Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 39
Filter
1.
Clin Radiol ; 68(3): e123-7, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23245275

ABSTRACT

AIM: To assess the feasibility of an unenhanced, flow-sensitive, alternating inversion recovery-balanced steady-state free precession (FAIR TrueFISP) arterial spin labelling (ASL) magnetic resonance imaging (MRI) technique for quantification of breast cancer perfusion. MATERIALS AND METHODS: Eighteen untreated breast tumour patients (mean age 53 ± 17 years, range 30-68 years) and four healthy controls (mean age 51 ± 14 years, range 33-68 years) were enrolled in this study and were imaged using a clinical 1.5 T MRI machine. Perfusion measurements were performed using a coronal single-section ASL FAIR TrueFISP technique in addition to a routine breast MRI examination. T1 relaxation time of normal breast parenchyma was determined in four healthy volunteers using the variable flip angle approach. The definitive diagnosis was obtained at histology after biopsy or surgery and was available for all patients. RESULTS: ASL perfusion was successfully acquired in 13 of 18 tumour patients and in all healthy controls. The mean ASL perfusion of invasive ductal carcinoma tissue was significantly higher (88.2 ± 39.5 ml/100 g/min) compared to ASL perfusion of normal breast parenchyma (24.9 ± 12.7 ml/100 g/min; p < 0.05) and invasive lobular carcinoma (30.5 ± 4.3 ml/100 g/min; p < 0.05). No significant difference was found between the mean ASL perfusion of normal breast parenchyma and invasive lobular carcinoma tissue (p = 0.97). CONCLUSION: ASL MRI enables quantification of breast cancer perfusion without the use of contrast material. However, its impact on diagnosis and therapy management of breast tumours has to be evaluated in larger patient studies.


Subject(s)
Breast Neoplasms/pathology , Magnetic Resonance Angiography/methods , Neovascularization, Pathologic/pathology , Spin Labels , Adult , Aged , Analysis of Variance , Biopsy , Blood Flow Velocity , Breast Neoplasms/surgery , Case-Control Studies , Feasibility Studies , Female , Humans , Image Interpretation, Computer-Assisted , Imaging, Three-Dimensional , Middle Aged , Neovascularization, Pathologic/surgery
2.
Urologe A ; 46(12): 1710-4, 2007 Dec.
Article in German | MEDLINE | ID: mdl-17932642

ABSTRACT

PURPOSE: We investigated the feasibility of using flat panel volumetric computer tomography (fpVCT) for the detection of orthotopically implanted renal carcinomas in nude mice. MATERIALS AND METHODS: One million renal cell carcinoma cells [A-498 line (Braunschweig, Germany), in 0.2 ml phosphate-buffered solution (PBS), pH 7.4] were injected into the left kidney of each of the eight nude mice. Each mouse was imaged twice (12 and 16 weeks after implantation) with fpVCT (GE prototype with circular gantry with two 1024 x 1024, 200 microm pixel size, aSi/CsI flat panel detector) after injection of 200 microl contrast medium to check for tumour spread. After 16 weeks the mice were killed and dissected, and the imaging findings in liver, kidneys and lung were compared with the macroscopic findings. RESULTS: No local evidence of tumour or of metastatic spread was seen on fpVCT after 12 weeks in any of the mice. After 16 weeks fpVCT revealed tumour growth in 6 of the 16 kidneys. Two mice had each developed a multifocal renal cell carcinoma and one mouse, a bilateral renal tumour manifestation. In one mouse liver metastases were seen. The fpVCT findings correlated well with the observations recorded in the pathological examination. CONCLUSION: fpVCT is an innovative and noninvasive imaging procedure that can be used for longitudinal investigation of tumour progression following orthotopic implantation of renal cell carcinoma to small animals. The use of a system of this kind will make a decisive contribution to reducing the number of animals used in experimental test projects.


Subject(s)
Carcinoma, Renal Cell/diagnostic imaging , Cone-Beam Computed Tomography , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Kidney Neoplasms/diagnostic imaging , Animals , Carcinoma, Renal Cell/pathology , Carcinoma, Renal Cell/secondary , Disease Progression , Feasibility Studies , Kidney/diagnostic imaging , Kidney/pathology , Kidney Neoplasms/pathology , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/pathology , Liver Neoplasms/secondary , Male , Mice , Mice, Nude , Neoplasm Transplantation/pathology , Neoplasms, Multiple Primary/diagnostic imaging , Neoplasms, Multiple Primary/pathology
3.
Rofo ; 179(10): 1025-34, 2007 Oct.
Article in German | MEDLINE | ID: mdl-17786893

