Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 73
Filter
1.
ACS Nano ; 17(15): 14586-14603, 2023 08 08.
Article in English | MEDLINE | ID: mdl-37463491

ABSTRACT

It has been shown that inhalation exposure to copper oxide nanoparticles (CuO NPs) results in pulmonary inflammation. However, immunomodulatory consequences after CuO NP inhalation exposure have been less explored. We tested the effect of CuO NP aerosols on immune responses in healthy, house dust mite (HDM) asthmatic, or allergen immunotherapy (AIT)-treated asthmatic mice (BALB/c, females). The AIT consisted of a vaccine comprising HDM allergens and CpG-loaded nanoparticles (CpG NPs). AIT treatment involved mice being immunized (via subcutaneous (sc) injection; 2 doses) while concomitantly being exposed to CuO NP aerosols (over a 2 week period), starting on the day of the first vaccination. Mice were then sensitized twice by sc injection and subsequently challenged with HDM extract 10 times by intranasal instillation. The asthmatic model followed the same timeline except that no immunizations were administered. All mice were necropsied 24 h after the end of the HDM challenge. CuO NP-exposed healthy mice showed a significant decrease in TH1 and TH2 cells, and an elevation in T-bet+ Treg cells, even 40 days after the last exposure to CuO NPs. Similarly, the CuO NP-exposed HDM asthma model demonstrated decreased TH2 responses and increased T-bet+ Treg cells. Conversely, CuO NP inhalation exposure to AIT-treated asthmatic mice resulted in an increase in TH2 cells. In conclusion, immunomodulatory effects of inhalation exposure to CuO NPs are dependent on immune conditions prior to exposure.


Subject(s)
Asthma , Nanoparticles , Female , Mice , Animals , Copper , Inhalation Exposure , Asthma/chemically induced , Asthma/therapy , Pyroglyphidae , Immunity , Oxides
2.
J Occup Environ Hyg ; 20(9): 390-400, 2023 09.
Article in English | MEDLINE | ID: mdl-37339509

ABSTRACT

Despite efforts to apply administrative and engineering controls to minimize worker exposure to aerosols, filtering facepiece respirators (FFRs) continue to be an important form of personal protective equipment in hard-to-control settings such as healthcare, agriculture, and construction. Optimizing the performance of FFRs can be advanced with the use of mathematical models that incorporate the forces that act on particles during filtration as well as those filter characteristics that influence filter pressure drop. However, a thorough investigation of these forces and characteristics using measurements of currently available FFRs has not been undertaken. Filter characteristics such as fiber diameter and filter depth were measured from samples taken from six currently-available N95 FFRs from three manufacturers. A filtration model was developed that included diffusion, inertial and electrostatic forces to estimate the filtration of an aerosol with a Boltzmann charge distribution. The diameter of the filter fibers was modeled as either a single "effective" diameter or as a lognormal distribution of diameters. Both modeling schemes produced an efficiency curve that simulated efficiency measurements made over a range of particle diameters (0.01 - 0.3 µm) with the use of a scanning mobility particle sizer in the region where efficiency is at a minimum. However, the method using a distribution of fiber diameters produced a better fit for particles > 0.1 µm. The coefficients associated with a simple form of the diffusion equation constituting a power law incorporating the Peclet number were adjusted to enhance model accuracy. Likewise, the fiber charge of the electret fibers was also adjusted to maximize model fit but remained within levels reported by others. A filter pressure drop model was also developed. Results demonstrated the need for a pressure drop model applicable to N95s relative to existing models developed with the use of fibers with larger diameters than those used in current N95 FFRs. A set of N95 FFR characteristics are provided that can be used to develop models of typical N95 FFR filter performance and pressure drop in future studies.


Subject(s)
Air Pollutants, Occupational , Respiratory Protective Devices , United States , N95 Respirators , Air Pollutants, Occupational/analysis , National Institute for Occupational Safety and Health, U.S. , Particle Size , Equipment Design , Inhalation Exposure/prevention & control , Inhalation Exposure/analysis , Filtration , Aerosols/analysis
3.
J Appl Polym Sci ; 140(5): e53406, 2023 Feb 05.
Article in English | MEDLINE | ID: mdl-37034442

