMF-28 fiber. Optical losses in these cavities were determined from the measured Fabry-Perot transmission spectra and cavity ring-down spectroscopy. For a 10-m-long single-mode fiber cavity, ring-down times in excess of 2 ms were observed at 1563.6 nm, and individual laser pulses were resolved. An evanescent-wave access block was produced within a fiber cavity, and an enhanced sensitivity to optical loss was observed as the external medium's refractive index was altered.