ABSTRACT

After cystectomy two principal types of urinary diversion are used for the surgical reconstruction of the urinary tract: incontinent and continent. In the continent type of urinary diversion, a differentiation must be made between those with and without catheterization for voiding. Besides urothelial cancer other reasons for urinary diversion include neurogenic bladder palsy (connatal or acquired) due to meningomyelocele or connatal diseases like bladder exstrophy. The main objective of the clinical urologist when selecting urinary diversion are to achieve continence and to preserve upper urinary tract function. Knowledge of the different forms of urinary diversion is critical for the exact interpretation of the images. This review presents the typical imaging techniques after a description of the basic surgical features of urinary diversion. CT urography and MR urography are becoming increasingly important as further imaging tools for controlling urinary diversions.


Subject(s)
Bladder Exstrophy/surgery , Carcinoma, Transitional Cell/surgery , Magnetic Resonance Imaging , Tomography, X-Ray Computed , Urinary Bladder Neoplasms/surgery , Urinary Bladder, Neurogenic/surgery , Urinary Diversion/methods , Urinary Reservoirs, Continent , Urography , Cystectomy/adverse effects , Cystectomy/mortality , Humans , Imaging, Three-Dimensional , Meningomyelocele/complications , Tomography, Spiral Computed , Ureterostomy , Urinary Bladder, Neurogenic/etiology , Urinary Diversion/adverse effects , Urinary Tract Physiological Phenomena
4.
Rofo ; 178(9): 862-71, 2006 Sep.
Article in German | MEDLINE | ID: mdl-16953478

ABSTRACT

PURPOSE: To assess a new flat panel volume computed tomography (FP-VCT) with very high isotropic spatial resolution as well as high Z-axis coverage. MATERIALS AND METHODS: The prototype of an FP-VCT scanner with a detector cell size of 0.2 mm was used for numerous phantom studies, specimen examinations, and animal research projects. RESULTS: The high spatial resolution of the new system can be used to accurately determine solid tumor volume, thus allowing for earlier assessment of the therapeutic response. In animal experimentation, whole-body perfusion mapping of mice is feasible. The high spatial resolution also improves the classification of coronary artery atherosclerotic plaques in the isolated post mortem human heart. With the depiction of intramyocardial segments of the coronary arteries, investigations of myocardial collateral circulation are feasible. In skeletal applications, an accurate analysis of the smallest bony structures, e. g., petrous bone and dental preparations, can be successfully performed, as well as investigations of repetitive studies of fracture healing and the treatment of osteoporosis. CONCLUSION: The introduction of FP-VCT opens up new applications for CT, including the field of molecular imaging, which are highly attractive for future clinical applications. Present limitations include limited temporal resolution and necessitate further improvement of the system.


Subject(s)
Tomography, X-Ray Computed , Animals , Bone and Bones/diagnostic imaging , Heart/diagnostic imaging , Mice , Microradiography/instrumentation , Rats , Sarcoma, Experimental/diagnostic imaging , Tomography, X-Ray Computed/instrumentation , Tomography, X-Ray Computed/methods
5.
Rofo ; 178(5): 477-83, 2006 May.
Article in German | MEDLINE | ID: mdl-16708322

ABSTRACT

Contrast-enhanced dynamic MR mammography can provide important additional diagnostic information when performed for certain indications. When suspicious lesions are identified on MR mammography and cannot be reproduced using other imaging modalities, a decision must be made as to its management, i. e. further diagnostic work-up. One possibility is the short-term follow-up of such findings, resulting in higher costs and a possible delay in the start of treatment of a malignant lesion. An alternative to a follow-up is an MR-guided intervention. MR-compatible equipment has been developed for this purpose. This includes equipment specialized for percutaneous biopsy and preoperative localization. The following is an overview of the diagnostic value of MR-guided biopsy and preoperative localization including the relevant literature.


Subject(s)
Biopsy/methods , Breast Neoplasms/diagnosis , Breast Neoplasms/pathology , Breast/pathology , Magnetic Resonance Imaging/methods , Biopsy/instrumentation , Contrast Media , Female , Follow-Up Studies , Humans , Image Enhancement , Magnetic Resonance Imaging/instrumentation , Mammography/methods , Preoperative Care , Prone Position , Supine Position , Time Factors , Vacuum
6.
Rofo ; 177(8): 1103-9, 2005 Aug.
Article in German | MEDLINE | ID: mdl-16021542

