Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 87
Filter
1.
Osteoarthritis Cartilage ; 31(2): 249-257, 2023 02.
Article in English | MEDLINE | ID: mdl-36370959

ABSTRACT

OBJECTIVE: To evaluate the multi-vendor multi-site reproducibility of two-dimensional (2D) multi-echo spin-echo (MESE) T2 mapping (product sequences); and to evaluate the longitudinal reproducibility of three-dimensional (3D) magnetization-prepared angle-modulated partitioned k-space spoiled gradient echo snapshots (MAPSS) T1ρ and T2 mapping (research sequences), and 2D MESE T2 mapping, separated by 6 months, in a multi-vendor multi-site setting. METHODS: Phantoms and volunteers (n = 5 from each site, n = 20 in total) were scanned on four 3 T magnetic resonance (MR) systems from four sites and three vendors (Siemens, General Electric, and Phillips). Two traveling volunteers (3 knees) scanned at all 4 sites at baseline and 6-month follow-up. Data was transferred to one site for centralized processing. Coefficients of variation (CVs) were calculated to evaluate reproducibility. RESULTS: For baseline 2D MESE T2 measures, average CV were 0.37-2.45% (intra-site) and 5.96% (inter-site) for phantoms, and 3.15-8.49% (intra-site) and 14.16% (inter-site) for volunteers. For longitudinal phantom data, intra-site CVs were 1.42-3.48% for 3D MAPSS T1ρ, 1.77-3.56% for 3D MAPSS T2, and 1.02-2.54% for 2D MESE T2. For the longitudinal volunteer data, the intra-site CVs were 2.60-4.86% for 3D MAPSS T1ρ, 3.33-7.25% for 3D MAPSS T2, and 3.11-8.77% for 2D MESE T2. CONCLUSION: This study demonstrated excellent intra-site reproducibility of 2D MESE T2 imaging, while its inter-site variation was slightly higher than 3D MAPSS T2 imaging (10.06% as previously reported). This study also showed excellent reproducibility of longitudinal T1ρ and T2 cartilage quantification, in a multi-vendor multi-site setting for both product 2D MESE T2 and 3D MAPSS T1p/T2 research sequences.


Subject(s)
Cartilage, Articular , Magnetic Resonance Imaging , Humans , Reproducibility of Results , Magnetic Resonance Imaging/methods , Phantoms, Imaging
2.
Osteoarthritis Cartilage ; 30(12): 1647-1657, 2022 12.
Article in English | MEDLINE | ID: mdl-36049665

ABSTRACT

OBJECTIVE: To describe the protocol of a multi-vendor, multi-site quantitative MRI study for knee post-traumatic osteoarthritis (PTOA), and to present preliminary results of cartilage degeneration using MR T1ρ and T2 imaging 10 years after anterior cruciate ligament reconstruction (ACLR). DESIGN: This study involves three sites and two MR platforms. The patients are from a nested cohort (termed as Onsite cohort) within the Multicenter Orthopaedic Outcomes Network (MOON) cohort 10 years after ACLR. Phantoms and controls were scanned for evaluating reproducibility. Cartilage was automatically segmented, and T1ρ and T2 were compared between operated, contralateral, and control knees. RESULTS: Sixty-eight ACL-reconstructed patients and 20 healthy controls were included. In phantoms, the intra-site coefficients of variation (CVs) of repeated scans ranged 1.8-2.1% for T1ρ and 1.3-1.7% for T2. The inter-site CVs ranged 1.6-2.1% for T1ρ and 1.1-1.4% for T2. In human subjects, the intra-site scan/rescan CVs ranged 2.2-3.5% for T1ρ and 2.6-4.9% for T2 for the six major compartments. In patients, operated knees showed significantly higher T1ρ and T2 values mainly in medial femoral condyle, medial tibia and trochlear cartilage compared with contralateral knees, and showed significantly higer T1ρ and T2 values in all six compartments compared to healthy control knees. The patient contralateral knees showed higher T1ρ and T2 values mainly in the lateral femoral condyle, lateral tibia, trochlear, and patellar cartilage compared to healthy control knees. CONCLUSION: A platform and workflow with rigorous quality control has been established for a multi-vendor multi-site quantitative MRI study in evaluating PTOA 10 years after ACLR. Our preliminary report suggests significant cartilage matrix changes in both operated and contralateral knees compared with healthy control knees.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament Reconstruction , Cartilage, Articular , Orthopedics , Osteoarthritis , Humans , Anterior Cruciate Ligament Injuries/diagnostic imaging , Anterior Cruciate Ligament Injuries/surgery , Cartilage, Articular/diagnostic imaging , Cartilage, Articular/surgery , Reproducibility of Results , Anterior Cruciate Ligament Reconstruction/methods , Knee Joint/diagnostic imaging , Knee Joint/surgery , Magnetic Resonance Imaging/methods , Osteoarthritis/surgery , Multicenter Studies as Topic
3.
Osteoarthritis Cartilage ; 28(12): 1539-1550, 2020 12.
Article in English | MEDLINE | ID: mdl-32739341