ABSTRACT

During the global spread of COVID-19, high demand and limited availability of melt-blown filtration material led to a manufacturing backlog of N95 Filtering Facepiece Respirators (FFRs). This shortfall prompted the search for alternative filter materials that could be quickly mass produced while meeting N95 FFR filtration and breathability performance standards. Here, an unsupported, nonwoven layer of uncharged polystyrene (PS) microfibers was produced via electrospinning that achieves N95 performance standards based on physical parameters (e.g., filter thickness) alone. PS microfibers 3-6 µm in diameter and deposited in an ~5 mm thick filter layer are favorable for use in FFRs, achieving high filtration efficiencies (≥97.5%) and low pressure drops (≤15 mm H2O). The PS microfiber filter demonstrates durability upon disinfection with hydroxyl radicals (•OH), maintaining high filtration efficiencies and low pressure drops over six rounds of disinfection. Additionally, the PS microfibers exhibit antibacterial activity (1-log removal of E. coli) and can be modified readily through integration of silver nanoparticles (AgNPs) during electrospinning to enhance their activity (≥3-log removal at 25 wt% AgNP integration). Because of their tunable performance, potential reusability with disinfection, and antimicrobial properties, these electrospun PS microfibers may represent a suitable, alternative filter material for use in N95 FFRs.

4.
Environ Sci Atmos ; 3(1): 238-246, 2023 Jan 19.
Article in English | MEDLINE | ID: mdl-36743127

ABSTRACT

Various metals have toxic effects by the inhalation route, and electric arc furnace (EAF) steel slag is known to contain metals with a potential for toxicity to humans. In some states, EAF slag is applied to unpaved (gravel) roads as a low-cost supplement to limestone and other crushed stone, where it may be a public health concern for the local population. This study compared the mass of selected metals in the PM10 size fraction of fugitive dust from roads where slag was applied to metals in fugitive dust where slag was not applied. Manganese, designated by the EPA as a hazardous air pollutant (HAP) and one of the primary metals of concern in the slag, was 1.3 times more concentrated in the PM10 fraction from the slag-covered roads as compared to the PM10 fraction from the non-slag-covered roads, but that increase was not significant (p = 0.26). Other metals detected in the airborne dust from both slag-covered and non-slag-covered roads that are also designated as HAPs are antimony, arsenic, chromium, cobalt, lead, nickel, and selenium. In addition, hourly sampling of PM10 and metals in the PM10 fraction was conducted at one of the sample locations where slag had been applied to the road. Manganese mass in the PM10 was positively correlated (Spearman r = 0.86) with the particulate mass in the PM10. Wind direction and the interaction of traffic and wind direction were found to be statistically significant factors affecting manganese concentrations in the fugitive emissions from the road to which EAF slag had been applied. This research demonstrated that application of steel slag can result in elevated levels of manganese in the airborne dust generated by vehicular traffic on the unpaved roadway.

5.
J Occup Environ Hyg ; 19(12): 696-705, 2022 12.
Article in English | MEDLINE | ID: mdl-36197119

ABSTRACT

With advances in technology, there are an increasing number of direct-reading instruments available to occupational health and safety professionals to evaluate occupational aerosol exposures. Despite the wide array of direct-reading instruments available to professionals, the adoption of direct-reading technology to monitor workplace exposures has been limited, partly due to a lack of knowledge on how the instruments operate, how to select an appropriate instrument, and challenges in data analysis techniques. This paper presents a review of direct-reading aerosol instruments available to occupational health and safety professionals, describes the principles of operation, guides instrument selection based on the workplace and exposure, and discusses data analysis techniques to overcome these barriers to adoption. This paper does not cover all direct-reading instruments for aerosols but only those that an occupational health and safety professional could use in a workplace to evaluate exposures. Therefore, this paper focuses on instruments that have the most potential for workplace use due to their robustness, past workplace use, and price with regard to return on investment. The instruments covered in this paper include those that measure aerosol number concentration, mass concentration, and aerosol size distributions.


Subject(s)
Air Pollutants, Occupational , Occupational Exposure , Occupational Health , Humans , Air Pollutants, Occupational/analysis , Particle Size , Environmental Monitoring/methods , Reading , Occupational Exposure/prevention & control , Occupational Exposure/analysis , Aerosols/analysis
6.
J Occup Environ Hyg ; 19(12): 706-729, 2022 12.
Article in English | MEDLINE | ID: mdl-36197433