ABSTRACT

PURPOSE: To evaluate the usefulness of a computer-aided detection (CAD) system in full-field digital mammography in correlation to tumor histology. MATERIAL AND METHODS: A total of 476 patients (226 patients with histologically proven malignant tumors, 250 healthy women) took part in this study. The mammograms were studied retrospectively, using the CAD system Image Checker. For 226 patients digital mammograms in MLO-projection were available. For 186 of these patients the CC-projection was also available. CAD markers that correlated with histologically proven carcinomas were considered to be true-positive markers. All other CAD markers were considered to be false-positive. Histologically proven carcinomas without markers were false-negative results. The dependence of the CAD markers placement upon the different carcinoma histologies was studied using the Chi-square test. RESULTS: No significant difference could be proven for the detectability of malignant breast lesions of different histologic types. For the detectability of ductal carcinoma in situ (DCIS), invasive ductal carcinoma (IDC), invasive lobular carcinoma (ILC), lobular carcinoma in situ (LCIS), tubular carcinoma and ductulo-lobular carcinoma, the true positives were 71.1 %, 75 %, 70.7 %, 70 %, 60 % and 80 %, respectively, in the MLO projection and 83.9 %, 75.9 %, 81.8 %, 77.8 %, 87.5 % and 33.3 %, respectively, in the CC projection. There was an average of 0.5 false-positive markers per mammographic image. CONCLUSION: The histologic type of carcinoma seems to have no influence on detectability when using the CAD system. The high rate of false-positive markers shows, however, the limited specificity of the CAD system and that improvements are necessary.


Subject(s)
Artificial Intelligence , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Mammography/methods , Radiographic Image Enhancement/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Adult , Aged , Female , Humans , Middle Aged , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity , Statistics as Topic
7.
Eur Radiol ; 15(5): 1027-36, 2005 May.
Article in English | MEDLINE | ID: mdl-15856253

ABSTRACT

The Breast Imaging Reporting and Data System (BI-RADS) of the American College of Radiology (ACR) is a tool created to reduce variability in the terminology used in mammographic reports. An illustration of mammographic examples from our institution interpreted according to the BI-RADS lexicon of the American College of Radiology (ACR) is presented. A literature review concerning the usefulness and limitations of the BI-RADS lexicon is given.


Subject(s)
Breast Diseases/diagnostic imaging , Mammography/standards , Radiology Information Systems/standards , Terminology as Topic , Female , Humans
8.
Clin Radiol ; 60(2): 196-206, 2005 Feb.
Article in English | MEDLINE | ID: mdl-15664574

ABSTRACT

AIM: To evaluate prospectively the influence of pulmonary nodule characteristics on detection performances of a computer-aided diagnosis (CAD) tool and experienced chest radiologists using multislice CT (MSCT). MATERIALS AND METHODS: MSCT scans of 20 consecutive patients were evaluated by a CAD system and two independent chest radiologists for presence of pulmonary nodules. Nodule size, position, margin, matrix characteristics, vascular and pleural attachments and reader confidence were recorded and data compared with an independent standard of reference. Statistical analysis for predictors influencing nodule detection or reader performance included chi-squared, retrograde stepwise conditional logistic regression with odds ratios and nodule detection proportion estimates (DPE), and ROC analysis. RESULTS: For 135 nodules, detection rates for CAD and readers were 76.3, 52.6 and 52.6%, respectively; false-positive rates were 0.55, 0.25 and 0.15 per examination, respectively. In consensus with CAD the reader detection rate increased to 93.3%, and the false-positive rate dropped to 0.1/scan. DPEs for nodules < or = 5 mm were significantly higher for ICAD than for the readers (p < 0.05). Absence of vascular attachment was the only significant predictor of nodule detection by CAD (p = 0.0006-0.008). There were no predictors of nodule detection for reader consensus with CAD. In contrast, vascular attachment predicted nodule detection by the readers (p = 0.0001-0.003). Reader sensitivity was higher for nodules with vascular attachment than for unattached nodules (sensitivities 0.768 and 0.369; 95% confidence intervals = 0.651-0.861 and 0.253-0.498, respectively). CONCLUSION: CAD increases nodule detection rates, decreases false-positive rates and compensates for deficient reader performance in detection of smallest lesions and of nodules without vascular attachment.


Subject(s)
Solitary Pulmonary Nodule/diagnostic imaging , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Humans , Middle Aged , Prospective Studies , Reference Standards , Sensitivity and Specificity , Solitary Pulmonary Nodule/pathology , Tomography, X-Ray Computed/standards
9.
Clin Imaging ; 28(3): 166-9, 2004.
Article in English | MEDLINE | ID: mdl-15158219

ABSTRACT

Sarcoidosis is a multisystemic granulomatous disease of unknown etiology. Neurologic manifestations occur usually as a part of the spectrum of the systemic disease. The aim of this retrospective study was to evaluate the role of magnetic resonance imaging (MRI) in the diagnosis of patients with neurosarcoidosis (NS). Seven patients with sarcoidosis could be included into the study. All patients had neurological symptoms and were evaluated with MRI revealing a wide spectrum of findings: periventricular and white matter lesions, multiple or solitary supra- and infratentorial brain lesions, leptomeningeal enhancement, involvement of brain nerves and intramedullar lesions. These findings are not specific for sarcoidosis and must be considered with the clinical course of the patient in arriving at the correct diagnosis.