ABSTRACT

OBJECTIVE: To develop 3D T1ρ and T2 imaging based on the same sequence structure on MR systems from multiple vendors, and to evaluate intra-site repeatability and inter-site inter-vendor reproducibility of T1ρ and T2 measurements of knee cartilage. METHODS: 3D magnetization-prepared angle-modulated partitioned k-space spoiled gradient echo snapshots (3D MAPSS) were implemented on MR systems from Siemens, GE and Philips. Phantom and human subject data were collected at four sites using 3T MR systems from the three vendors with harmonized protocols. Phantom data were collected by means of different positioning of the coil. Volunteers were scanned and rescanned after repositioning. Two traveling volunteers were scanned at all sites. Data were transferred to one site for centralized processing. RESULTS: Intra-site average coefficient of variations (CVs) ranged from 1.09% to 3.05% for T1ρ and 1.78-3.30% for T2 in phantoms, and 1.60-3.93% for T1ρ and 1.44-4.08% for T2 in volunteers. Inter-site average CVs were 5.23% and 6.45% for MAPSS T1ρ and T2, respectively in phantoms, and 8.14% and 10.06% for MAPSS T1ρ and T2, respectively, In volunteers. CONCLUSION: This study showed promising results of multi-site, multi-vendor reproducibility of T1ρ and T2 values in knee cartilage. These quantitative measures may be applied in large-scale multi-site, multi-vendor trials with controlled sequence structure and scan parameters and centralized data processing.


Subject(s)
Cartilage, Articular/diagnostic imaging , Knee Joint/diagnostic imaging , Magnetic Resonance Imaging/methods , Humans , Image Processing, Computer-Assisted , Phantoms, Imaging , Reproducibility of Results
4.
AJNR Am J Neuroradiol ; 41(4): 591-597, 2020 04.
Article in English | MEDLINE | ID: mdl-32217554

ABSTRACT

BACKGROUND AND PURPOSE: NeuroQuant is an FDA-approved software that performs automated MR imaging quantitative volumetric analysis. This study aimed to compare the accuracy of NeuroQuant analysis with visual MR imaging analysis by neuroradiologists with expertise in epilepsy in identifying hippocampal sclerosis. MATERIALS AND METHODS: We reviewed 144 adult patients who underwent presurgical evaluation for temporal lobe epilepsy. The reference standard for hippocampal sclerosis was defined by having hippocampal sclerosis on pathology (n = 61) or not having hippocampal sclerosis on pathology (n = 83). Sensitivities, specificities, positive predictive values, and negative predictive values were compared between NeuroQuant analysis and visual MR imaging analysis by using a McNemar paired test of proportions and the Bayes theorem. RESULTS: NeuroQuant analysis had a similar specificity to neuroradiologist visual MR imaging analysis (90.4% versus 91.6%; P = .99) but a lower sensitivity (69.0% versus 93.0%, P < .001). The positive predictive value of NeuroQuant analysis was comparable with visual MR imaging analysis (84.0% versus 89.1%), whereas the negative predictive value was not comparable (79.8% versus 95.0%). CONCLUSIONS: Visual MR imaging analysis by a neuroradiologist with expertise in epilepsy had a higher sensitivity than did NeuroQuant analysis, likely due to the inability of NeuroQuant to evaluate changes in hippocampal T2 signal or architecture. Given that there was no significant difference in specificity between NeuroQuant analysis and visual MR imaging analysis, NeuroQuant can be a valuable tool when the results are positive, particularly in centers that lack neuroradiologists with expertise in epilepsy, to help identify and refer candidates for temporal lobe epilepsy resection. In contrast, a negative test could justify a case referral for further evaluation to ensure that false-negatives are detected.


Subject(s)
Epilepsy, Temporal Lobe/diagnostic imaging , Hippocampus/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Neuroimaging/methods , Software , Adult , Bayes Theorem , Epilepsy, Temporal Lobe/pathology , Female , Hippocampus/pathology , Humans , Male , Middle Aged , Radiologists , Sclerosis/diagnostic imaging , Sclerosis/pathology , Sensitivity and Specificity
5.
Connect Tissue Res ; 60(6): 597-610, 2019 11.
Article in English | MEDLINE | ID: mdl-31020864