ABSTRACT

Direct reading instruments (DRIs) for aerosols have been used in industrial hygiene practice for many years, but their potential has not been fully realized by many occupational health and safety professionals. Although some DRIs quantify other metrics, this article will primarily focus on DRIs that measure aerosol number, size, or mass. This review addresses three applications of aerosol DRIs that occupational health and safety professionals can use to discern, characterize, and document exposure conditions and resolve aerosol-related problems in the workplace. The most common application of aerosol DRIs is the evaluation of engineering controls. Examples are provided for many types of workplaces and situations including construction, agriculture, mining, conventional manufacturing, advanced manufacturing (nanoparticle technology and additive manufacturing), and non-industrial sites. Aerosol DRIs can help identify the effectiveness of existing controls and, as needed, develop new strategies to reduce potential aerosol exposures. Aerosol concentration mapping (ACM) using DRI data can focus attention on emission sources in the workplace spatially illustrate the effectiveness of controls and constructively convey concerns to management and workers. Examples and good practices of ACM are included. Video Exposure Monitoring (VEM) is another useful technique in which video photography is synced with the concentration output of an aerosol DRI. This combination allows the occupational health and safety professional to see what tasks, environmental situations, and/or worker actions contribute to aerosol concentration and potential exposure. VEM can help identify factors responsible for temporal variations in concentration. VEM can assist with training, engage workers, convince managers about necessary remedial actions, and provide for continuous improvement of the workplace environment. Although using DRIs for control evaluation, ACM and VEM can be time-consuming, the resulting information can provide useful data to prompt needed action by employers and employees. Other barriers to adoption include privacy and security issues in some worksites. This review seeks to provide information so occupational health and safety professionals can better understand and effectively use these powerful applications of aerosol DRIs.


Subject(s)
Air Pollutants, Occupational , Nanoparticles , Occupational Exposure , Occupational Health , Humans , Occupational Exposure/prevention & control , Occupational Exposure/analysis , Workplace , Aerosols/analysis , Environmental Monitoring/methods , Air Pollutants, Occupational/analysis
7.
J Occup Environ Hyg ; 19(10-11): 615-628, 2022.
Article in English | MEDLINE | ID: mdl-35969803

ABSTRACT

The use of filtering facepiece respirators (FFRs) of various types increased dramatically by both workers and the public during the ongoing COVID-19 pandemic. This increased use has, likewise, instigated a proliferation of research on the qualities of FFRs. An aspect of FFR development and optimization involves the use of mathematical models that predict filter efficiency based on various filter characteristics while also considering a number of particle capture forces. An evaluation of current literature failed to identify a publication that provides a comprehensive assessment of the models developed to predict filter efficiency. The purpose of this review was, therefore, to describe models developed to include the forces associated with diffusion, interception, impaction, and electrostatic attraction as they contribute to the efficiency of an entire filter. The literature review was augmented with figures created with the use of many of the models discussed to compare different models of the same force as well as to illustrate the influence of electrostatic forces on overall filter efficiency.


Subject(s)
Air Pollutants, Occupational , COVID-19 , Respiratory Protective Devices , United States , Humans , Air Pollutants, Occupational/analysis , National Institute for Occupational Safety and Health, U.S. , Particle Size , Pandemics/prevention & control , Filtration , Materials Testing/methods , COVID-19/prevention & control , Respiratory Aerosols and Droplets , Ventilators, Mechanical
8.
Antibiotics (Basel) ; 11(7)2022 Jul 19.
Article in English | MEDLINE | ID: mdl-35884228

ABSTRACT

Antimicrobial resistance (AMR) is continuing to grow across the world. Though often thought of as a mostly public health issue, AMR is also a major agricultural and environmental problem. As such, many researchers refer to it as the preeminent One Health issue. Aerial transport of antimicrobial-resistant bacteria via bioaerosols is still poorly understood. Recent work has highlighted the presence of antibiotic resistance genes in bioaerosols. Emissions of AMR bacteria and genes have been detected from various sources, including wastewater treatment plants, hospitals, and agricultural practices; however, their impacts on the broader environment are poorly understood. Contextualizing the roles of bioaerosols in the dissemination of AMR necessitates a multidisciplinary approach. Environmental factors, industrial and medical practices, as well as ecological principles influence the aerial dissemination of resistant bacteria. This article introduces an ongoing project assessing the presence and fate of AMR in bioaerosols across Canada. Its various sub-studies include the assessment of the emissions of antibiotic resistance genes from many agricultural practices, their long-distance transport, new integrative methods of assessment, and the creation of dissemination models over short and long distances. Results from sub-studies are beginning to be published. Consequently, this paper explains the background behind the development of the various sub-studies and highlight their shared aspects.