Subject(s)
Brain Diseases/diagnosis , Magnetic Resonance Imaging , Sarcoidosis/diagnosis , Adolescent , Adult , Arachnoid/pathology , Cerebellar Diseases/diagnosis , Cerebral Ventricles/pathology , Cranial Nerve Diseases/diagnosis , Female , Humans , Male , Medulla Oblongata/pathology , Pia Mater/pathology , Retrospective Studies
10.
Rofo ; 175(11): 1490-5, 2003 Nov.
Article in German | MEDLINE | ID: mdl-14610699

ABSTRACT

AIM: This study determined the diagnostic performance of ECG-gated MSCT in comparison with conventional MSCT. MATERIALS AND METHODS: Forty-five consecutive patients prospectively underwent ECG-gated (group 1, n = 23) or non-ECG-gated (group 2, n = 22) 8-slice MSCT of the pulmonary arteries. Image data were interactively evaluated by three independent chest radiologists with respect to the presence of emboli at different arterial levels, and with regard to cardiac motion artefacts. Consensus reading by two experienced chest radiologists served as diagnostic gold standard. ROC analysis was carried out for the different vascular sections. RESULTS: Twenty-five patients (56 %) were diagnosed to have pulmonary embolism (13 from group 1, 12 from group 2). Cardiac motion artefacts were significantly more frequent in group 2 (70 % in group 2 versus 13 % in group 1, p < 0.05). There was no significant difference between the two groups in the overall sensitivities (0.92 vs. 0.95) and specificities (0.92 vs. 0.98) or in sensitivities and specificities at any assessed pulmonary arterial level. CONCLUSION: ECG-gated MSCT pulmonary angiography does not significantly influence the diagnostic performance of MSCT in these patients. Therefore no recommendation for routine clinical practice can be given.


Subject(s)
Gated Blood-Pool Imaging/methods , Pulmonary Embolism/diagnostic imaging , Adolescent , Adult , Aged , Aged, 80 and over , Artifacts , Electrocardiography , Female , Humans , Male , Middle Aged , Radiography , Reproducibility of Results , Retrospective Studies
11.
Clin Radiol ; 58(11): 862-8, 2003 Nov.
Article in English | MEDLINE | ID: mdl-14581010

ABSTRACT

AIM: The purpose of this study was to determine the feasibility of echocardiogram (ECG)-gated multi-slice CT angiography (MCTA) in patients with clinical suspicion of acute venous thromboembolism (VTE), to investigate the effect of ECG-gating on cardiac motion artefacts, and to determine the diagnostic reader agreement of ECG-gated MCTA in comparison with conventional MCTA. MATERIALS AND METHODS: Forty-eight consecutive patients were prospectively enrolled and randomly underwent ECG-gated (n=25, group 1) or non-ECG-gated (n=23, group 2) eight-slice pulmonary MCTA. Image data were evaluated by three independent chest radiologists with respect to the presence or absence of emboli at different arterial levels (main, lobar, segmental, and subsegmental arteries), and with regard to cardiac motion artefacts. Statistical tests used to calculate inter-observer agreement were weighted kappa statistics, extended kappa statistics and confidence indices indicating three-reader agreement accuracy. RESULTS: Twenty-seven patients (56.3%) were diagnosed to have pulmonary embolism (13 from group 1, 14 from group 2). Cardiac motion artefacts were significantly more frequent in group 2 (70% in group 2 versus 13% in group 1, p=0.0001). The overall diagnostic agreement was excellent with both MCTA techniques (three-reader confidence index for all vascular territories: 0.76 and 0.84 for groups 1 and 2, respectively (extended kappa=0.69 and 0.78, respectively); three-reader confidence index for diagnosis of VTE: 0.94 and 0.85 for groups 1 and 2, respectively (extended kappa=0.91 and 0.73, respectively), weighted kappa=0.81-0.83 and 0.92-0.95 for groups 1 and 2, respectively, and did not differ significantly between the two groups. In addition there was no significant difference of inter-observer agreement in either group at any assessed pulmonary arterial level. CONCLUSION: ECG-gated pulmonary MCTA is feasible in patients with clinical suspicion of VTE. However, ECG-gated image acquisition did not influence the diagnostic reader agreement accuracy and inter-observer agreement of MCTA. Hence, it does not appear to be advantageous for the MCTA diagnosis of pulmonary embolism.


