Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 28
Filter
1.
Bioact Mater ; 34: 112-124, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38204564

ABSTRACT

Blood-contacting devices must be designed to minimize the risk of bloodstream-associated infections, thrombosis, and intimal lesions caused by surface friction. However, achieving effective prevention of both bloodstream-associated infections and thrombosis poses a challenge due to the conflicting nature of antibacterial and antithrombotic activities, specifically regarding electrostatic interactions. This study introduced a novel biocompatible hydrogel of sodium alginate and zwitterionic carboxymethyl chitosan (ZW@CMC) with antibacterial and antithrombotic activities for use in catheters. The ZW@CMC hydrogel demonstrates a superhydrophilic surface and good hygroscopic properties, which facilitate the formation of a stable hydration layer with low friction. The zwitterionic-functionalized CMC incorporates an additional negative sulfone group and increased negative charge density in the carboxyl group. This augmentation enhances electrostatic repulsion and facilitates the formation of hydration layer. This leads to exceptional prevention of blood clotting factor adhesion and inhibition of biofilm formation. Subsequently, the ZW@CMC hydrogel exhibited biocompatibility with tests of in vitro cytotoxicity, hemolysis, and catheter friction. Furthermore, in vivo tests of antithrombotic and systemic inflammation models with catheterization indicated that ZW@CMC has significant advantages for practical applications in cardiovascular-related and sepsis treatment. This study opens a new avenue for the development of chitosan-based multifunctional hydrogel for applications in blood-contacting devices.

2.
IEEE Trans Biomed Circuits Syst ; 17(5): 889-899, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37368797

ABSTRACT

This article presents a wireless and wearable body-pressure-monitoring system for the on-site, real-time prevention of pressure injuries for immobilized patients. For the prevention of pressure-induced skin injuries, a wearable pressure sensor system is designed to monitor the pressure at multiple sites on the skin and to alert the danger of prolonged application of pressure on the skin with a pressure-time integral (PTI) algorithm. The wearable sensor unit is developed using a pressure sensor based on a liquid metal microchannel and integrated with a flexible printed circuit board that includes a thermistor-type temperature sensor. The wearable sensor unit array is connected to the readout system board for the transmission of measured signals to a mobile device or PC via Bluetooth communication. We evaluate the pressure-sensing performances of the sensor unit and the feasibility of the wireless and wearable body-pressure-monitoring system through an indoor test and a preliminary clinical test at the hospital. It is shown that the presented pressure sensor has high-quality performance with excellent sensitivity to detect both high and low pressure. The proposed system measures the pressure at bony sites on the skin for about six hours continuously without any disconnection or failure, and the PTI-based alarming system operates successfully in the clinical setup. The system measures the pressure applied to the patient and provides meaningful information from the measured data for early diagnosis and prevention of bedsores to doctors, nurses, and healthcare workers.


Subject(s)
Skin , Wearable Electronic Devices , Humans , Early Diagnosis , Monitoring, Physiologic
3.
Small ; 19(32): e2206839, 2023 08.
Article in English | MEDLINE | ID: mdl-37069777

ABSTRACT

Peripheral nerve injuries cause various disabilities related to loss of motor and sensory functions. The treatment of these injuries typically requires surgical operations for improving functional recovery of the nerve. However, capabilities for continuous nerve monitoring remain a challenge. Herein, a battery-free, wireless, cuff-type, implantable, multimodal physical sensing platform for continuous in vivo monitoring of temperature and strain from the injured nerve is introduced. The thin, soft temperature, and strain sensors wrapped around the nerve exhibit good sensitivity, excellent stability, high linearity, and minimum hysteresis in relevant ranges. In particular, the strain sensor integrated with circuits for temperature compensation provides reliable, accurate strain monitoring with negligible temperature dependence. The system enables power harvesting and data communication to wireless, multiple implanted devices wrapped around the nerve. Experimental evaluations, verified by numerical simulations, with animal tests, demonstrate the feasibility and stability of the sensor system, which has great potential for continuous in vivo nerve monitoring from an early stage to complete regeneration.