ABSTRACT

Purpose: There is a clinical need to better characterize tissue sources being used for stem cell therapies. This study focuses on comparison of cells and connective tissue progenitors (CTPs) derived from native human infrapatellar fatpad (IPFP), synovium (SYN), and periosteum (PERI). Materials and Methods: IPFP, SYN, PERI were harvested from twenty-eight patients undergoing arthroplasty. CTPs were quantitatively characterized using automated colony-forming-unit assay to compare total nucleated cell concentration-[Cell], cells/mg; prevalence-(PCTP), CTPs/million nucleated cells; CTP concentration-[CTP], CTPs/mg; proliferation and differentiation potential; and correlate outcomes with patient's age and gender. Results: [Cell] did not differ between IPFP, SYN, and PERI. PCTP was influenced by age and gender: patients >60 years, IPFP and SYN had higher PCTP than PERI (p < 0.001) and females had higher PCTP in IPFP (p < 0.001) and SYN (p = 0.001) than PERI. [CTP] was influenced by age: patients <50 years, SYN (p = 0.0165) and PERI (p < 0.001) had higher [CTP] than IPFP; patients between 60 and 69 years, SYN (p < 0.001) had higher [CTP] than PERI; patients >70 years, IPFP (p = 0.006) had higher [CTP] than PERI. In patients >60 years, proliferation potential of CTPs differed significantly (SYN>IPFP>PERI); however, differentiation potentials were comparable between all three tissue sources. Conclusion: SYN and IPFP may serve as a preferred tissue source for patients >60 years, and PERI along with SYN and IPFP may serve as a preferred tissue source for patients <60 years for cartilage repair. However, the heterogeneity among the CTPs in any given tissue source suggests performance-based selection might be useful to optimize cell-sourcing strategies to improve efficacy of cellular therapies for cartilage repair.


Subject(s)
Adipose Tissue/metabolism , Chondrogenesis , Patella/metabolism , Periosteum/metabolism , Stem Cells/metabolism , Synovial Membrane/metabolism , Adipose Tissue/pathology , Adult , Aged , Aged, 80 and over , Cartilage/injuries , Cartilage/metabolism , Cartilage/pathology , Cell- and Tissue-Based Therapy , Female , Humans , Male , Middle Aged , Patella/pathology , Periosteum/pathology , Stem Cells/pathology , Synovial Membrane/pathology
6.
J Bone Joint Surg Am ; 100(20): 1771-1780, 2018 Oct 17.
Article in English | MEDLINE | ID: mdl-30334888

ABSTRACT

BACKGROUND: Current decisions on cellular therapies for osteoarthritis are based primarily on clinical experience or on assumptions about preferred cell sourcing. They have not been informed by rigorous standardized measurements of the chondrogenic connective-tissue progenitors (CTP-Cs) or their intrinsic diversity of chondrogenic potential. The goal of this study was to quantitatively define the CTP-Cs resident in cartilage of different grades of osteoarthritis and to compare their concentration, prevalence, and biological potential. METHODS: Twenty-three patients who had varus malalignment of the knee and were scheduled to undergo elective total knee arthroplasty for idiopathic osteoarthritis and who had grade 1-2 osteoarthritis on the lateral femoral condyle and grade 3-4 osteoarthritis on the medial femoral condyle were recruited for study of the cartilage removed during surgery. CTP-Cs were assayed by a standardized colony-forming-unit assay using automated image-analysis software based on ASTM standard test method F2944-12. RESULTS: Cell concentration was significantly greater (p < 0.001) in grade 3-4 cartilage than in grade 1-2 cartilage. The prevalence of CTP-Cs varied widely, but it trended lower in grade 3-4 cartilage than in grade 1-2 samples (p = 0.078). The biological performance of CTP-Cs from grade 1-2 and grade 3-4 cartilage was comparable. Increased cell concentration was a significant predictor of decreased CTP-C prevalence (p = 0.002). CONCLUSIONS: Although grade 3-4 cartilage showed fewer CTP-Cs than grade 1-2 cartilage, the range of biological performance was comparable, which suggests that either may be used as a source for potent CTP-Cs. However, the biological reason for the heterogeneity of CTP-Cs in cartilage and the biological implications of that heterogeneity are not well understood and require further study. CLINICAL RELEVANCE: In order to improve the efficacy of cartilage cell therapy procedures, it is key to characterize the quality and quantity of the cells and progenitors being administered. Additionally, understanding the heterogeneity in order to select appropriate subsets of populations will improve the rigor of decisions concerning cell sourcing and targeting for pharmacological and cellular therapies.


Subject(s)
Cartilage, Articular/cytology , Osteoarthritis, Knee/pathology , Stem Cells/cytology , Adult , Aged , Cell- and Tissue-Based Therapy , Cells, Cultured , Disease Progression , Female , Humans , Knee Joint , Male , Middle Aged
7.
Curr Res Transl Med ; 65(4): 133-139, 2017 11.
Article in English | MEDLINE | ID: mdl-29132902