Subject(s)
Electrocardiography/methods , Pulmonary Embolism/diagnosis , Tomography, Spiral Computed/methods , Acute Disease , Adolescent , Adult , Aged , Aged, 80 and over , Feasibility Studies , Female , Heart/physiopathology , Humans , Lung/blood supply , Male , Middle Aged , Movement , Observer Variation , Prospective Studies , Pulmonary Embolism/diagnostic imaging , Pulmonary Embolism/physiopathology , Single-Blind Method , Thromboembolism/diagnosis , Thromboembolism/diagnostic imaging , Thromboembolism/physiopathology
12.
Rofo ; 175(9): 1239-43, 2003 Sep.
Article in German | MEDLINE | ID: mdl-12964080

ABSTRACT

PURPOSE: To evaluate the diagnostic value of a higher concentrated contrast medium (gadobutrol) for contrast-enhanced MRA of the hepatic arteries and portovenous system. MATERIALS AND METHODS: The examinations were performed on a 1.5-Tesla whole body imaging system (Magnetom Symphony Quantum, Siemens) with a 30-mTesla/m gradient field strength using a phased-array body coil. A 3D FLASH sequence (TR/TE/FA 3.88 ms/1.44 ms/25(3)) was used imaging the hepatic arteries and portovenous system after determination of the circulation time. The study included 50 patients, with 25 patients (group 1) injected with 0.2 mmol Gd-GTPA/kg body weight and 25 patients (group 2) injected with 0.1 mmol gadobutrol/kg body weight. The signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) were calculated for both groups. The image quality was graded by three radiologists on a 5-point scale. RESULTS: The highest SNR was measured in group 1, with no statistically significant differences of the SNR in the abdominal aortal, coeliac trunk and common hepatic artery. CNR was also similar in both groups. Likewise, portal, superior mesenteric and splenic veins showed no statistically significant differences. All cases were found to have a good image quality. CONCLUSION: For MRA of the hepatic arteries and the portal veins, the higher concentrated Gd-DTPA contrast medium gadobutrol can be used at half the dosage recommended for the standard Gd-DTPA contrast medium.


Subject(s)
Contrast Media , Hepatic Artery/anatomy & histology , Organometallic Compounds , Portal Vein/anatomy & histology , Adult , Aged , Contrast Media/administration & dosage , Data Interpretation, Statistical , Female , Gadolinium/administration & dosage , Gadolinium DTPA/administration & dosage , Humans , Liver Transplantation , Magnetic Resonance Angiography , Male , Middle Aged , Organometallic Compounds/administration & dosage
13.
Clin Imaging ; 27(5): 346-50, 2003.
Article in English | MEDLINE | ID: mdl-12932688

ABSTRACT

OBJECTIVE: Müllerian duct anomalies (MDAs) result from nondevelopment or nonfusion of the müllerian ducts and occur in 1-5% of women. Accurate diagnosis of the various subtypes is of great importance as MDAs are frequently associated with a broad variety of clinical symptoms. Recently, evidence arose that MRI might play a major role in diagnosis of MDAs. We present four cases of diverse subtypes of MDAs and the corresponding MRI findings. MATERIALS AND METHODS: Patients (n = 4) with clinical suspicion of MDAs were examined with MRI. Coronal and transaxial T1- and T2-weighted images were acquired. Diagnosis was made and patients were grouped according to the American Fertility Society's classification. Patients underwent laparoscopy or laparotomy in order to confirm the diagnosis. RESULTS: MRI revealed MDAs in all patients. In detail, one patient was diagnosed with hypoplastic uterus, one with unicornuate uterus with a noncommunicating rudimentary horn, one with bicornuate uterus bicollis with a double vagina and one with septate uterus. MRI diagnosis was correct in all cases, as confirmed by subsequent surgical intervention. CONCLUSION: MRI is a valuable tool in diagnosis of MDA subtypes. Its use will help to spare patients mutilating surgery and to prevent pregnancy-associated complications.