Subject(s)
Electric Power Supplies , Prostheses and Implants , Animals , Temperature , Wireless Technology
4.
Small ; 19(9): e2205048, 2023 03.
Article in English | MEDLINE | ID: mdl-36534830

ABSTRACT

Repositioning is a common guideline for the prevention of pressure injuries of bedridden or wheelchair patients. However, frequent repositioning could deteriorate the quality of patient's life and induce secondary injuries. This paper introduces a method for continuous multi-site monitoring of pressure and temperature distribution from strategically deployed sensor arrays at skin interfaces via battery-free, wireless ionic liquid pressure sensors. The wirelessly delivered power enables stable operation of the ionic liquid pressure sensor, which shows enhanced sensitivity, negligible hysteresis, high linearity and cyclic stability over relevant pressure range. The experimental investigations of the wireless devices, verified by numerical simulation of the key responses, support capabilities for real-time, continuous, long-term monitoring of the pressure and temperature distribution from multiple sensor arrays. Clinical trials on two hemiplegic patients confined on bed or wheelchair integrated with the system demonstrate the feasibility of sensor arrays for a decrease in pressure and temperature distribution under minimal repositioning.


Subject(s)
Ionic Liquids , Wheelchairs , Humans , Temperature , Wireless Technology , Skin
5.
Small Methods ; 6(7): e2200248, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35507776

ABSTRACT

Three-dimensional (3D) hierarchical structures have been explored for various applications owing to the synergistic effects of micro- and nanostructures. However, the development of spherical micro/nano hierarchical structures (S-HSs), which can be used as energy/water harvesting systems and sensing devices, remains challenging owing to the trade-off between structural complexity and fabrication difficulty. This paper presents a new strategy for facile, scalable S-HS fabrication using a thermal expansion of microspheres and nanopatterned structures. When a specific temperature is applied to a composite film of microspheres and elastomers with nanopatterned surfaces, microspheres are expanded and 3D spherical microstructures are generated. Various nanopatterns and densities of spherical microstructures can thereby be quantitatively controlled. The fabricated S-HSs have been used in renewable electrical energy harvesting and sustainable water management applications. Compared to a triboelectric nanogenerator (TENG) with bare film, the S-HS-based TENG exhibited 4.48 times higher triboelectric performance with high mechanical durability. Furthermore, an S-HS is used as a water harvesting device to capture water in a fog environment. The water collection rate is dramatically enhanced by the increased surface area and locally concentrated vapor diffusion flux due to the spherical microstructures.

6.
Chem Eng J ; 440: 135830, 2022 Jul 15.
Article in English | MEDLINE | ID: mdl-35313452

ABSTRACT

Outbreaks of airborne pathogens pose a major threat to public health. Here we present a single-step nanocoating process to endow commercial face mask filters with photobiocidal activity, triboelectric filtration capability, and washability. These functions were successfully achieved with a composite nanolayer of silica-alumina (Si-Al) sol-gel, crystal violet (CV) photosensitizer, and hydrophobic electronegative molecules of 1H, 1H, 2H, 2H-perfluorooctyltriethoxysilane (PFOTES). The transparent Si-Al matrix strongly immobilized the photosensitizer molecules while dispersing them spatially, thus suppressing self-quenching. During nanolayer formation, PFOTES was anisotropically rearranged on the Si-Al matrix, promoting moisture resistance and triboelectric charging of the Si-Al/PFOTES-CV (SAPC)-coated filter. The SAPC nanolayer stabilized the photoexcited state of the photosensitizer and promoted redox reaction. Compared to pure-photosensitizer-coated filters, the SAPC filter showed substantially higher photobiocidal efficiency (∼99.99 % for bacteria and a virus) and photodurability (∼83 % reduction in bactericidal efficiency for the pure-photosensitizer filter but ∼0.34 % for the SAPC filter after 72 h of light irradiation). Moreover, after five washes with detergent, the SAPC filter maintained its photobiocidal and filtration performance, proving its reusability potential. Therefore, this SAPC nanolayer coating provides a practical strategy for manufacturing an antimicrobial and reusable mask filter for use during the ongoing COVID-19 pandemic.

8.
Sci Adv ; 7(42): eabj0694, 2021 Oct 15.
Article in English | MEDLINE | ID: mdl-34644113

ABSTRACT

Recently, three-dimensional electronics (3DE) is attracting huge interest owing to the increasing demands for seamless integration of electronic systems on 3D curvilinear surfaces. However, it is still challenging to fabricate 3DE with high customizability, conformability, and stretchability. Here, we present a fabrication method of 3DE based on predistorted pattern generation and thermoforming. Through this method, custom-designed 3DE is fabricated through the thermoforming process. The fabricated 3DE has high 3D conformability because the thermoforming process enables the complete replication of both the overall shape and the surface texture of the 3D mold. Furthermore, the usage of thermoplastic elastomer and a liquid metal­based conductive electrode allows for high thermoformability during the device fabrication as well as high stretchability during the device operation. We believe that this technology can enable a wide range of new functionalities and multiscale 3D morphologies in wearable electronics.