9.
Part Fibre Toxicol ; 19(1): 40, 2022 06 13.
Article in English | MEDLINE | ID: mdl-35698146

ABSTRACT

BACKGROUND: It has been shown that copper oxide nanoparticles (CuO NPs) induce pulmonary toxicity after acute or sub-acute inhalation exposures. However, little is known about the biodistribution and elimination kinetics of inhaled CuO NPs from the respiratory tract. The purposes of this study were to observe the kinetics of pulmonary inflammation during and after CuO NP sub-acute inhalation exposure and to investigate copper (Cu) biodistribution and clearance rate from the exposure site and homeostasis of selected trace elements in secondary organs of BALB/c mice. RESULTS: Sub-acute inhalation exposure to CuO NPs led to pulmonary inflammation represented by increases in lactate dehydrogenase, total cell counts, neutrophils, macrophages, inflammatory cytokines, iron levels in bronchoalveolar lavage (BAL) fluid, and lung weight changes. Dosimetry analysis in lung tissues and BAL fluid showed Cu concentration increased steadily during exposure and gradually declined after exposure. Cu elimination from the lung showed first-order kinetics with a half-life of 6.5 days. Total Cu levels were significantly increased in whole blood and heart indicating that inhaled Cu could be translocated into the bloodstream and heart tissue, and potentially have adverse effects on the kidneys and spleen as there were significant changes in the weights of these organs; increase in the kidneys and decrease in the spleen. Furthermore, concentrations of selenium in kidneys and iron in spleen were decreased, pointing to disruption of trace element homeostasis. CONCLUSIONS: Sub-acute inhalation exposure of CuO NPs induced pulmonary inflammation, which was correlated to Cu concentrations in the lungs and started to resolve once exposure ended. Dosimetry analysis showed that Cu in the lungs was translocated into the bloodstream and heart tissue. Secondary organs affected by CuO NPs exposure were kidneys and spleen as they showed the disruption of trace element homeostasis and organ weight changes.


Subject(s)
Metal Nanoparticles , Nanoparticles , Pneumonia , Trace Elements , Animals , Copper/toxicity , Disease Models, Animal , Inhalation Exposure/adverse effects , Iron , Metal Nanoparticles/toxicity , Mice , Mice, Inbred BALB C , Nanoparticles/toxicity , Oxides , Tissue Distribution
10.
J Occup Environ Hyg ; 18(12): 579-589, 2021 12.
Article in English | MEDLINE | ID: mdl-34612175

ABSTRACT

The inhalable aerosol sampling criterion has been developed to characterize the efficiency of particles entering the nose and/or mouth. However, pesticides can exist in the air in both vapor and particulate phases, which complicates exposure assessments. The American Conference of Governmental Industrial Hygienists (ACGIH) has established an IFV (inhalable fraction and vapor) endnote for chemicals such as many pesticides that need to be evaluated for both their inhalable fraction and vapor concentrations to fully characterize worker exposures. The purpose of this study was to evaluate the particle-phase collection efficiency of a commonly-used pesticide sampler, the OSHA Versatile Sampler (OVS) as well as a recently developed sampler, the IFV Pro. The OVS was not designed as an inhalable aerosol sampler, whereas the IFV Pro contains a sampling head scaled to that of the Institute of Medicine (IOM) sampler, which is known to closely follow the inhalable sampling criterion. Laboratory experiments involving a vertical-flow, low-velocity scheme, and finely graded test dusts with known median aerodynamic diameter were used to determine sampler collection efficiencies. The collection efficiency of the OVS was evaluated as recommended by the manufacturer and after two modifications made to potentially improve its collection efficiency. The OVS was found to substantially under-sample relative to the inhalable criterion, and the two modifications did not provide substantial improvements to the original configuration. Conversely, the collection efficiency of the IFV Pro was found to compare closely to that of the IOM, although collecting 9% more mass. When applied side-by-side with the OVS sampler in a chamber into which ethylene glycol was sprayed as a proxy for a pesticide, the IFV Pro collected an average of 1.9-fold more mass than the OVS for the same flow rate and sample time.