ABSTRACT

OBJECTIVE: The two main objectives of the study include (1) Test the hypothesis that the lateral femoral condyle (LFC) in patients with primary OA and varus knees undergoing total knee arthroplasty (TKA) can be used as a model to better characterize varying histological features of human OA, (2) Correlate characteristic OA features using the established histopathological scoring systems (HHGS and OARSI) to understand potential histopathological patterns of OA initiation. DESIGN: Two osteochondral specimens (4×4×8mm) were collected from fifty patient's LFC at the time of TKA (total 100 specimens), who presented preserved lateral knee compartment with joint space width>2mm. Three independent readers graded the sections on three different occasions using HHGS and OARSI systems. The correlation between individual parameters of the two scoring systems and their inter- and intra-reader variability, reliability and reproducibility were estimated. RESULTS: All samples in this cohort showed abnormal histopathological features. Total histopathological scores of the LFC ranged from HHGS median=4.6 (range=0 to 11), and OARSI median=5.2 (range=0 to 19.5). The four individual sub-items of HHGS scoring system (structure, cells, safraninO staining, tidemark) were weakly correlated, with the correlation between structure and cellularity being the strongest (r=0.40). Both the scoring systems had similar repeatability and reproducibility coefficients of<21%. CONCLUSIONS: OA changes in the LFC are not confined to any one region, and maybe seen in different regions of cartilage, tidemark, subchondral bone, and/or the marrow space vascularity. These variations may point to the possibility of several potential patterns of initiation in OA.


Subject(s)
Cartilage, Articular/pathology , Knee Joint/pathology , Osteoarthritis, Knee/pathology , Adult , Aged , Aged, 80 and over , Cohort Studies , Disease Progression , Female , Femur/pathology , Histological Techniques , Humans , Male , Middle Aged
8.
Osteoarthritis Cartilage ; 23(4): 581-8, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25559582

ABSTRACT

OBJECTIVE: To identify risk factors for radiographic signs of post-traumatic osteoarthritis (OA) 2-3 years after anterior cruciate ligament (ACL) reconstruction through multivariable analysis of minimum joint space width (mJSW) differences in a specially designed nested cohort. METHODS: A nested cohort within the Multicenter Orthopaedic Outcomes Network (MOON) cohort included 262 patients (148 females, average age 20) injured in sport who underwent ACL reconstruction in a previously uninjured knee, were 35 or younger, and did not have ACL revision or contralateral knee surgery. mJSW on semi-flexed radiographs was measured in the medial compartment using a validated computerized method. A multivariable generalized linear model was constructed to assess mJSW difference between the ACL reconstructed and contralateral control knees while adjusting for potential confounding factors. RESULTS: Unexpectedly, we found the mean mJSW was 0.35 mm wider in ACL reconstructed than in control knees (5.06 mm (95% CI 4.96-5.15 mm) vs 4.71 mm (95% CI 4.62-4.80 mm), P < 0.001). However, ACL reconstructed knees with meniscectomy had narrower mJSW compared to contralateral normal knees by 0.64 mm (95% C.I. 0.38-0.90 mm) (P < 0.001). Age (P < 0.001) and meniscus repair (P = 0.001) were also significantly associated with mJSW difference. CONCLUSION: Semi-flexed radiographs can detect differences in mJSW between ACL reconstructed and contralateral normal knees 2-3 years following ACL reconstruction, and the unexpected wider mJSW in ACL reconstructed knees may represent the earliest manifestation of post-traumatic osteoarthritis and warrants further study.


Subject(s)
Anterior Cruciate Ligament Reconstruction , Athletic Injuries/surgery , Knee Injuries/surgery , Knee Joint/diagnostic imaging , Menisci, Tibial/surgery , Adolescent , Adult , Age Factors , Athletic Injuries/complications , Child , Cohort Studies , Female , Follow-Up Studies , Humans , Knee Injuries/complications , Knee Joint/surgery , Linear Models , Longitudinal Studies , Male , Menisci, Tibial/diagnostic imaging , Osteoarthritis, Knee/epidemiology , Radiography , Risk Factors , Treatment Outcome , Young Adult
9.
Clin Radiol ; 69(12): e538-44, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25291959

ABSTRACT

AIM: To compare radiation dose surrogates [volume CT dose index (CTDIvol), dose-length product (DLP), size-specific dose estimate (SSDE), and effective dose] and image noise in a cohort of patients undergoing hepatocellular carcinoma screening who underwent both single-energy CT (SECT) and dual-energy CT (DECT). MATERIALS AND METHODS: In this institutional review board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study, 74 adults (mean age 59.5 years) underwent 64 section SECT (120 kVp and weight-based reference mAs) and 128 section dual-source DECT (100/Sn 140 kVp and CTDIvol, adjusted to match the CDTIvol of the SECT protocol) on different occasions. Noise levels were measured in the liver, inferior vena cava (IVC), retroperitoneal (RP) fat, and aorta. Generalized linear models were constructed to compare dose and noise, adjusting for effective diameter. RESULTS: The total DLP (1371.11 mGy-cm, SD = 527.91) and effective dose (20.57 mSv, SD = 7.92) with SECT were significantly higher than the DLP (864.84 mGy-cm, SD = 322.10) and effective dose (12.97 mSv, SD = 4.83) with DECT (p < 0.001). The differences between SECT and DECT increased as the patient's effective diameter increased (p < 0.001). Noise levels in the liver (22.4 versus 21.9 HU), IVC (22.3 versus 23.4 HU), and RP fat (23.5 versus 23 HU) were similar for DECT and SECT (p > 0.05) but were significantly lower in the aorta for DECT (25.3 versus 26.4 HU; p = 0.006). CONCLUSION: DECT imaging of the abdomen can achieve noise levels comparable to those seen with SECT imaging without a dose penalty to patients.