9.
Adv Mater ; 33(44): e2103974, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34510572

ABSTRACT

Continuous monitoring of vital signs is an essential aspect of operations in neonatal and pediatric intensive care units (NICUs and PICUs), of particular importance to extremely premature and/or critically ill patients. Current approaches require multiple sensors taped to the skin and connected via hard-wired interfaces to external data acquisition electronics. The adhesives can cause iatrogenic injuries to fragile, underdeveloped skin, and the wires can complicate even the most routine tasks in patient care. Here, materials strategies and design concepts are introduced that significantly improve these platforms through the use of optimized materials, open (i.e., "holey") layouts and precurved designs. These schemes 1) reduce the stresses at the skin interface, 2) facilitate release of interfacial moisture from transepidermal water loss, 3) allow visual inspection of the skin for rashes or other forms of irritation, 4) enable triggered reduction of adhesion to reduce the probability for injuries that can result from device removal. A combination of systematic benchtop testing and computational modeling identifies the essential mechanisms and key considerations. Demonstrations on adult volunteers and on a neonate in an operating NICUs illustrate a broad range of capabilities in continuous, clinical-grade monitoring of conventional vital signs, and unconventional indicators of health status.


Subject(s)
Monitoring, Physiologic
10.
Nat Commun ; 12(1): 5008, 2021 08 24.
Article in English | MEDLINE | ID: mdl-34429436

ABSTRACT

Capabilities for continuous monitoring of pressures and temperatures at critical skin interfaces can help to guide care strategies that minimize the potential for pressure injuries in hospitalized patients or in individuals confined to the bed. This paper introduces a soft, skin-mountable class of sensor system for this purpose. The design includes a pressure-responsive element based on membrane deflection and a battery-free, wireless mode of operation capable of multi-site measurements at strategic locations across the body. Such devices yield continuous, simultaneous readings of pressure and temperature in a sequential readout scheme from a pair of primary antennas mounted under the bedding and connected to a wireless reader and a multiplexer located at the bedside. Experimental evaluation of the sensor and the complete system includes benchtop measurements and numerical simulations of the key features. Clinical trials involving two hemiplegic patients and a tetraplegic patient demonstrate the feasibility, functionality and long-term stability of this technology in operating hospital settings.


Subject(s)
Biosensing Techniques , Electric Power Supplies , Pressure Ulcer , Pressure , Temperature , Wireless Technology , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Equipment Design , Monitoring, Physiologic , Skin , Thermography/instrumentation , Thermography/methods
12.
Adv Healthc Mater ; 10(4): e2000722, 2021 02.
Article in English | MEDLINE | ID: mdl-32989913

ABSTRACT

Eccrine sweat contains a rich blend of electrolytes, metabolites, proteins, metal ions, and other biomarkers. Changes in the concentrations of these chemical species can indicate alterations in hydration status and they can also reflect health conditions such as cystic fibrosis, schizophrenia, and depression. Recent advances in soft, skin-interfaced microfluidic systems enable real-time measurement of local sweat loss and sweat biomarker concentrations, with a wide range of applications in healthcare. Uses in certain contexts involve, however, physical impacts on the body that can dynamically deform these platforms, with adverse effects on measurement reliability. The work presented here overcomes this limitation through the use of microfluidic structures constructed in relatively high modulus polymers, and designed in geometries that offer soft, system level mechanics when embedded low modulus elastomers. Analytical models and finite element analysis quantitatively define the relevant mechanics of these systems, and serve as the basis for layouts optimized to allow robust operation in demanding, rugged scenarios such as those encountered in football, while preserving mechanical stretchability for comfortable, water-tight bonding to the skin. Benchtop testing and on-body field studies of measurements of sweat loss and chloride concentration under imposed mechanical stresses and impacts demonstrate the key features of these platforms.


Subject(s)
Microfluidics , Sweat , Electrolytes , Reproducibility of Results , Skin
13.
Nat Commun ; 11(1): 5990, 2020 11 25.
Article in English | MEDLINE | ID: mdl-33239608

ABSTRACT

Bioresorbable electronic stimulators are of rapidly growing interest as unusual therapeutic platforms, i.e., bioelectronic medicines, for treating disease states, accelerating wound healing processes and eliminating infections. Here, we present advanced materials that support operation in these systems over clinically relevant timeframes, ultimately bioresorbing harmlessly to benign products without residues, to eliminate the need for surgical extraction. Our findings overcome key challenges of bioresorbable electronic devices by realizing lifetimes that match clinical needs. The devices exploit a bioresorbable dynamic covalent polymer that facilitates tight bonding to itself and other surfaces, as a soft, elastic substrate and encapsulation coating for wireless electronic components. We describe the underlying features and chemical design considerations for this polymer, and the biocompatibility of its constituent materials. In devices with optimized, wireless designs, these polymers enable stable, long-lived operation as distal stimulators in a rat model of peripheral nerve injuries, thereby demonstrating the potential of programmable long-term electrical stimulation for maintaining muscle receptivity and enhancing functional recovery.