Subject(s)
Magnetic Resonance Imaging , Mullerian Ducts/abnormalities , Uterus/abnormalities , Vagina/abnormalities , Adult , Female , Humans , Prospective Studies
14.
Br J Radiol ; 76(907): 478-82, 2003 Jul.
Article in English | MEDLINE | ID: mdl-12857708

ABSTRACT

The aim of this study was to evaluate the potential for radiation dose reduction by using other beam qualities in full-field digital mammography (FFDM) compared with screen-film mammography (SFM). FFDM was performed using an amorphous silicon detector with a caesium iodide scintillator layer (Senographe 2000D, GE, Milwaukee, USA). SFM was performed using a state-of-the-art conventional system (Senographe DMR, GE, Milwaukee, USA) with a dedicated screen-film combination. An anthropomorphic breast phantom with superimposed microcalcifications (50-200 microm) was used to evaluate the detectability of microcalcifications. Contact mammograms and magnification views (m=1.8) performed with both the digital and the screen-film system were compared. Images were exposed automatically. Molybdenum/Molybdenum (Mo/Mo) anode-filter combination, 28 kVp and 63 mAs were selected by the automatic optimization of parameters (AOP) of the conventional system. This exposure protocol (protocol A) was also used as baseline for the digital system. Dose reduction in digital mammography was achieved by using protocol B with Mo/Rh and 31 kVp and protocol C with Rh/Rh and 32 kVp. The detectability of microcalcifications was assessed by 3 experienced readers with a confidence level ranging from 1 to 5. A receiver operating characteristic (ROC) analysis was performed. In protocol A the area under the ROC-curve (A(z)) for contact views performed by the screen-film system was 0.64 and for those performed with the FFDM system 0.68. The A(z) values were 0.74 in protocol B and 0.65 in protocol C for the digital system. For the conventional and digital magnification views A(z) values were 0.71 and 0.79, respectively. For protocol B the A(z) value was 0.81 and for protocol C it was 0.76. There is no statistically significant difference in the A(z) values for the different protocols in digital mammography and no significant difference from the screen-film system. A potential for dose reduction by using other beam qualities seems to be possible with this digital system.


Subject(s)
Breast Neoplasms/diagnostic imaging , Mammography/methods , Phantoms, Imaging , Radiographic Image Enhancement/methods , Anthropometry , Calcinosis/diagnostic imaging , Female , Humans , ROC Curve , Radiation Dosage , X-Ray Intensifying Screens
15.
Rofo ; 175(5): 635-9, 2003 May.
Article in German | MEDLINE | ID: mdl-12743855

ABSTRACT

PURPOSE: To investigate the value of different postprocessing algorithms for multislice spiral CT (MSCT) in diagnosing acute pulmonary embolism. MATERIALS AND METHODS: Forty-eight patients with suspected pulmonary embolism prospectively underwent MSCT using an 8-slice spiral CT. Using a confidence level on a three-point scale, three radiologists reviewed 2-mm and 5-mm axial slices, 5-mm and 10-mm axial maximum intensity projections (MIP) and 2-mm coronal slices as well as interactively generated multiplanar reformatted images. A subsequent consensus reading of the primary 1.25-mm axial slices served as gold standard. ROC analysis was applied to the various vascular sections. RESULTS: The ROC analysis revealed a higher diagnostic accuracy of the 2-mm axial sections as compared to the 5-mm axial slices (Az = [0.988;0.976] vs. Az = [0.988;0.802]). Coronal and multiplanar reformations also showed excellent diagnostic accuracy (Az = [0.972;0.949] and Az = [0.997;0.951], respectively) and were significantly superior to the 5-mm axial slices through the segmental and subsegmental arteries (p=0.05). MIP showed the weakest diagnostic accuracy (Az = [0.967;0.802] for 5-mm MIP; Az = [0.879;0.781] for 10-mm MIP). CONCLUSION: Thin axial slices as well as coronal and multiplanar reformations are superior to thick axial slices in the diagnosis of acute pulmonary embolism. MIP is not suited for accurate diagnosis of pulmonary embolic disease.


Subject(s)
Image Processing, Computer-Assisted/methods , Pulmonary Embolism/diagnostic imaging , Radiographic Image Enhancement/methods , Tomography, Spiral Computed/methods , Acute Disease , Adult , Aged , Female , Humans , Male , Middle Aged , Observer Variation , ROC Curve , Sensitivity and Specificity
16.
Eur Radiol ; 12(12): 3015-7, 2002 Dec.
Article in English | MEDLINE | ID: mdl-12439584