Subject(s)
Air Pollutants, Occupational , Occupational Exposure , Pesticides , Aerosols/analysis , Air Pollutants, Occupational/analysis , Environmental Monitoring , Inhalation Exposure/analysis , Occupational Exposure/analysis , Particle Size , United States , United States Occupational Safety and Health Administration
11.
J Occup Environ Hyg ; 18(6): 265-275, 2021 06.
Article in English | MEDLINE | ID: mdl-33989113

ABSTRACT

The COVID-19 pandemic has caused a high demand for respiratory protection among health care workers in hospitals, especially surgical N95 filtering facepiece respirators (FFRs). To aid in alleviating that demand, a survey of commercially available filter media was conducted to determine whether any could serve as a substitute for an N95 FFR while held in a 3D-printed mask (Stopgap Surgical Face Mask from the NIH 3D Print Exchange). Fourteen filter media types and eight combinations were evaluated for filtration efficiency, breathing resistance (pressure drop), and liquid penetration. Additional testing was conducted to evaluate two filter media disinfection methods in the event that the filters were reused in a hospital setting. Efficiency testing was conducted in accordance with the procedures established for approving an N95 FFR. One apparatus used a filter-holding device and another apparatus employed a manikin head to which the 3D-printed mask could be sealed. The filter media and combinations exhibited collection efficiencies varied between 3.9% and 98.8% when tested with a face velocity comparable to that of a standard N95 FFR at the 85 L min-1 used in the approval procedure. Breathing resistance varied between 10.8 to >637 Pa (1.1 to > 65 mm H2O). When applied to the 3D-printed mask efficiency decreased by an average of 13% and breathing resistance increased 4-fold as a result of the smaller surface area of the filter media when held in that mask compared to that of an N95 FFR. Disinfection by dry heat, even after 25 cycles, did not significantly affect filter efficiency and reduced viral infectivity by > 99.9%. However, 10 cycles of 59% vaporized H2O2 significantly (p < 0.001) reduced filter efficiency of the media tested. Several commercially available filter media were found to be potential replacements for the media used to construct the typical cup-like N95 FFR. However, their use in the 3D-printed mask demonstrated reduced efficiency and increased breathing resistance at 85 L min-1.


Subject(s)
COVID-19/prevention & control , Disinfection/standards , Equipment Contamination/prevention & control , Materials Testing/standards , N95 Respirators/virology , Occupational Exposure/prevention & control , Pandemics/prevention & control , Air Pollutants, Occupational/analysis , Equipment Failure Analysis/statistics & numerical data , Guidelines as Topic , Humans , Inhalation Exposure/analysis , SARS-CoV-2
12.
J Prev Med Public Health ; 54(1): 31-36, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33618497

ABSTRACT

OBJECTIVES: Non-traditional materials are used for mask construction to address personal protective equipment shortages during the coronavirus disease 2019 (COVID-19) pandemic. Reusable masks made from surgical sterilization wrap represent such an innovative approach with social media frequently referring to them as "N95 alternatives." This material was tested for particle filtration efficiency and breathability to clarify what role they might have in infection prevention and control. METHODS: A heavyweight, double layer sterilization wrap was tested when new and after 2, 4, 6, and 10 autoclave sterilizing cycles and compared with an approved N95 respirator and a surgical mask via testing procedures using a sodium chloride aerosol for N95 efficiency testing similar to 42 CFR 84.181. Pressure testing to indicate breathability was also conducted. RESULTS: The particle filtration efficiency for the sterilization wrap ranged between 58% to 66%, with similar performance when new and after sterilizing cycles. The N95 respirator and surgical mask performed at 95% and 68% respectively. Pressure drops for the sterilization wrap, N95 and surgical mask were 10.4 mmH2O, 5.9 mmH2O, and 5.1 mmH2O, respectively, well below the National Institute for Occupational Safety and Health limits of 35 mmH2O during initial inhalation and 25 mmH2O during initial exhalation. CONCLUSIONS: The sterilization wrap's particle filtration efficiency is much lower than a N95 respirator, but falls within the range of a surgical mask, with acceptable breathability. Performance testing of non-traditional mask materials is crucial to determine potential protection efficacy and for correcting misinterpretation propagated through popular media.


Subject(s)
Filtration/standards , Masks/standards , Filtration/instrumentation , Filtration/statistics & numerical data , Humans , Masks/microbiology , Masks/virology , Occupational Exposure/prevention & control , Pandemics/prevention & control , Personal Protective Equipment/standards , Personal Protective Equipment/statistics & numerical data , Sterilization/methods , Sterilization/standards , Sterilization/statistics & numerical data
13.
J Am Coll Emerg Physicians Open ; 2(1): e12335, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33521786