Subject(s)
Absorbable Implants , Electric Stimulation Therapy/instrumentation , Peripheral Nerve Injuries/therapy , Polyurethanes/chemistry , Wireless Technology/instrumentation , Animals , Disease Models, Animal , Electric Stimulation Therapy/methods , Female , Humans , Materials Testing , Muscle, Skeletal/innervation , Muscle, Skeletal/physiology , Rats , Regeneration , Sciatic Nerve/injuries , Sciatic Nerve/physiology
14.
Proc Natl Acad Sci U S A ; 117(45): 27906-27915, 2020 11 10.
Article in English | MEDLINE | ID: mdl-33106394

ABSTRACT

Soft microfluidic systems that capture, store, and perform biomarker analysis of microliter volumes of sweat, in situ, as it emerges from the surface of the skin, represent an emerging class of wearable technology with powerful capabilities that complement those of traditional biophysical sensing devices. Recent work establishes applications in the real-time characterization of sweat dynamics and sweat chemistry in the context of sports performance and healthcare diagnostics. This paper presents a collection of advances in biochemical sensors and microfluidic designs that support multimodal operation in the monitoring of physiological signatures directly correlated to physical and mental stresses. These wireless, battery-free, skin-interfaced devices combine lateral flow immunoassays for cortisol, fluorometric assays for glucose and ascorbic acid (vitamin C), and digital tracking of skin galvanic responses. Systematic benchtop evaluations and field studies on human subjects highlight the key features of this platform for the continuous, noninvasive monitoring of biochemical and biophysical correlates of the stress state.


Subject(s)
Biosensing Techniques/instrumentation , Microfluidics/methods , Sweat/chemistry , Dielectric Spectroscopy/instrumentation , Dielectric Spectroscopy/methods , Electric Impedance , Equipment Design/instrumentation , Equipment Design/methods , Fluorometry , Humans , Immunoassay , Lab-On-A-Chip Devices , Skin/chemistry , Wearable Electronic Devices
15.
Sci Adv ; 6(35): eabb1093, 2020 08.
Article in English | MEDLINE | ID: mdl-32923633

ABSTRACT

Implantable drug release platforms that offer wirelessly programmable control over pharmacokinetics have potential in advanced treatment protocols for hormone imbalances, malignant cancers, diabetic conditions, and others. We present a system with this type of functionality in which the constituent materials undergo complete bioresorption to eliminate device load from the patient after completing the final stage of the release process. Here, bioresorbable polyanhydride reservoirs store drugs in defined reservoirs without leakage until wirelessly triggered valve structures open to allow release. These valves operate through an electrochemical mechanism of geometrically accelerated corrosion induced by passage of electrical current from a wireless, bioresorbable power-harvesting unit. Evaluations in cell cultures demonstrate the efficacy of this technology for the treatment of cancerous tissues by release of the drug doxorubicin. Complete in vivo studies of platforms with multiple, independently controlled release events in live-animal models illustrate capabilities for control of blood glucose levels by timed delivery of insulin.

16.
Langmuir ; 36(30): 8939-8946, 2020 08 04.
Article in English | MEDLINE | ID: mdl-32610911

ABSTRACT

Soft strain sensors have attracted significant attention in wearable human motion monitoring applications. However, there is still a huge challenge for decoupled measurement of multidirectional strains. In this study, we have developed a biaxial and stretchable strain sensor based on a carbon nanotube (CNT) film and a microdome array (MA)-patterned elastomeric substrate. The MA structures lead to generating localized and directional microcracks of CNT films within the intended regions under tensile strain. This mechanism allows a single sensing layer to act as a strain sensor capable of decoupling the biaxial strains into axial and transverse terms. The ratio of resistance change between two perpendicular axes is about 960% under an x-directional strain of 30%, demonstrating the biaxial decoupling capability. Also, the proposed strain sensor shows high stretchability and excellent long-term reliability under a cyclic loading test. Finally, wearable devices integrated with the strain sensor have been successfully utilized to monitor various human motions of the wrist, elbow, knee, and fingers by measuring joint bending and skin elongation.