ABSTRACT

For the first time, full-field digital mammography (FFDM) allows computer-aided detection (CAD) analysis of directly acquired digital image data. The purpose of this study was to evaluate a CAD system in patients with histologically correlated breast cancer depicted with FFDM. Sixty-three cases of histologically proven breast cancer detected with FFDM (Senographe 2000D, GE Medical Systems, Buc, France) were analyzed using a CAD system (Image Checker V2.3, R2 Technology, Los Altos, Calif.). Fourteen of these malignancies were characterized as microcalcifications, 37 as masses, and 12 as both. The mammographic findings were categorized as BI-RADS 3 (n=5), BI-RADS 4 (n=17) and BI-RADS 5 (n=40). The sensitivity for malignant lesions and the rate of false-positive marks per image were calculated. The sensitivity and its 95% confidence interval (CI) were estimated. The sensitivity of the CAD R2 system in breast cancer seen on FFDM was 89% for microcalcifications [CI(95%)=(70%; 98%)] and 81% for masses [CI(95%)=(67%; 91%)]. As expected, the detection rate was higher in lesions categorized as BI-RADS 5 (37 of 40) compared with lesions categorized as BI-RADS 4 (11 of 17). In the group categorized as BI-RADS 3 the detection rate was 4 of 5 lesions; however, this group was very small. The rate of false-positive marks was 0.35 microcalcification marks/image and 0.26 mass marks/image. The overall rate of false-positive marks was 0.61 per image. CAD based on FFDM provides an optimized work flow. Results are equivalent to the results reported for CAD analysis of secondarily digitized image data. Sensitivity for microcalcifications is acceptable and for masses is low. The number of false-positive marks per image should be reduced.


Subject(s)
Mammography/methods , Radiographic Image Enhancement , Radiographic Image Interpretation, Computer-Assisted , Breast Neoplasms/diagnosis , Calcinosis/diagnosis , Carcinoma/diagnosis , False Positive Reactions , Female , Humans , Magnetic Resonance Imaging , Sensitivity and Specificity , Women's Health
17.
Eur Radiol ; 12(11): 2679-83, 2002 Nov.
Article in English | MEDLINE | ID: mdl-12386757

ABSTRACT

The goal of this prospective study was to compare a full-field digital mammography system (FFDM) to a conventional screen-film mammography system (SFM) for the detection and characterization of microcalcifications. Fifty-five patients with 57 isolated microcalcification clusters were examined using a FFDM system (Senographe 2000D, GE Medical Systems, Milwaukee, Wis.) and a SFM system (Senographe DMR, GE Medical Systems, Milwaukee, Wis.). A conventional screen-film mammogram and a digital contact mammogram were obtained of each cluster. The image quality and the number of calcification particles were evaluated, and a characterization (BI-RADS 1-5) of microcalcifications was given by four experienced readers. Histopathology revealed 16 benign lesions (sclerosing adenosis, dysplasia, hamartoma, radial scar) in 15 patients and 21 malignant tumors (in situ carcinoma, invasive carcinoma) in 20 patients. Twenty patients had benign changes verified by long-term follow-up. Image quality of FFDM was assessed as superior to SFM in more than 50% of the cases. The FFDM showed more calcifications in 41% of all cases. Sensitivity and specificity for FFDM vs SFM were 95.2 vs 91.9% and 41.4 vs 39.3%, respectively. Moreover, FFDM demonstrated a higher diagnostic accuracy (deviation: 0.86 BI-RADS steps) compared with FSM (deviation 0.93 BI-RADS steps). The FFDM system with a 100- micro m pixel size provides better image quality than SFM in patients with mammographic microcalcifications. The FFDM has a higher sensitivity and a higher reliability in characterizing microcalcifications.


Subject(s)
Breast Neoplasms/diagnostic imaging , Calcinosis/diagnostic imaging , Mammography/methods , Female , Humans , Middle Aged , Prospective Studies , Radiographic Image Enhancement , Retrospective Studies , Sensitivity and Specificity , X-Ray Intensifying Screens
18.
Eur Radiol ; 12(9): 2188-91, 2002 Sep.
Article in English | MEDLINE | ID: mdl-12195468

ABSTRACT

The objective of this study was a comparison of a full-field digital mammography (FFDM) system and a conventional screen-film mammography (SFM) system with respect to the detectability of simulated small masses and microcalcifications in the magnification mode. All images were obtained using 1.8 times magnification. The FFDM images were obtained at radiation dose levels of 1.39, 1.0, 0.7, 0.49 and 0.24 times that of the SFM images. A contrast-detail phantom was used to compare the detection of simulated lesions using a four alternative forced-choice reader study with three readers. The correct observation ratio (COR) was calculated as the fraction of correctly identified lesions to the total number of simulated lesions. Soft-copy reading was performed for all digital images. Direct magnification images acquired with the digital system showed a lower object contrast threshold than those acquired with the conventional system. For equal radiation dose, the digital system provided a significantly increased COR (0.95) compared with the screen-film system (0.82). For simulated microcalcifications, the corresponding difference was 0.90 to 0.72. The digital system allowed equal detection to screen-film at 40% of the radiation dose used for screen film. Digital magnification images are superior to screen-film magnification images for the detection of simulated small masses and microcalcifications even at a lower radiation dose.


