Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
J Vasc Surg ; 75(1): 177-185.e1, 2022 01.
Article in English | MEDLINE | ID: mdl-34302937

ABSTRACT

OBJECTIVE/BACKGROUND: Retrograde recanalizations gained increasing recognition in complex arterial occlusive disease. Re-entry devices are a well-described adjunct for antegrade recanalizations. We present our experience with retrograde, infrainguinal recanalizations using the Outback re-entry catheter in challenging chronic total occlusions. METHODS: We report data from a retrospective multicenter registry in complex retrograde recanalizations. Eligibility criteria included retrograde infrainguinal use of the Outback re-entry catheter where both conventional antegrade and retrograde recanalizations had been unsuccessful. Procedural outcomes included technical success (defined as successful wire passage and delivery of adjunctive therapy with <30% residual stenosis), safety (periprocedural complications, eg, bleeding, vessel injury, or occlusion of the artery at the re-entry site, and distal embolizations), and clinical outcome (amputation-free survival and freedom from clinically driven target lesion revascularization [cd-TLR]). RESULTS: Forty-five consecutive patients underwent retrograde, infrainguinal recanalization attempts with the Outback re-entry catheter between February 2015 and August 2020. Thirty (67%) patients had a history of open vascular surgery in the index limb. In four patients, recanalizations were even more challenging due to previous surgical removal and/or ligation of the proximal segment of the superficial femoral artery. The retrograde access site of the Outback catheter was the femoropopliteal segment in 31 (69%) patients and crural vessels in 14 (31%) patients. The re-entry target sites were as follows: common femoral artery in 31 (69%) patients, superficial femoral artery in 9 (20%) patients, popliteal artery in 1 patient, and below-the-knee arteries in 2 patients. In four patients, the needle of the re-entry device was targeted to an inflated balloon, inserted via the antegrade route. The Outback re-entry catheter was placed via a 6-French sheath in 19 (42%) cases and sheathless in 26 (58%) cases. Technical success was achieved in 41 (91%) patients There were two instances of distal embolizations and three bleeding episodes. Amputation-free survival was 100% at 30 days, and after 12 months, freedom from cd-TLR was 95% at 30 days and 75% at 12 months of follow-up. Female sex was an independent predictor for cd-TLR at 12 months of follow-up. CONCLUSIONS: Retrograde use of the Outback re-entry catheter in infrainguinal chronic total occlusions provides an effective and safe endovascular adjunct, when conventional antegrade and retrograde recanalization attempts have failed.


Subject(s)
Angioplasty/instrumentation , Arterial Occlusive Diseases/surgery , Catheterization, Peripheral/instrumentation , Postoperative Complications/epidemiology , Aged , Aged, 80 and over , Angioplasty/adverse effects , Angioplasty/methods , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/methods , Catheters/adverse effects , Female , Femoral Artery/surgery , Follow-Up Studies , Humans , Male , Middle Aged , Popliteal Artery/surgery , Postoperative Complications/etiology , Retrospective Studies , Stents/adverse effects , Treatment Outcome
2.
Vasa ; 50(6): 475-479, 2021 Nov.
Article in English | MEDLINE | ID: mdl-33118474

ABSTRACT

Standard nitinol stents (SNS), with or without drug eluting technology, are an essential tool within the interventional armamentarium in the treatment of patients with peripheral arterial disease. However, they are plagued by a number of limitations: a.) stent fractures, although observed predominately in first-generation stents, do still occur in state-of-the art stent platforms, b.) lack of radial strength, resulting in inadequate stent expansion, c.) kinking up to a complete collapse of the stent, therefore compromising its use in areas of high mechanical stress such as bending zones. In contrast, the interwoven design of the SuperaTM stent, also referred to as "vascular mimetic implant", overcomes all of the above limitations of SNS. Several registries and studies not only confirmed its mechanical superiority (lack of stent fractures etc.) but also demonstrated remarkable clinical performance (patency and freedom from target lesion revascularization), despite its use in challenging lesions (calcification etc.) and territories (popliteal arteries etc.). Increasing confidence in the mechanical properties of the SuperaTM stent platform prompted interventionalists to further "push the limits" of this unique implant. The present article summarizes the clinical data and shows examples of "extreme" applications of this dedicated stent platform.


Subject(s)
Femoral Artery , Peripheral Arterial Disease , Alloys , Humans , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/surgery , Popliteal Artery/diagnostic imaging , Popliteal Artery/surgery , Prosthesis Design , Stents , Treatment Outcome , Vascular Patency
3.
BMC Res Notes ; 7: 431, 2014 Jul 05.
Article in English | MEDLINE | ID: mdl-24996222

ABSTRACT

BACKGROUND: Data on prevalence rates of venous thromboembolism (VTE) in different patient populations are scarce. Most studies on this topic focus on older patients or patients with malignancies, immobilization or thrombophilia. Less is known about the VTE risk profile of non-surgical patients presenting with a variety of medical diseases of differing severity. Aim of the present study was to investigate VTE prevalence in a pospective cohort study of ambulatory medical intensive care unit patients within 24 h after acute admission. METHODS: Prospective cohort study of 102 consecutive patients after acute admission to medical intensive care unit. Ultrasound compression sonography, APACHE-II-Scoring and laboratory examination was performed within 24 hours after admission.Possible determinants of a high risk of VTE were examined. In all patients with a confirmed diagnosis of DVT or suspicion of PE thoracic computer tomography (CT) was performed. RESULTS: VTE was found in 7.8% out of 102 of patients, mean APACHE-II-Score was 14 (mortality risk of about 15%). Thrombus location was femoropopliteal in 5 patients, iliacal in 2 and peroneal in 1 patient. Five VTE patients had concomitant PE (62.5% of VTE, 4.9% of all patients). No predictors of prevalent VTE were identified from univariable regression analysis although relative risk was high in patients with a history of smoking (RR 3.40), immobility (RR 2.50), and elevated D-Dimer levels (RR 3.49). CONCLUSIONS: Prevalent VTE and concomitant PE were frequent in acutely admitted ICU patients.


Subject(s)
Intensive Care Units/statistics & numerical data , Outpatient Clinics, Hospital/statistics & numerical data , Patient Admission/statistics & numerical data , Venous Thrombosis/epidemiology , APACHE , Aged , Aged, 80 and over , Anticoagulants/therapeutic use , Aspirin/therapeutic use , Clopidogrel , Female , Fibrin Fibrinogen Degradation Products/analysis , Germany/epidemiology , Heparin/therapeutic use , Humans , Male , Middle Aged , Platelet Aggregation Inhibitors/therapeutic use , Prevalence , Prospective Studies , Pulmonary Embolism/drug therapy , Pulmonary Embolism/epidemiology , Risk Factors , Ticlopidine/analogs & derivatives , Ticlopidine/therapeutic use , Venous Thromboembolism/drug therapy , Venous Thromboembolism/epidemiology , Venous Thrombosis/drug therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...