Subject(s)
Nanotubes, Carbon , Wearable Electronic Devices , Humans , Motion , Reproducibility of Results
18.
Lab Chip ; 20(1): 84-92, 2020 01 07.
Article in English | MEDLINE | ID: mdl-31776526

ABSTRACT

Eccrine sweat is a rich and largely unexplored biofluid that contains a range of important biomarkers, from electrolytes, metabolites, micronutrients and hormones to exogenous agents, each of which can change in concentration with diet, stress level, hydration status and physiologic or metabolic state. Traditionally, clinicians and researchers have used absorbent pads and benchtop analyzers to collect and analyze the biochemical constituents of sweat in controlled, laboratory settings. Recently reported wearable microfluidic and electrochemical sensing devices represent significant advances in this context, with capabilities for rapid, in situ evaluations, in many cases with improved repeatability and accuracy. A limitation is that assays performed in these platforms offer limited control of reaction kinetics and mixing of different reagents and samples. Here, we present a multi-layered microfluidic device platform with designs that eliminate these constraints, to enable integrated enzymatic assays with demonstrations of in situ analysis of the concentrations of ammonia and ethanol in microliter volumes of sweat. Careful characterization of the reaction kinetics and their optimization using statistical techniques yield robust analysis protocols. Human subject studies with sweat initiated by warm-water bathing highlight the operational features of these systems.


Subject(s)
Alcohol Oxidoreductases/metabolism , Ammonia/analysis , Ethanol/analysis , Horseradish Peroxidase/metabolism , Lab-On-A-Chip Devices , Sweat/chemistry , Ammonia/metabolism , Ethanol/metabolism , Healthy Volunteers , Humans , Kinetics , Sweat/metabolism
19.
ACS Appl Mater Interfaces ; 11(26): 23639-23648, 2019 Jul 03.
Article in English | MEDLINE | ID: mdl-31180635

ABSTRACT

Flexible and wearable pressure sensors have attracted a tremendous amount of attention due to their wider applications in human interfaces and healthcare monitoring. However, achieving accurate pressure detection and stability against external stimuli (in particular, bending deformation) over a wide range of pressures from tactile to body weight levels is a great challenge. Here, we introduce an ultrawide-range, bending-insensitive, and flexible pressure sensor based on a carbon nanotube (CNT) network-coated thin porous elastomer sponge for use in human interface devices. The integration of the CNT networks into three-dimensional microporous elastomers provides high deformability and a large change in contact between the conductive CNT networks due to the presence of micropores, thereby improving the sensitivity compared with that obtained using CNT-embedded solid elastomers. As electrical pathways are continuously generated up to high compressive strain (∼80%), the pressure sensor shows an ultrawide pressure sensing range (10 Pa to 1.2 MPa) while maintaining favorable sensitivity (0.01-0.02 kPa-1) and linearity ( R2 ∼ 0.98). Also, the pressure sensor exhibits excellent electromechanical stability and insensitivity to bending-induced deformations. Finally, we demonstrate that the pressure sensor can be applied in a flexible piano pad as an entertainment human interface device and a flexible foot insole as a wearable healthcare and gait monitoring device.


Subject(s)
Biosensing Techniques , Elastomers/chemistry , Nanotubes, Carbon/chemistry , Wearable Electronic Devices , Elastomers/therapeutic use , Electric Conductivity , Humans , Porosity , Pressure
20.
ACS Nano ; 13(10): 10972-10979, 2019 10 22.
Article in English | MEDLINE | ID: mdl-31124670

ABSTRACT

Sensors that reproduce the complex characteristics of cutaneous receptors in the skin have important potential in the context of artificial systems for controlled interactions with the physical environment. Multimodal responses with high sensitivity and wide dynamic range are essential for many such applications. This report introduces a simple, three-dimensional type of microelectromechanical sensor that incorporates monocrystalline silicon nanomembranes as piezoresistive elements in a configuration that enables separate, simultaneous measurements of multiple mechanical stimuli, such as normal force, shear force, and bending, along with temperature. The technology provides high sensitivity measurements with millisecond response times, as supported by quantitative simulations. The fabrication and assembly processes allow scalable production of interconnected arrays of such devices with capabilities in spatiotemporal mapping. Integration with wireless data recording and transmission electronics allows operation with standard consumer devices.


Subject(s)
Biosensing Techniques , Physical Phenomena , Skin/metabolism , Touch/physiology , Electronics , Mechanical Phenomena , Skin/chemistry , Temperature , Touch/genetics
SELECTION OF CITATIONS
SEARCH DETAIL
...