Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Chem ; 95(35): 12993-12997, 2023 Sep 05.
Article in English | MEDLINE | ID: mdl-37615663

ABSTRACT

In this study, we use nanopore arrays as a platform for detecting and characterizing individual nanoparticles (NPs) in real time. Dark-field imaging of nanopores with dimensions smaller than the wavelength of light occurs under conditions where trans-illumination is blocked, while the scattered light propagates to the far-field, making it possible to identify nanopores. The intensity of scattering increases dramatically during insertion of AgNPs into empty nanopores, owing to their plasmonic properties. Thus, momentary occupation of a nanopore by a AgNP produces intensity transients that can be analyzed to reveal the following characteristics: (1) NP scattering intensity, which scales with the sixth power of the AgNP radius, shows a normal distribution arising from the heterogeneity in NP size, (2) the nanopore residence time of NPs, which was observed to be stochastic with no permselective effects, and (3) the frequency of AgNP capture events on a 21 × 21 nanopore array, which varies linearly with the concentration of the NPs, agreeing with the frequency calculated from theory. The lower limit of detection (LOD) for NPs was 130 fM, indicating that the measurement can be used in applications in which ultrasensitive detection is required. The results presented here provide valuable insights into the dynamics of NP transport into and out of nanopores and highlight the potential of nanopore arrays as powerful, massively parallel tools for nanoparticle characterization and detection.

2.
ACS Sens ; 8(1): 270-279, 2023 01 27.
Article in English | MEDLINE | ID: mdl-36547518

ABSTRACT

We report a closed bipolar electrode (CBE)-based sensing platform for the detection of diagnostic metabolites in undiluted whole human blood. The sensor is enabled by electrode chemistry based on: (1) a mixed layer of blood-compatible adsorption-resistant phosphorylcholine (PPC) and phenylbutyric acid (PBA), (2) ferrocene (Fc) redox mediators, and (3) immobilized redox-active enzymes. This scheme is designed to overcome nonspecific protein adsorption and amplify sensing currents in whole human fluids. The scheme also incorporates a diffusing mediator to increase electronic communication between the immobilized redox enzyme and the working electrode. The use of both bound and freely diffusing mediators is synergistic in producing the electrochemical response. The sensor is realized by linking the analyte cell, containing the specific electrode surface architecture, through a CBE to a reporter cell containing the electrochromic reporter, methyl viologen (MV). The colorless-to-purple color change accompanying the 1e- reduction of MV2+ is captured using a smartphone camera. Subsequent red-green-blue analysis is performed on the acquired images to determine cholesterol, glucose, and lactate concentrations in whole blood. The CBE blood metabolite sensor produces a linear color change at clinically relevant concentration ranges for all metabolites with good reproducibility (∼5% or better) and with limits of detection of 79 µM for cholesterol, 59 µM for glucose, and 86 µM for lactate. Finally, metabolite concentration measurements from the CBE blood metabolite sensor are compared with results from commercially available FDA-approved blood cholesterol, glucose, and lactate meters, with an average difference of ∼3.5% across all three metabolites in the ranges studied.


Subject(s)
Biosensing Techniques , Blood Chemical Analysis , Humans , Biosensing Techniques/methods , Electrodes , Enzymes, Immobilized , Glucose , Lactic Acid , Paraquat , Reproducibility of Results , Blood Chemical Analysis/instrumentation
3.
ACS Meas Sci Au ; 1(2): 65-73, 2021 Oct 20.
Article in English | MEDLINE | ID: mdl-36785744

ABSTRACT

In this work, we develop a label-free electrochemical immunosensor for the detection of interleukin-6 (IL-6) in human cerebrospinal fluid (CSF) and serum for diagnostic and therapeutic monitoring. The IL-6 immunosensor is fabricated from gold interdigitated electrode arrays (IDEAs) that are modified with IL-6 antibodies for direct antigen recognition and capture. A rigorous surface analysis of the sensor architecture was conducted to ensure high structural fidelity and performance. Electrochemical characterization was conducted by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), and sensing was performed using differential pulse voltammetry (DPV). The DPV peak current was used to quantify IL-6 in buffer, CSF, and serum in the range 1 pg mL-1 < [IL-6] < 1 µg mL-1. The IL-6 IDEA sensor achieved a limit of detection (LOD) of 1.63 pg mL-1 in PBS, 2.34 pg mL-1 in human CSF, and 11.83 pg mL-1 in human serum. The sensor response is linear in the concentration range 10 pg mL-1 < [IL-6] < 10 ng mL-1, and the sensor is selective for IL-6 over other common cytokines, including IL-10 and TNF-α. EIS measurements showed that the resistance to charge transfer, R CT, decreases upon IL-6 binding, an observation attributed to a structural change upon Ab-Ag binding that opens up the architecture so that the redox probe can more easily access the electrode surface. The IL-6 IDEA sensor can be used as a point-of-care diagnostic tool to deliver rapid results (∼3 min) in clinical settings for traumatic brain injury, and potentially address the unmet need for effective diagnostic and prognostic tools for other cytokine-related illnesses, such as sepsis and COVID-19 induced cytokine storms. Given the interdigitated electrode form factor, it is likely that the performance of the sensor can be further improved through redox cycling.

4.
Analyst ; 144(21): 6240-6246, 2019 Nov 07.
Article in English | MEDLINE | ID: mdl-31538160

ABSTRACT

Enabled by the proliferation of nanoscale fabrication techniques required to create spatially-repeating, sub-wavelength structures to manipulate the behavior of visible-wavelength radiation, optical metamaterials are of increasing interest. Here we develop and characterize a chemical sensing approach based on electrochemical tuning of the optical response function of large-area, inexpensive nanoaperture metamaterials at visible and near-IR wavelengths. Nanosphere lithography is used to create an ordered array of sub-wavelength apertures in a Au film. The spacing of these apertures is established during fabrication, based on the size of the polystyrene nanospheres. Tunable shifts in the transmission spectrum can be produced post-fabrication by electrodeposition of a dissimilar metal, Ag, using the nanoaperture film as one electrode in a 2-electrode closed bipolar electrochemical (CBE) cell, altering hole size, film thickness, and film composition while maintaining hole spacing dictated by the original pattern. Optical transmission spectra acquired under galvanostatic conditions can be expressed as a linear combination of the initial and final (saturated) spectra, and the resulting response function exhibits a sigmoidal response with respect to the amount of charge (or metal) deposited. This architecture is then used to perform optical coulometry of model analytes in a CBE-based analyte-reporter dual cell device, thus expanding the capability of CBE-based sensors. Increasing the exposed electrode area of the analyte cell increases the response of the device, while modifying the circuit resistance alters the balance between sensitivity and dynamic range. These tunable nanoaperture metamaterials exhibit enhanced sensitivity compared to CBE electrochromic reporter cells to the µM to nM concentration range, suggesting further avenues for development of CBE-based chemical sensors as well as application to inexpensive, point-of-care diagnostic devices.

SELECTION OF CITATIONS
SEARCH DETAIL
...