Subject(s)
Carcinoma, Hepatocellular/diagnostic imaging , Liver Neoplasms/diagnostic imaging , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Body Burden , Cohort Studies , Female , Humans , Image Processing, Computer-Assisted/methods , Male , Middle Aged
10.
AJNR Am J Neuroradiol ; 32(9): 1624-31, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21835943

ABSTRACT

BACKGROUND AND PURPOSE: Lumbar pedicle marrow hyperintense signal on T2- and STIR-weighted images is not an uncommon finding. We hypothesize that these marrow signal intensity changes and their behavior within the pedicle are associated with clinical symptoms and that their improvement or resolution correlates with clinical improvement. We investigated the prevalence of these pedicle marrow changes, associated morphologic abnormalities, and the relationship to symptoms over time. MATERIALS AND METHODS: Prevalence was evaluated prospectively in 246 patients and retrospectively in 400 patients. To analyze the relationship between changes in signal intensity over time and symptoms, a third group of 30 patients was followed clinically for assessment of pain and functional limitation and with MR studies for 18 months or until signal intensity changes resolved. RESULTS: The prevalence of pedicle marrow hyperintensity on T2 and STIR-weighted sequences was 1.7%. Associated morphologic abnormalities were pars interarticularis and pedicle fractures and degenerative facets. In the longitudinal study, pedicle marrow signal hyperintensity on T2- and STIR-weighted images resolved in 17 patients and persisted in 5 patients. The extent, intensity, and resolution of signal intensity changes significantly related to the degree of functional limitation (P = .01). CONCLUSIONS: Resolution of pedicle marrow hyperintensity on T2 and STIR-weighted images was associated with improved functional testing and a trend toward decreased pain.


Subject(s)
Bone Marrow/pathology , Low Back Pain/epidemiology , Low Back Pain/pathology , Magnetic Resonance Imaging/statistics & numerical data , Spondylolysis/epidemiology , Spondylolysis/pathology , Adolescent , Adult , Female , Follow-Up Studies , Humans , Longitudinal Studies , Lumbar Vertebrae/pathology , Magnetic Resonance Imaging/methods , Male , Middle Aged , Prevalence , Prospective Studies , Retrospective Studies , Zygapophyseal Joint/pathology
11.
J Neurointerv Surg ; 1(2): 165-7, 2009 Dec.
Article in English | MEDLINE | ID: mdl-21994290

ABSTRACT

BACKGROUND AND PURPOSE: The impact of the Warfarin and Aspirin for Symptomatic Intracranial Disease (WASID) data is described in combination with the commercial release of the Wingspan stenting system on the frequency of neurointervention for the treatment of symptomatic intracranial atherosclerotic disease (ICAD) in a tertiary care center. METHODS: Endovascular case logs were reviewed from April 2004 to July 2007. The total number of intracranial neurointerventions and the number of neurointerventions (percutaneous transluminal angioplasty alone (PTA) or with stenting (PTAS)) performed for symptomatic ICAD were calculated. The time period evaluated was divided into two equal 19.5-month epochs representing the time periods before and after the availability of the Wingspan system. RESULTS: The frequency of neurointerventions for ICAD increased by 763%, from seven of 354 total cases (2%) to 56 of 367 total cases (15.3%) (p<0.001) after the Wingspan system became available. The increase in intracranial PTAS volume occurred immediately and was stable throughout the "Wingspan era". CONCLUSIONS: The publication of the WASID trial results combined with the availability of the Wingspan stent system led to a marked increase in the frequency of neurointervention for symptomatic ICAD at our institution. The adoption of this technology occurred without direct evidence that PTAS with Wingspan is superior to traditional medical therapy. These findings underscore the need for a randomized trial of stenting and medical therapy for the treatment of this disease process.


Subject(s)
Angioplasty/statistics & numerical data , Aspirin/administration & dosage , Hospitals, Special/statistics & numerical data , Intracranial Arteriosclerosis/drug therapy , Stents/statistics & numerical data , Warfarin/administration & dosage , Anticoagulants/administration & dosage , Combined Modality Therapy , Drug Therapy, Combination , Evidence-Based Medicine/statistics & numerical data , Humans , Intracranial Arteriosclerosis/epidemiology , Neurology , Platelet Aggregation Inhibitors/administration & dosage , Prognosis , Retrospective Studies , Risk Factors
12.
Skeletal Radiol ; 37(9): 797-804, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18551289

ABSTRACT

OBJECTIVE: The aim of this study was to determine if the presence of focal normal bone marrow fat signal within a tumor on magnetic resonance imaging excludes malignancy. MATERIALS AND METHODS: One hundred eighty-four histologically proven tumors with available magnetic resonance imaging (MRI) of the appendicular skeleton and pelvis from 184 patients were collected and reviewed at two separate institutions. There were 111 malignant and 73 benign tumors. Two radiologists at each institution, blinded to the diagnosis, reviewed the MRIs independently and reported the presence or absence of normal marrow fat signal within the tumor based upon T1-weighted imaging without fat suppression and T2-weighted imaging with fat suppression and/or short inversion-time inversion recovery (STIR). Discrepancies were then reviewed in consensus to determine the presence or absence of focal normal marrow signal. For each institution, a Fisher's exact test was used to compare the frequency of focal normal marrow fat signal in benign and malignant tumors. This comparison was performed for each reader, as well as for the consensus reading at each site. Positive and negative predictive values were also calculated for each reader, as well as the consensus reading at each site. Fisher's exact test was also used to compare the frequency of intratumoral fat in benign and malignant lesions for the pooled sample. Bayes theorem was used to calculate the positive and negative predictive values for the pooled consensus data. Ninety-five percent confidence intervals were constructed for the pooled estimates using a bootstrapping algorithm. RESULTS: There was good interobserver reliability of 95.3% and 96.7% at sites 1 and 2, respectively. There were three discrepancies (one malignant and two benign) at site 1 and four discrepancies (two malignant and two benign) at site 2. Reader consensus at site 1 identified normal marrow fat signal within 1 of 50 (2.0%) malignant and three of 14 (21.4%) benign tumors. Findings were statistically significant with a p value of 0.030. The positive predictive value (PPV) and negative predictive value (NPV) at site 1 was 81.7% and 75.0%, respectively. Reader consensus at site 2 identified normal marrow fat signal within three of 61 (4.9%) malignant and 14 of 59 (23.7%) benign tumors. Findings were statistically significant with a calculated p value of 0.004. The PPV and NPV at site 1 was 56.3% and 82.4%, respectively. For the pooled consensus, the frequency of intratumoral fat in benign lesions (17/73, 23.3%) is significantly greater than the frequency in malignant lesions (4/111, 3.6%), p < 0.001. CONCLUSION: The presence of focal normal marrow signal within a tumor is highly suggestive of a benign tumor.


Subject(s)
Adipose Tissue/pathology , Bone Marrow/pathology , Bone Neoplasms/pathology , Magnetic Resonance Imaging/methods , Pelvic Bones/pathology , Algorithms , Bayes Theorem , Female , Humans , Male , Neoplasm Metastasis , Predictive Value of Tests , Reproducibility of Results
13.
AJNR Am J Neuroradiol ; 29(6): 1098-103, 2008 Jun.
Article in English | MEDLINE | ID: mdl-18467522

ABSTRACT

BACKGROUND AND PURPOSE: We conducted a prospective randomized study of patients with acute low back pain and/or radiculopathy to assess the effect of knowledge of diagnostic findings on clinical outcome. The practice of ordering spinal imaging, perhaps unintentionally, includes a large number of patients for whom the imaging test is performed for purposes of reassurance or because of patient expectations. If this rationale is valid, one would expect to see a measurable effect from diagnostic information, per se. MATERIALS AND METHODS: A total of 246 patients with acute (<3 weeks) low back pain (LBP) and/or radiculopathy (150 LBP and 96 radiculopathy patients) were recruited. Patients were randomized using a stratified block design with equal allocation to either the unblinded group (MR imaging results provided within 48 hours) or the blinded group (both patient and physician blinded to MR imaging results.) After the initial MR imaging, patients followed 6 weeks of conservative management. Roland function, visual pain analog, absenteeism, Short Form (SF)-36 Health Status Survey, self-efficacy scores, and Fear Avoidance Questionnaire were completed at presentation; 2, 4, 6, and 8 weeks; and 6, 12, and 24 months. Improvement of Roland score by 50% or more and patient satisfaction assessed by Cherkin symptom satisfaction measure were considered a positive outcome. RESULTS: Clinical outcome at 6 weeks was similar for unblinded and blinded patients. Self-efficacy, fear avoidance beliefs, and the SF-36 subscales were similar over time for blinded and unblinded patients, except for the general health subscale on the SF-36. General health of the blinded group improved more than for the unblinded group (P = .008). CONCLUSIONS: Patient knowledge of imaging findings do not alter outcome and are associated with a lesser sense of well-being.


Subject(s)
Low Back Pain/diagnosis , Low Back Pain/epidemiology , Outcome Assessment, Health Care/statistics & numerical data , Patient Satisfaction/statistics & numerical data , Practice Patterns, Physicians'/statistics & numerical data , Radiculopathy/diagnosis , Radiculopathy/epidemiology , Acute Disease , Adult , Female , Humans , Low Back Pain/therapy , Magnetic Resonance Imaging/statistics & numerical data , Male , Ohio/epidemiology , Pain Measurement/statistics & numerical data , Prevalence , Prognosis , Radiculopathy/therapy , Treatment Outcome
14.
Pediatr Radiol ; 31(12): 836-40, 2001 Dec.
Article in English | MEDLINE | ID: mdl-11727016

ABSTRACT

BACKGROUND: Radiolucent foreign bodies (FBs) such as plastic objects and toys remain difficult to identify on conventional radiographs of the neck and chest. Children may present with a variety of respiratory complaints, which may or may not be due to a FB. OBJECTIVE: To determine whether radiolucent FBs such as plastic LEGOs and peanuts can be seen in the tracheobronchial tree or esophagus using low-dose spiral CT, and, if visible, to determine the optimal CT imaging technique. MATERIALS AND METHODS: Multiple spiral sequences were performed while varying the CT parameters and the presence and location of FBs in either the trachea or the esophagus first on a neck phantom and then a cadaver. Sequences were rated by three radiologists blinded to the presence of a FB using a single scoring system. RESULTS: The LEGO was well visualized in the trachea by all three readers (both lung and soft-tissue windowing: combined sensitivity 89 %, combined specificity 89 %) and to a lesser extent in the esophagus (combined sensitivity 31 %, combined specificity 100 %). The peanut was not well visualized (combined sensitivity < 35 %). The optimal technique for visualizing the LEGO was 120 kV, 90 mA, 3-mm collimation, 0.75 s/revolution, and 2.0 pitch. This allowed for coverage of the cadaver tracheobronchial tree (approximately 11 cm) in about 18 s. Although statistical power was low for detecting significant differences, all three readers noted higher average confidence ratings with lung windowing among 18 LEGO-in-trachea scans. CONCLUSION: Rapid, low-dose spiral CT may be used to visualize LEGO FBs in the airway or esophagus. Peanuts were not well visualized.


Subject(s)
Esophagus/diagnostic imaging , Foreign Bodies/diagnostic imaging , Tomography, X-Ray Computed/methods , Trachea/diagnostic imaging , Arachis , Cadaver , Female , Foreign Bodies/diagnosis , Humans , Phantoms, Imaging , Play and Playthings
15.
Ultrasound Med Biol ; 27(10): 1319-31, 2001 Oct.
Article in English | MEDLINE | ID: mdl-11731045

ABSTRACT

Spectral analysis of backscattered intravascular ultrasound (IVUS) data has demonstrated the ability to characterize plaque. We compared the ability of spectral parameters (e.g., slope, midband fit and y-intercept), computed via classic Fourier transform (CPSD), Welch power spectrum (WPSD) and autoregressive (MPSD) models, to classify plaque composition. Data were collected ex vivo from 32 human left anterior descending coronary arteries. Regions-of-interest (ROIs), selected from histology, comprised 64 collagen-rich, 24 fibrolipidic, 23 calcified and 37 calcified-necrotic regions. A novel quantitative method was used to correlate IVUS data with corresponding histologic sections. Periodograms of IVUS samples, identified for each ROI, were used to calculate spectral parameters. Statistical classification trees (CT) were computed with 75% of the data for plaque characterization. The remaining data were used to assess the accuracy of the CTs. The overall accuracies for normalized spectra with CPSD, WPSD and MPSD were, respectively, 84.7%, 85.6% and 81.1% (training data) and 54.1%, 64.9% and 37.8% (test data). These numbers were improved to 89.2%, 91.9% and 89.2% (training) and 62.2%, 73% and 59.5% (test) when the calcified and calcified-necrotic regions were combined for analysis. Most CTs misclassified a few fibrolipidic regions as collagen, which is histologically acceptable, and the unnormalized and normalized spectra results were similar.


Subject(s)
Algorithms , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Ultrasonography, Interventional/methods , Adult , Aged , Analysis of Variance , Cadaver , Calcium/analysis , Collagen/analysis , Coronary Artery Disease/pathology , Coronary Vessels/pathology , Humans , Middle Aged , Reference Values , Sensitivity and Specificity , Signal Processing, Computer-Assisted
16.
Stat Med ; 20(21): 3261-78, 2001 Nov 15.
Article in English | MEDLINE | ID: mdl-11746317

ABSTRACT

In evaluating the accuracy of diagnostic tests there are many situations where the true disease status can be one of multiple disorders. For example, when paediatric patients suffer acute abdominal pain, the underlying diagnosis could be appendicitis, intestinal obstruction, gastroenteritis, urinary tract infection, etc. In this paper we describe a format for collecting data for the case of multiple truth states. This new format allows one to make pairwise comparisons of the diagnostic accuracy between all of the different truth states. We propose a summary measure of accuracy which is a weighted average of the pairwise estimates of accuracy. Estimators are derived for the variance and covariance of the estimated summary accuracy. The small sample properties of the estimators are evaluated in a Monte Carlo simulation study. The new data collection format and summary measure were used in a paediatric acute abdominal pain study; data from this study are used to illustrate the methods.


Subject(s)
Abdomen, Acute/diagnosis , Abdomen, Acute/etiology , Biometry , Analysis of Variance , Appendicitis/diagnosis , Child , Diagnosis, Differential , Diagnostic Errors , Female , Gastroenteritis/diagnosis , Humans , Male , Monte Carlo Method , Urinary Tract Infections/diagnosis
17.
Eur Radiol ; 11(10): 1975-85, 2001.
Article in English | MEDLINE | ID: mdl-11702131

ABSTRACT

Recent promising trials that use low-dose CT for the early detection of lung cancer have reinvigorated the interest in screening approaches. At the same time the development of fast image acquisition techniques, such as multislice CT, have sparked renewed interest in cardiac imaging within the radiological community. In addition to special cardiac capabilities, multislice CT has several other features such as high acquisition speed and low-dose requirements that may make this modality a universal radiological screening tool. Non-invasive disease detection is the radiologist's domain. In this paper we identify criteria for effective screening and apply these criteria to screening approaches with multislice CT when used for detection of three disease entities: colon cancer; lung cancer; and cardiovascular disease.


Subject(s)
Colonic Neoplasms/diagnostic imaging , Coronary Disease/diagnostic imaging , Lung Neoplasms/diagnostic imaging , Tomography, X-Ray Computed/methods , Humans , Mass Screening
18.
Acad Radiol ; 8(10): 947-54, 2001 Oct.
Article in English | MEDLINE | ID: mdl-11699847

ABSTRACT

RATIONALE AND OBJECTIVES: In practice readers must often choose between multiple diagnoses. For assessing reader accuracy in these settings. Obuchowski et al have proposed the "differential diagnosis" method, which derives all pairwise estimates of accuracy for the various diagnoses, along with summary measures of accuracy. The current study assessed the correspondence between the differential diagnosis method and conventional binary-truth state experiments. MATERIALS AND METHODS: Two empirical studies were conducted at two institutions with different readers and diagnostic tests. Readers used the differential diagnosis format to interpret a set of cases. In subsequent readings they interpreted the cases in binary-truth state experiments. Spearman rank correlation coefficients and the percentages of agreement in scores were computed, and the areas under the receiver operating characteristic curves were estimated and compared. RESULTS: The between-format Spearman rank correlation coefficients were 0.697-0.718 and 0.750-0.780 for the two studies; the between-reader correlations were 0.417 and 0.792, respectively. The percentages of agreement between formats for the two studies were 50.0%-51.7% and 72.9%-78.8%; the percentages of agreement between readers were 45.0% and 80%, respectively. In the first study there were several significant differences in the areas under receiver operating characteristic curves; in the second study these differences were small. CONCLUSION: The differences observed between the two formats can be attributed to within-reader variability and inherent differences in the questions posed to readers in the multiple-diagnoses versus binary-truth state reading sessions. The differential diagnosis format is useful for estimating accuracy when there are multiple possible diagnoses.


Subject(s)
Diagnosis, Differential , Statistics as Topic , Confidence Intervals , ROC Curve
19.
Stat Med ; 20(19): 2845-63, 2001 Oct 15.
Article in English | MEDLINE | ID: mdl-11568944

ABSTRACT

Electronic medical images are an efficient and convenient format in which to display, store and transmit radiographic information. Before electronic images can be used routinely to screen and diagnose patients, however, it must be shown that readers have the same diagnostic performance with this new format as traditional hard-copy film. Currently, there exist no suitable definitions of diagnostic equivalence. In this paper we propose two criteria for diagnostic equivalence. The first criterion ('population equivalence') considers the variability between and within readers, as well as the mean reader performance. This criterion is useful for most applications. The second criterion ('individual equivalence') involves a comparison of the test results for individual patients and is necessary when patients are followed radiographically over time. We present methods for testing both individual and population equivalence. The properties of the proposed methods are assessed in a Monte Carlo simulation study. Data from a mammography screening study is used to illustrate the proposed methods and compare them with results from more conventional methods of assessing equivalence and inter-procedure agreement.


Subject(s)
Breast Neoplasms/diagnostic imaging , Diagnostic Imaging/methods , Mammography/methods , Signal Processing, Computer-Assisted , Breast Neoplasms/diagnosis , Computer Simulation , Confidence Intervals , Female , Humans , Middle Aged , Monte Carlo Method , ROC Curve , Random Allocation , Retrospective Studies , X-Ray Film
SELECTION OF CITATIONS
SEARCH DETAIL
...