ABSTRACT

STUDY OBJECTIVE: The COVID-19 pandemic has resulted in widespread shortages of personal protective equipment, including N95 respirators. Although basic surgical facemasks are more commonly available, their efficacy is limited due primarily to their poor face seal. This pilot study examined the impact of a rubber band mask brace on a basic surgical mask, as determined by quantitative fit testing. METHODS: Subjects wearing a basic surgical facemask and the rubber band mask brace underwent quantitative fit testing using machinery designed to certify N95 mask fit. Subjects were tested with the brace anchored behind their ears, with a paperclip behind the head, and on the side knobs of their face shields. The primary outcome measure was whether the subject passed the quantitative fit test at or above the Occupational Safety and Health Administration (OSHA)-verified standard for N95 masks. RESULTS: Subjects (n = 11) were 54.5% female, with a median height of 70 inches (interquartile range [IQR] = 68-74), weight of 170 pounds (IQR = 145-215), and body mass index (BMI) of 24.6 (IQR = 22.2-27.2), and encompassing 5 distinct N95 mask fit types. We found that 45%, 100%, and 100% of subjects passed the quantitative fit test when the brace was anchored behind the ears, with a paperclip and on a face shield, respectively. CONCLUSION: Of the 11 subjects included in the analysis, across a range of body habitus and N95 mask fit types, all passed the quantitative fit test when the mask brace was anchored on either face shield or with a paperclip. This data suggests that although the brace does not create an N95 equivalent in terms of filtration, it would offer improved protection from airborne viruses when worn with a basic surgical mask.

14.
Infect Control Hosp Epidemiol ; 42(3): 253-260, 2021 03.
Article in English | MEDLINE | ID: mdl-32783787

ABSTRACT

BACKGROUND: Personal protective equipment (PPE) is a critical need during the coronavirus disease 2019 (COVID-19) pandemic. Alternative sources of surgical masks, including 3-dimensionally (3D) printed approaches that may be reused, are urgently needed to prevent PPE shortages. Few data exist identifying decontamination strategies to inactivate viral pathogens and retain 3D-printing material integrity. OBJECTIVE: To test viral disinfection methods on 3D-printing materials. METHODS: The viricidal activity of common disinfectants (10% bleach, quaternary ammonium sanitizer, 3% hydrogen peroxide, or 70% isopropanol and exposure to heat (50°C, and 70°C) were tested on four 3D-printed materials used in the healthcare setting, including a surgical mask design developed by the Veterans' Health Administration. Inactivation was assessed for several clinically relevant RNA and DNA pathogenic viruses, including severe acute respiratory coronavirus virus 2 (SARS-CoV-2) and human immunodeficiency virus 1 (HIV-1). RESULTS: SARS-CoV-2 and all viruses tested were completely inactivated by a single application of bleach, ammonium quaternary compounds, or hydrogen peroxide. Similarly, exposure to dry heat (70°C) for 30 minutes completely inactivated all viruses tested. In contrast, 70% isopropanol reduced viral titers significantly less well following a single application. Inactivation did not interfere with material integrity of the 3D-printed materials. CONCLUSIONS: Several standard decontamination approaches effectively disinfected 3D-printed materials. These approaches were effective in the inactivation SARS-CoV-2, its surrogates, and other clinically relevant viral pathogens. The decontamination of 3D-printed surgical mask materials may be useful during crisis situations in which surgical mask supplies are limited.


Subject(s)
COVID-19/prevention & control , Disinfectants/pharmacology , Disinfection/methods , Masks , SARS-CoV-2/drug effects , Virus Inactivation , 2-Propanol , DNA, Viral/drug effects , Decontamination/methods , HIV-1/drug effects , Healthy Volunteers , Hot Temperature , Humans , Hydrogen Peroxide , Personal Protective Equipment , Printing, Three-Dimensional , RNA, Viral/drug effects , Virus Diseases/prevention & control
15.
Aerosol Sci Technol ; 54(10): 1169-1182, 2020.
Article in English | MEDLINE | ID: mdl-33100458

ABSTRACT

Hygroscopic growth models are currently of interest as aids for targeting the deposition of inhaled drug particles in preferred areas of the lung that will maximize their pharmaceutical effect. Mathematical models derived to estimate hygroscopic growth over time have been previously developed but have not been thoroughly validated. For this study, model validation involved a comparison of modeled values to measured values when the growing droplet had reached equilibrium. A second validation process utilized a novel system to measure the growth of a droplet on a microscope coverslip relative to modeled values when the droplet is undergoing the initial rapid growth phase. Various methods currently used to estimate the water activity of the growing droplet, which influences the droplet growth rate, were also compared. Results indicated that a form of the hygroscopic growth model that utilizes coupled-differential equations to estimate droplet diameter and temperature over time was valid throughout droplet growth until it reached its equilibrium size. Accuracy was enhanced with the use of a polynomial expression to estimate water activity relative to the use of a simplified estimate of water activity based on Raoult's Law. Model accuracy was also improved when constraining the film of salt solution surrounding the dissolving salt core at saturation.