Subject(s)
Breast Diseases/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Calcinosis/diagnostic imaging , Mammography/methods , Female , Humans , Phantoms, Imaging , Radiation Dosage , Radiographic Image Enhancement , Radiographic Magnification , X-Ray Intensifying Screens
19.
Eur Radiol ; 12(7): 1697-702, 2002 Jul.
Article in English | MEDLINE | ID: mdl-12111060

ABSTRACT

The objective of this study was to compare screen-film mammography (SFM) to full-field digital mammography (FFDM) regarding image quality as well as detectability and characterization of lesions using equivalent images of the same patient acquired with both systems. Two mammography units were used, one with a screen-film system (Senographe DMR) and the other with a digital detector (Senographe 2000D, both GEMS). Screen-film and digital mammograms were performed on 55 patients with cytologically or histologically proven tumors on the same day. Together with these, 75 digital mammograms of patients without tumor and the corresponding previous screen-film mammograms not older than 1.5 years were reviewed by three observers in a random order. Contrast, exposure, and the presence of artifacts were evaluated. Different details, such as the skin, the retromamillary region, and the parenchymal structures, were judged according to a three-point ranking scale. Finally, the detectability of microcalcifications and lesions were compared and correlated to histology. Image contrast was judged to be good in 76%, satisfactory in 20%, and unsatisfactory in 4% of screen-film mammograms. Digital mammograms were judged to be good in 99% and unsatisfactory in 1% of cases. Improper exposure of screen-film system occurred in 18% (10% overexposed and 8% underexposed). Digital mammograms were improperly exposed in 4% of all cases but were of acceptable quality after post-processing. Artifacts, most of them of no significance, were found in 78% of screen-film and in none of the digital mammograms. Different anatomical regions, such as the skin, the retromamillary region, and dense parenchymal areas, were better visualized in digital than in screen-film mammography. All malignant tumors were seen by the three radiologists; however, digital mammograms allowed a better characterization of these lesions to the Breast Imaging Reporting and Data System (BI-RADS;) [corrected] categories (FFDM better than SFM in 23 of 165 vs 9 of 165 judged cases in SFM). In conclusion, digital mammography offers a consistent, high image quality in combination with a better contrast and without artifacts. Lesion detection in digital images was equal to that in screen-film images; however, categorization of the lesions to the BI-RADS classification was slightly better.


Subject(s)
Mammography , Radiographic Image Enhancement , X-Ray Intensifying Screens , Adult , Aged , Aged, 80 and over , Artifacts , Breast Neoplasms/diagnostic imaging , Female , Humans , Mammography/methods , Middle Aged
20.
Eur Radiol ; 12(8): 2107-11, 2002 Aug.
Article in English | MEDLINE | ID: mdl-12136331

ABSTRACT

Our objective was to compare a single-slice CT (SS-CT) scanner with a multi-slice CT (MS-CT) scanner in the depiction of osseous anatomic structures and fractures of the upper cervical spine. Two cervical spine specimens with artificial trauma were scanned with a SS-CT scanner (HighSpeed, CT/i, GE, Milwaukee, Wis.) by using various collimations (1, 3, 5 mm) and pitch factors (1, 1.5, 2, 3) and a four-slice helical CT scanner (LightSpeed, QX/i, GE, Milwaukee, Wis.) by using various table speeds ranging from 3.75 to 15 mm/rotation for a pitch of 0.75 and from 7.5 to 30 mm/rotation for a pitch of 1.5. Images were reconstructed with an interval of 1 mm. Sagittal and coronal multiplanar reconstructions of the primary and reconstructed data set were performed. For MS-CT a tube current resulting in equivalent image noise as with SS-CT was used. All images were judged by two observers using a 4-point scale. The best image quality for SS-CT was achieved with the smallest slice thickness (1 mm) and a pitch smaller than 2 resulting in a table speed of up to 2 mm per gantry rotation (4 points). A reduction of the slice thickness rather than of the table speed proved to be beneficial at MS-CT. Therefore, the optimal scan protocol in MS-CT included a slice thickness of 1.25 mm with a table speed of 7.5 mm/360 degrees using a pitch of 1.5 (4 points), resulting in a faster scan time than when a pitch of 0.75 (4 points) was used. This study indicates that MS-CT could provide equivalent image quality at approximately four times the volume coverage speed of SS-CT.


Subject(s)
Cervical Vertebrae/diagnostic imaging , Spinal Fractures/diagnostic imaging , Tomography, X-Ray Computed/methods , Humans , Image Processing, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL