Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Control Release ; 361: 847-855, 2023 09.
Article in English | MEDLINE | ID: mdl-37543291

ABSTRACT

Radionuclide imaging and therapy are promising methods for controlling systemic cancers; however, their clinical application has been limited by excessive radionuclide accumulation in healthy tissues. To minimize radionuclide accumulation in non-cancerous tissues while ensuring sufficient build up in tumors, we aimed to develop a method that controlled the in vivo dynamics of radionuclides post-administration. To this end, we describe a novel strategy that combines liposomes, a potent carrier system for drug delivery, with unique radionuclide-ligand complexes based on 111In-ethylenedicysteine. Conventional 111In-ligand-complexes-carrying liposomes delivered substantial amounts of radionuclides to tumors; however, they also accumulated in the liver and spleen. In contrast, 111In-ethylenedicysteine-carrying liposomes greatly reduced non-specific accumulation, while being retained selectively at high doses within tumors. Liposomes were rapidly broken down in the liver, releasing encapsulated 111In-ligand complexes. Among the chelates used, only 111In-ethylenedicysteine could escape from the liver and be excreted in the urine. Instead, most liposomes remained intact in tumors, retaining the radionuclide-ligand complexes within them. Therefore, high tumor accumulation was obtained regardless of the type of 111In-ligand complexes in the liposomes. In vivo single photon emission computed tomography/computed tomography imaging with 111In-ethylenedicysteine-carrying liposomes accurately revealed tumor-selective radionuclide retention with little background. Hence, our new strategy could greatly enhance tumor-to-healthy tissue ratios, improve diagnostic imaging, boost therapeutic efficacy, reduce toxicity to healthy tissues, and facilitate radionuclide imaging and therapy.


Subject(s)
Liposomes , Neoplasms , Humans , Ligands , Radioisotopes , Neoplasms/diagnostic imaging , Neoplasms/drug therapy
2.
Ann Nucl Med ; 26(1): 67-76, 2012 Jan.
Article in English | MEDLINE | ID: mdl-21987284

ABSTRACT

OBJECTIVES: Tumor interiors are never homogeneous and in vivo visualization of intratumoral heterogeneity would be an innovation that contributes to improved cancer therapy. But, conventional nuclear medicine tests have failed to visualize heterogeneity in vivo because of limited spatial resolution. Recently developed single photon emission computed tomographic (SPECT) scanners dedicated for small animal imaging are of interest due to their excellent spatial resolution of <1 mm, but few studies have focused on the evaluation of intratumoral heterogeneity. We investigated the optimal conditions related to high resolution imaging of heterogeneous tumor interiors using a small animal SPECT scanner. METHODS: The conditions related to SPECT/CT visualization of heterogeneous tumor interiors were investigated using phantoms with (111)In and simulations of actual small animal imaging. The optimal conditions obtained were validated by in vivo imaging of sarcoma 180-bearing mice. RESULTS: Larger number of counts must be obtained within limited acquisition time to visualize tumor heterogeneity in vivo in animal imaging, compared to cases that simply detect tumors. At an acquisition time of 30 min, better image quality was obtained with pinhole apertures diameter of 1.4 mm than of 1.0 mm. The obtained best spatial resolution was 1.3 mm, it was acceptable for our purpose, though a little worse than the best possible performance of the scanner (1.0 mm). Additionally, the reconstruction parameters, such as noise suppression, voxel size, and iteration/subset number, needed to be optimized under the limited conditions and were different from those found under the ideal condition. The minimal radioactivity concentration for visualization of heterogeneous tumor interiors was estimated to be as high as 0.2-0.5 MBq/mL. Liposomes containing (111)In met this requirement and were administered to tumor-bearing mice. SPECT imaging successfully showed heterogeneous (111)In distribution within the tumors in vivo with good spatial resolution. A threshold of 0.2 MBq/g for clear visualization of tumor heterogeneity was validated. Autoradiograms obtained ex vivo of excised tumors confirmed that the in vivo SPECT images accurately depicted the heterogeneous intratumoral accumulation of liposomes. CONCLUSION: Intratumoral heterogeneity was successfully visualized under the optimized conditions using a SPECT/CT scanner.


Subject(s)
Multimodal Imaging/methods , Positron-Emission Tomography , Sarcoma, Experimental/diagnostic imaging , Sarcoma, Experimental/pathology , Tomography, X-Ray Computed , Animals , Male , Mice , Multimodal Imaging/instrumentation , Phantoms, Imaging , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...