16.
NanoImpact ; 172020 Jan.
Article in English | MEDLINE | ID: mdl-32968699

ABSTRACT

Cellulose nanofibers (CNFs) are an emerging engineered nanomaterial that are utilized in a variety of applications, including as a replacement for urea-formaldehyde, and other adhesives, as the binding agent in manufactured fiber and particle boards. To ensure the health and well-being of those producing, installing, or otherwise using cellulose nanofiber boards (CNFBs) it is imperative that the particulate matter (PM) produced during CNFB manipulation be evaluated for toxicity. We developed and internally verified a generation system to examine the PM produced by sanding CNFB using aluminum oxide sandpaper. With 80-grit sandpaper our system produced a low dispersity aerosol, as determined by a scanning mobility particle sizer and an optical particle counter, with a geometric mean of 28 nm (GSD = 1.60). ICP-MS evaluation showed little difference in metal concentrations between CNFB PM and nonsanded CNFB stock. We then used the system to simultaneously generate and expose both male and female C57BL/6J mice acutely for 4 hours at a concentration of 7.9 mg/m3. Sham-exposed controls were treated similarly but without sanding the CNFB. Analysis of bronchoalveolar lavage (BAL) fluid biomarkers showed no signs of inflammatory response at either 4- or 24-hours post exposure. Further, BAL cell viability, number of total cells, and pulmonary cellular recruitment were not significantly changed between the sham-exposed controls and CNFB-exposed mice. Histology further confirmed no pulmonary toxicity as a result of CNFB PM inhalation. We conclude that inhalation of a high concentration of the PM from manipulation of a CNFB did not produce acute toxic responses within 24 hours of exposure.

17.
NanoImpact ; 182020 Apr.
Article in English | MEDLINE | ID: mdl-32968700

ABSTRACT

Characterizations and in vitro toxicity screening were performed on metal oxide engineered nanomaterials (ENMs) independently comprising ZnO, CuO, CeO2, Fe2O3, WO3, V2O5, TiO2, Al2O3 and MgO. Nanomaterials that exhibited the highest toxicity responses in the in vitro screening assays (ZnO, CuO, and V2O5) and the lesser explored material WO3 were tested for acute pulmonary toxicity in vivo. Female and male mice (C57Bl/6J) were exposed to aerosolized metal oxide ENMs in a nose-only exposure system and toxicity outcomes (biomarkers of cytotoxicity, immunotoxicity, inflammation, and lung histopathology) at 4 and 24 h after the start of exposure were assessed. The studies were performed as part of the NIEHS Nanomaterials Health Implications Research consortium with the purpose of investigating the effects of ENMs on various biological systems. ENMs were supplied by the Engineered Nanomaterials Resource and Coordination Core. Among the ENMs studied, the highest toxicity was observed for CuO and ZnO NPs in both in vitro and in vivo acute models. Compared to sham-exposed controls, there was a significant increase in bronchoalveolar lavage neutrophils and proinflammatory cytokines and a loss of macrophage viability at both 4 h and 24 h for ZnO and CuO but not seen for V2O5 or WO3. These effects were observed in both female and male mice. The cell viability performed after in vitro exposure to ENMs and assessment of lung inflammation after acute inhalation exposure in vivo were shown to be sensitive endpoints to predict ENM acute toxicity.

18.
Iowa Orthop J ; 40(1): 191-193, 2020.
Article in English | MEDLINE | ID: mdl-32754006

ABSTRACT

Background: Exposure to methyl methacrylate vapor (MMA) presents an occupational risk to orthopedic surgeons and ancillary personnel in the operating room. The purpose of this study was to identify a disposable face mask to reduce MMA organic vapor inhalation in the operative suite. Methods: First, the effectiveness of MMA vapor filtration was determined in the laboratory. A section of activated carbon impregnated filter face mask (Model 8514, 3M Inc.) was exposed to 150 ppm MMA vapor and MMA ppm of filtered air was monitored until MMA vapor was detectable. The face mask was then worn as directed in the operating room during routine cement mixing during total knee arthroplasty to determine the exposure to MMA vapors during the procedure both with and without the activated carbon impregnated filter face mask. Results: The activated carbon impregnated face mask was effective in reducing MMA vapor inhalation to non-detectable levels for up to 40 minutes in the laboratory at steady-state exposure of 150 ppm MMA vapor as well as throughout cement mixing and curing in the operative suite during routine total knee arthroplasty. Conclusions: An activated carbon impregnated face mask offers a solution for the orthopedic surgeon and supporting personnel who wish to limit their exposure to MMA vapors due to health concerns.Level of Evidence: III.


Subject(s)
Air Pollutants, Occupational/analysis , Bone Cements/analysis , Inhalation Exposure/prevention & control , Masks , Methylmethacrylate/analysis , Occupational Exposure/analysis , Occupational Exposure/prevention & control , Arthroplasty, Replacement, Knee , Humans , Operating Rooms , Quality Improvement
19.
J Occup Environ Hyg ; 17(6): 262-273, 2020 06.
Article in English | MEDLINE | ID: mdl-32286917

ABSTRACT

Aethalometers are direct-reading instruments primarily used for measuring black carbon (BC) concentrations in workplace and ambient atmospheres. Aethalometer BC measurements of carbon nanotubes (CNTs) were compared to measurements made by other methods when subjected to high (>30 µg/m3) and low (1-30 µg/m3) CNT aerosol concentrations representing worst-case and typical workplace concentrations, respectively. A laboratory-based system was developed to generate carbon black, as an example of a nearly pure carbon, micron-sized aerosol, and two forms of multi-walled carbon nanotubes (CNTs): small-diameter (<8 nm) and large-diameter (50-80 nm). High-concentration trials were conducted during which a scanning mobility particle sizer (SMPS) was used to track particle count concentrations over time. Relative to the behavior of the SMPS counts over time, aethalometer readings exhibited a downward drift, which is indicative of aethalometer response subjected to high BC loading on the receiving filter of the instrument. A post-sample mathematical method was applied that adequately corrected for the drift. Low-concentration trials, during which concentration drift did not occur, were conducted to test aethalometer accuracy. The average BC concentration during a trial was compared to elemental carbon (EC) concentration sampled with a quartz-fiber filter and quantified by NIOSH Method 5040. The CB and large-diameter CNT concentrations measured with the aethalometer produced slopes when regressed on EC that were not significantly different from unity, whereas the small-diameter CNTs were under-sampled by the aethalometer relative to EC. These results indicate that aethalometer response may drift when evaluating CNT exposure scenarios, such as cleaning and powder handling, that produce concentrations >30 µg/m3. However, aethalometer accuracy remains consistent over time when sampling general work zones in which CNT concentrations are expected to be <30 µg/m3. A calibration check of aethalometer response relative to EC measured with Method 5040 is recommended to ensure that the aethalometer readings are not under sampling CNT concentrations as occurred with one of the CNTs evaluated in this study.


Subject(s)
Air Pollutants, Occupational/analysis , Environmental Monitoring/instrumentation , Nanotubes, Carbon/analysis , Particulate Matter/analysis , Soot/analysis
20.
J Aerosol Sci ; 146: 105581, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32346183

ABSTRACT

This study numerically investigates the effect of hygroscopicity on transport and deposition of particles in severe asthmatic lungs with distinct airway structures. The study human subjects were selected from two imaging-based severe asthmatic clusters with one characterized by non-constricted airways and the other by constricted airways in the lower left lobe (LLL). We compared the deposition fractions of sodium chloride (NaCl) particles with a range of aerodynamic diameters (1-8 µm) in cluster archetypes under conditions with and without hygroscopic growth. The temperature and water vapor distributions in the airways were simulated with an airway wall boundary condition that accounts for variable temperature and water vapor evaporation at the interface between the lumen and the airway surface liquid layer. On average, the deposition fraction increased by about 6% due to hygroscopic particle growth in the cluster subjects with constricted airways, while it increased by only about 0.5% in those with non-constricted airways. The effect of particle growth was most significant for particles with an initial diameter of 2 µm in the cluster subjects with constricted airways. The effect diminished with increasing particle size, especially for particles with an initial diameter larger than 4 µm. This suggests the necessity to differentiate asthmatic subjects by cluster in engineering the aerosol size for tailored treatment. Specifically, the treatment of severe asthmatic subjects who have constricted airways with inhalation aerosols may need submicron-sized hygroscopic particles to compensate for particle growth, if one targets for delivering to the peripheral region. These results could potentially inform the choice of particle size for inhalational drug delivery in a cluster-specific manner.

SELECTION OF CITATIONS
SEARCH DETAIL
...